← All vessels
QUINCY
QUINCY is a 2008 towing vessel. The Coast Guard has recorded 4 inspections since 2023, most recently in May 2026, along with 12 deficiencies.
Records from 2023 to 2026. Most recent: inspection, 7 May 2026.
- Built
- 2008
- Last inspected
- 7 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
AEOR
1767682
Flag
UNITED STATES
—
Maury page id
psix-1767682
Inspections, by type
Years with a record
4 calendar years (2023–2026)
The 4 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it503 - Simplified, Gross Ton
571 - Displacement, Ton
503 - Convention (Subpart B), Gross Ton
571 - Displacement, Ton
503 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 4
7 May 2026
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8368182
7 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8251881
11 September 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7997758
5 June 2023
Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7703903
Deficiency record · 12
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2025
Resolved
Nonconductive mats or grating must be provided on the deck in front of each switchboard and, if it is accessible from the rear, on the deck behind the switchboard. Numerous high voltage switchboards and electrical panels in engine room do not have nonconductive mats provided. 46 CFR 143.560(c)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2025
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Towing gear inspections are not being logged as required. 46 CFR 140.820(b)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2025
Resolved
Flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use...A 40-B portable fire extinguisher must be located near the storage room or cabinet. Combustible liquids are being stowed in a room on the main deck without a fire extinguisher nearby.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 September 2024
Resolved
Fixed fire-extinguishing system: (1) A carbon dioxide system that meets the requirements of 46 CFR sub part 76.15 and 46 CFR 78.47-9 and 78.47-11, and that is approved by the commandant...
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. Each control valve to branch lines must be marked to indicate the related space served.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 June 2023
Resolved
Flexible connections and discharge hoses on all fixed extinguishing systems must be inspected and tested in accordance with § 147.65 of this chapter. CO2 hoses failed most recent inspection. Replace hoses.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 June 2023
Resolved
All piping each fixed fire-extinguishing system must be tested, to determine that the system is operating properly. Conduct air test on fixed fire system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2023
Resolved
A 40–B portable fire extinguisher must be located near the flammable storage room or cabinet. Extinguisher was not near flam cabinet on deck.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 June 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: Automatic, battery-operated with a duration of no less than 2 hours; or Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Berthing spaces did not have lights and the light in shaft alley inop.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 June 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Cap or remove wires that are not in use.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 7 June 2023
Resolved
Each emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 June 2023
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. At a minimum, this assessment must consider the items listed in 46 CFR 140.635.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 June 2023
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. The gaskets on the hatch cover to the deck voids were wasted. Replace gaskets.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.