MAURY USCG vessel records Sign in
← All vessels

CMA CGM ARISTOTE

CMA CGM ARISTOTE is a 2007 freight ship. The Coast Guard has recorded 14 inspections since 2023, most recently in April 2026, along with 6 deficiencies and 2 operational controls.

Records from 2023 to 2026. Most recent: inspection, 24 April 2026.

Built
2007
Last inspected
24 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9360154 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA4981
1765673
Flag
MALTA
—
Maury page id
psix-1765673

Inspections, by type

…with no type recorded3
Years with a record 4 calendar years (2023–2026)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it17594 - Convention (Subpart B), Gross Ton
7181 - Convention (Subpart B), Net Ton
17594 - Regulatory (Subpart C or D), Gross Ton
21267 - Dead Weight, Metric Ton
28986 - Displacement, Metric Ton
7181 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

24 April 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8355406
10 February 2026 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8308725
4 February 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8305935
21 January 2026 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8298384
20 January 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8298927
27 December 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8287561
9 October 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8250074
5 October 2025 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8244221
25 March 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8099137
15 October 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8019178
22 September 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8006991
17 March 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7880414
1 February 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7858997
17 February 2023 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7638208

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 January 2026 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILBLE FOR USE. PSCO OBSERVED THE ANNUAL GALLEY FIRE SYSTEM INSPECTION STATED THE WRONG HOSES ARE INSTALLLED AND ARE IN NEED OF REPLACEMENT 74 SOLAS (09) II-2/14.2.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 February 2026
Resolution: Class report recieved
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 January 2026 Resolved
A FIXED FIRE-FIGHTING SYSTEM COMPLYING WITH THE PROVISIONS OF THE FIRE SAFETY SYSTEMS CODE. TWO SEPARATE CONTROLS SHALL BE PROVIDED FOR RELEASING CARBON DIOXIDE INTO A PROTECTED SPACE. PSCO OBSERVED 01 PILOT BOTTLE IN CO2 ROOM EMPTY 74 SOLAS (09) II-2/10.4.1.1 FSS CODE CH.5/2.2.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 February 2026
Resolution: Class report recieved.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 October 2025 Resolved
The purpose of this regulation is to contain a fire in the space of origin. The fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed openings in fire door at port side ER. 74 SOLAS (09) II-2/9.1.3
Action required: 15 - Rectify deficiencies by next port
Resolved 29 October 2025
Resolution: Recieved class reports
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 October 2025 Resolved
A food ration not less than 10000KJ for each person lifeboat is permitted to accomodate is required. STBD lifeboat food rations are expired. 74SOLAS(20) III/13.4 LSA Code 4.4.8.12
Action required: 15 - Rectify deficiencies by next port
Resolved 29 October 2025
Resolution: Recieved class reports
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 October 2025 Resolved
The condition of the ship shall be maintained to conform with the provisions of the present regulations. PSCO observed inset on stbd quarter of the vessel. 74SOLAS(20)I/11.a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2025
Resolved 29 October 2025
Resolution: Recieved class reports
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. PSCO observed electrical wiring for 04 port side super structure lights exposed and corred. Additionally, PSCO observed piping for electrical installations on deck worn through with the weight of the pipe only being supported by the electrical wires. 74Solas(2009) II-1/45.5.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2025
Resolution: Vessel sent class report to clear def.

Ownership record