MORTON HENSHAW

MORTON HENSHAW is a 1979 towing vessel. The Coast Guard has recorded 11 inspections since 2011, most recently in July 2026, along with 7 deficiencies.

Records from 2011 to 2026. Most recent: inspection, 27 July 2026.

Built
1979
Last inspected
27 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTC6597
176861
Flag
UNITED STATES
367336340
Maury page id
psix-176861

Inspections, by type

Years with a record 8 calendar years (2011–2026)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 20.5 ft × 7.0 ft
Registered tonnagegross 69 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · GUILD · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 November 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Net Ton
69 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WTC6597MMSI 367336340 · active · compulsorily equipped · granted 22 February 2018, expires 5 May 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 11

27 July 2026 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8443262
21 October 2024 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8020455
23 August 2023 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7775984
26 October 2022 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7575744
19 August 2021 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7291342
3 August 2020 Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7023173
31 August 2015 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5231146
5 February 2015 Industry Initiated Exam · Administration · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5065026
8 September 2011 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4139178
26 July 2011 Industry Initiated Exam · MTSA Verification · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4101744
30 March 2011 Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3980990

Deficiency record · 7

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 October 2022 Resolved
Each lifebuoy that is required to have a light the light must be secured around the body of the lifebuoy. All lights were secured around the lifebuoy line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2022
Resolved 28 November 2022
Resolution: All lights have been secured around the body of lifebuoy.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 October 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. There was excess oil accumulation in the bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2022
Resolved 28 November 2022
Resolution: All excess oil has been cleaned from the bilges.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 July 2021 Resolved
The design of the fire detection system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience. Provide evidence of such.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 July 2021 Resolved
The fire detection system must draw power from two sources. the battery's for the FDS were not operable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 19 August 2021
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 July 2021 Resolved
Alarms must: Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. Vessels alarm at the operating station was not able to be heard over the vessels normal operating noise. Install adequate speaker to the satisfaction of attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 20 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 July 2021 Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, and fixed fire-extinguishing systems required by this part must be approved by the Commandant (CG-ENG). Where other equipment in this part is required to be approved, such equipment requires the specific approval of the Commandant. Portable fire extinguisher on the 2nd deck, near the flammable storage locker was not in an approved bracket. Make repairs to the satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2021 Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen. The flame screen on the bow vent had too large of mesh.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 19 August 2021

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.