This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it12477 - Convention (Subpart B), Gross Ton 9575 - Dead Weight, Metric Ton 16507 - Displacement, Metric Ton 3744 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
13 January 2023Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7621367
6 January 2023PSC A · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7617595
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 13 January 2023Resolved
The company should establish procedures to ensure that new personnel and personnel transferred to new assignments related to safety and protections of the environment are given proper familiarization with their duties. Instructions which are esential to be provided prior to sailing should be identified, documented and given. PSCO observed vessel following incorrect procedures for testing high and overflow alarms, high and low pressure and fixed gas detection.
74 SOLAS (20) IX/3.1
ISM Code A/6.3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2023
Resolved 14 January 2023
Resolution: Recieved class report attesting to proper implementation of procedures. Reveiewed and found satisfactory.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.