Records from 2023 to 2025. Most recent: inspection, 10 June 2025.
Inspection history · 4
10 June 2025
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8080352
23 August 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7976104
19 April 2023
Initial Certification · Drydock Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7671936
30 January 2023
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7633120
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 August 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. MI observed stowage for adult life jackets not labeled with size and quantity.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 10 September 2024
Resolution: All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 August 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. MI observed stowage for child life jackets not labeled with size and quantity.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 10 September 2024
Resolution: All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 August 2024
Resolved
Openings in the side of a vessel below the bulkhead or weather deck must be labeled at the operating point for identity and direction of closing. MI observed bilge overboard shutoff valve not labeled.
46 CFR 179.350(e)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 10 September 2024
Resolution: All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. Vessel failed to contact OCMI to undergo annual inspection prior to 25AUG2023. 46 CFR 176.500(b)(1) 10c
Action required: 10 - Deficiency Rectified
Due 23 August 2024
Resolved 23 August 2024
Resolution: Annual inspection completed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Stowage locations for adult and child life jackets not marked. Provide adequate markings for the stowage location of each life jacket type. 46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2023
Resolved 3 May 2023
Resolution: Received photos of labeled storage, all sat.