MAURY USCG vessel records
← All vessels

LUXCAT

LUXCAT is a 2023 passenger vessel (inspected). The Coast Guard has recorded 6 inspections since 2023, most recently in May 2026, along with 2 deficiencies.

Records from 2023 to 2026. Most recent: inspection, 4 May 2026.

Built
2023
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 May 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN7316
1763176
Flag
UNITED STATES
Maury page id
psix-1763176

Documentation record

Registered dimensions (L × B × D)52.0 ft × 16.7 ft × 3.0 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA&M MANUFACTURING INC · ALACHUA, FL, UNITED STATES · built 2023
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTri Hull
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

4 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8361789
14 May 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8136373
20 February 2025 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8082134
22 May 2024 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7917067
2 May 2023 Construction Oversight · Administrative Inspection · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7679394
28 March 2023 Construction Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7658356

Deficiency record · 2

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 May 2026 Resolved
A loading mark required by paragraph (c)(2) of this section must be a horizontal line of at least 205 millimeters (8 inches) in length and 25 millimeters (1 inch) in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint. Loading mark not affixed on the vessel per stability letter.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 28 May 2026
Resolution: Vessel provided photo of corrected deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Flame screens missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 28 May 2026
Resolution: Vessel provided photo of corrected deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.