Records from 2023 to 2025. Most recent: inspection, 8 October 2025.
Inspection history · 4
8 October 2025
PSC B · Administrative Inspection · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8244011
31 July 2024
PSC B · COC-CHEM & TVE Renew · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7965851
8 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7822294
14 March 2023
PSC A · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650712
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 8 October 2025
Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. PSCO observed the flame screen for the P/V breaker to be wasted.
74 SOLAS (20) II-2/4.5.3.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 January 2026
Resolved 21 January 2026
Resolution: Received DNV Class Report attesting to satisfactory replacement of P/V Breaker flame screen.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 31 July 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2024
Resolution: VESSEL ACQUIRED APPROPIATE SPAN GAS TO PROPERTLY CONDUCT HIGH ALARM SET OINTS OF LEL SENSORS. CLASS STATEMENT WAS RECIEVED. DEF CLEARED
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 July 2024
Resolved
THE INSPECTION AND MAINTANANCE OF ELECTRICAL INSTALLATIONS IN EXPLOSION HAZARD SPACES SHALL BE PERFORMED IN ACCORDANCE WITH RECOGIZED STANDARDS. PSCO OBSERVED NUMEROUS CABLE GLANDS IN THE HAZEROUS AREAS THAT WERE INPROPERLY INSTALLED. SOLAS(2020) II-1/57 40A/C MSC./CIRC.1621.17.3.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2024
Resolution: CLASS STATEMENT FROM DNV ATTESTED TO THE CORRECTION
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 July 2024
Resolved
IN THE BUNKEING LINE, AS CLOSE TO THE CONNECTION POINT AS POSSIBLE , THERE SHOULD BE AN MANUALY OPERATED STOP VALVE AND A REMOTELY OPERATED SHUTDOWN VALVE ARRANGED IN SERIES. ALTERNATIVILY, A COMBINED MANUALLY OPERATED AND REMOTE SHUTDOWN VALVE MAYBE PROVIDED. PSCO OBSERVED THAT VESSEL DIDNT MATCH THE RE3QUIREMENTS STATED IN 8.5.4. PROVDE DOCUMENTARY PROOF AS TO CORRENT ARRANMENT.SOLA(2020) II-1/57 MSC.1/CIRC,1621 8.5.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 August 2024
Resolution: Vessel representative sent documentation of alternative arrangement as DNV LFL notation in lieu of SOLAS IGF code Pt. A 2.3. Documentation has been added to the vessel documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 July 2024
Resolved
THE INSPCTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN EXPLOSION HAZARDOUS SPACES SHOLD BE PREFORMED IN ACCORDANCE WITH RECOGNIZED STANDORDS. PSCO OBSERVED THAT NO CREWMEMBERS HOLDS CERTIFICATION TO PREFORM MAINTENACE ON ELECTICAL EQUIPMENT IN ACCORDANCE WITH THE RECOGNIZED STANDARDS. SOLAS(2020) II-1/57 MSC.1/CIRC. 1621 17.3.2 40 A/C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2024
Resolution: COMPANY REP FOR THE VESSEL enrolled the ETO on a e-learning course which covers the IEC requirements which have been referred to and recognised by Class.