Records from 2023 to 2026. Most recent: inspection, 6 July 2026.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 6 July 2026
Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed leaking steam trace line in engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 July 2026
Resolution: Crew was able to stop the steam leak while PSCO on board.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 6 December 2024
Resolved
The condition of the ship and it's equipment shall be maintained to ensure the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO observed evidence of a leak near and above the generators. PSCO discovered crew had a leak on the open loop residence tank. Crew completed a reapair, but failed to notify C/E, Master, Company, Flag, or Class.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2024
Resolution: Please see class report in documents tab for more information. Issued condition of class to give time for permanent repairs to be done. Temporary repairs verified by class surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 6 December 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and operational nature of deficiency No. 1 provide objective evidence of a failure or lack of effectiveness of the implementation of the ISM code. An internal safety audit and is required and corrective action within three months.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 December 2024
Resolution: Please see class report in documents tab for mor einformation. Vessel completed internal safety audit.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 1 May 2023
Resolved
Plans and booklets shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. PSCO observed two fire doors not listed in the fire control plan. One door is in the steering gear room. The second door is a door to the purifier room.
74 SOLAS (20) II-2/15.2.4.1
40ac
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 August 2023
Resolved 6 June 2023
Resolution: Vessel provided an updated fire control plan.