HS AYSE ANA

HS AYSE ANA is a 2007 tank ship. The Coast Guard has recorded 2 inspections since 2023, most recently in December 2024, along with 6 deficiencies — 3 with no resolution recorded —.

Records from 2023 to 2024. Most recent: inspection, 23 December 2024.

Built
2007
Last inspected
23 December 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 December 2024
…past their stated due date3
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2023–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9379478
9HA5681
1769394
Flag
MALTA
Maury page id
psix-1769394

Documentation record

Tonnage as PSIX records it3269 - Convention (Subpart B), Gross Ton
4726 - Dead Weight, Ton
1452 - Convention (Subpart B), Net Ton
6771 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

23 December 2024 COC-CHEM & TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8050489
13 April 2023 COC-CHEM & TVE Renew · PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7666063

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2024 No resolution recorded
Eletrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO observed O2 damaged explosion proof lights in heat exchanger room and 01 damaged explosion proof lights over 6S tank dome. 74 SOLAS (20) VII/10, IBC 10.1.2.1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2025 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 13 April 2023 No resolution recorded
Ships carrying toxic or flammable products or both shall be equipped with at least two instruments designed and calibrated for testing the specific vapours in question. If such instruments are not capable of testing for both toxic concentrations and flammable concentrations, then two separate sets of instruments shall be provided. Vessel does not have proper tubes for detection equipment on board to be able to test for toxic vapours.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 April 2023 Resolved
Electrical equipment cables and wiring shall not be installed in the hazardous locations unless it conforms with the standards not inferior to those acceptable to the Organization. Electrical wiring was exposed on explosion proof light fixture above #6 starboard cargo tank.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 April 2023
Resolved 13 April 2023
Resolution: Vessel fixed electrical fixture.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 13 April 2023 No resolution recorded
A tank overflow control system required by this section shall come into operation when the normal tank loading procedures fail to stop the tank liquid level exceeding the normal full condition and give a visual and audible tank overflow alarm to the ships operator. The #6 starboard tank overfill audible and visual alarm are not functioning.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 April 2023 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. One vapor connection line on port and starboard side are missing the permanent stud.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 April 2023
Resolved 13 April 2023
Resolution: Vessel fixed vapor control connection to have permanent outward projecting stud.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 13 April 2023 Resolved
The master, owner, operator, agent, or person in charge of a vessel subject to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC) by electronic ballast water report format using methods specified at NBIC's Web site. Vessel failed to submit a ballast water report to the NBIC 6 hours after entering port.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 April 2023
Resolved 13 April 2023
Resolution: Master submitted ballast water report to the NBIC during the exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.