Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it503 - Simplified, Gross Ton 571 - Displacement, Ton 503 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
4 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2025Resolved
Nonconductive mats or grating must be provided on the deck in front of each switchboard and, if it is accessible from the rear, on the deck behind the switchboard. Numerous high voltage switchboards and electrical panels in engine room do not have nonconductive mats provided. 46 CFR 143.560(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 21 January 2026
Resolution: Mats have been installed in front of panels
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Towing gear inspections are not being logged as required. 46 CFR 140.820(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 21 January 2026
Resolution: Implemented towing gear records on vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2025Resolved
Flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use...A 40-B portable fire extinguisher must be located near the storage room or cabinet. Combustible liquids are being stowed in a room on the main deck without a fire extinguisher nearby.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 21 January 2026
Resolution: Flammabel Liquids are removed from lockers.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 September 2024Resolved
Fixed fire-extinguishing system: (1) A carbon dioxide system that meets the requirements of 46 CFR sub part 76.15 and 46 CFR 78.47-9 and 78.47-11, and that is approved by the commandant...
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. Each control valve to branch lines must be marked to indicate the related space served.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 4 October 2024
Resolution: Instructions provided
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 June 2023Resolved
Flexible connections and discharge hoses on all fixed extinguishing systems must be inspected and tested in accordance with § 147.65 of this chapter. CO2 hoses failed most recent inspection. Replace hoses.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2023
Resolved 15 June 2023
Resolution: GETZ fire replaced hoses 13jun2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 June 2023Resolved
All piping each fixed fire-extinguishing system must be tested, to determine that the system is operating properly. Conduct air test on fixed fire system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 15 June 2023
Resolution: conducted air test 06jun2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2023Resolved
A 40–B portable fire extinguisher must be located near the flammable storage room or cabinet. Extinguisher was not near flam cabinet on deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 15 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 June 2023Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: Automatic, battery-operated with a duration of no less than 2 hours; or Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Berthing spaces did not have lights and the light in shaft alley inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 15 June 2023
Resolution: used tape
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 June 2023Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Cap or remove wires that are not in use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 15 June 2023
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 7 June 2023Resolved
Each emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 15 June 2023
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. At a minimum, this assessment must consider the items listed in 46 CFR 140.635.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 22 June 2023
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. The gaskets on the hatch cover to the deck voids were wasted. Replace gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 28 June 2023