MAURY USCG vessel records Sign in
← All vessels

MARINE PACIFIC

MARINE PACIFIC is a 1979 tank ship. The Coast Guard has recorded 35 inspections since 1991, most recently in June 2000, along with 34 deficiencies.

Records from 1991 to 2000. Most recent: inspection, 16 June 2000.

Built
1979
Last inspected
16 June 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7417460 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
176966
Flag
UNITED STATES
—
Maury page id
psix-176966

Inspections, by type

…with no type recorded16
Years with a record 9 calendar years (1991–2000)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it158576 - Convention (Subpart B), Net Ton
192707 - Convention (Subpart B), Gross Ton
450684 - Displacement, Ton
404538 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 35

16 June 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 278960
11 February 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 425459
17 November 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 410131
17 November 1997 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1108876
10 September 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 394782
29 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192741
10 June 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 379430
10 May 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 879598
6 May 1994 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1455162
23 February 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853746
18 August 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844878
11 August 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153885
6 June 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844592
18 December 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1134452
29 September 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264276
17 September 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263711
4 September 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 159034
2 September 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 681415
27 August 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1263614
14 August 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 681412
11 August 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 62718
11 August 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1251073
6 August 1992 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 940661
8 July 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182554
16 June 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 945257
4 May 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 942945
10 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1256659
5 February 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 946218
22 January 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319243
25 December 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 135280
21 December 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 120661
22 November 1991 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248270
21 October 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253458
7 August 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933645
22 July 1991 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1247122

Deficiency record · 34

Construction/Loadline
Issued 10 September 1996 Resolved
PRIOR TO LOADING CARGO, MAKE PERMANENT REPAIRS TO BALLAST SYSTEM. DURING INTERIM, MAINTAIN ISOLATION OF FAULTY PIPING AND DO NOT OPERATE BALLAST SYSTEM. HAVE CLASSIFICATION SOCIETY PROVIDE EVIDENCE OF PERMANENT REPAIR.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Navigation
Issued 10 June 1995 Resolved
RECORDER FOR ECHO SOUNDING DEVICE NOT WORKING.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Engineering
Issued 10 June 1995 Resolved
OILY WATER SEPERATOR SHUTDOWN WAS INOPERATIVE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Navigation
Issued 10 May 1995 Resolved
DEPTH RECORDER INOPERATIVE-TO BE REPAIRED PRIOR TO NEXT ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Engineering
Issued 10 May 1995 Resolved
OWILY WATER SEPERATOR NOT TO BE USED AND SHALL BE REPAIRED PROIR TO RE ENTRY TO U.S. WATERS.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Deck/Cargo
Issued 18 August 1993 Resolved
HYDRO TEST CARGO PIPING TO 1 1/2 X MAWP OF THE CARGO PUMPS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 18OCT93.
Condition: Unknown
Due 28 September 1993
Resolved 28 September 1993
Electrical
Issued 17 September 1992 Resolved
PROVE PROPER OPERATION OF NEWLY INSTALL "E" GEN PRIME MOVER I.E. ALL ALARMS& SHUTDOWNS AS PER 46 CFR 112.50 AND LOAD TESTING AS REQUIRED BY COGNIZANT OCMI. A MINIMUM OF 72HR NOTICE SHALL BE GIVEN TO OCMI AT FIRST U.S. PORT CALL AND THIS ITEM MUST BE CLEARED PRIOR TO DEPART SAME._x001C_
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Fire Fighting
Issued 6 August 1992 Resolved
PROVE PROPER OPERATION OF TIME DELAYS, PRESSURE SWITCHES AND ALARMS ON THE LP CO2 SYSTEM.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Fire Fighting
Issued 6 August 1992 Resolved
PROVIDE [name withheld] WITH A CURRENT FOAM ANALYSIS REPORT.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Navigation
Issued 6 August 1992 Resolved
PROVE PROPER OPERATION OF THE BACK UP RADAR UNIT.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Engineering
Issued 6 August 1992 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPRATION.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Engineering
Issued 6 August 1992 Resolved
PROVE PROPER OPERATION OF AIR RECEIVER AND DC HEATER RELIEF VALVES.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Deck/Cargo
Issued 6 August 1992 Resolved
PROVE PROPER OPERATION OF O2 METER INSTALLED IN CARGO CONTROL.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Electrical
Issued 6 August 1992 Resolved
PROVE PROPER OPERATION OF AUTO SWITCH FROM SSTG TO SSDG.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Fire Fighting
Issued 6 August 1992 Resolved
PROVE PROPER OPERATION OF THE TIME DELAYS, SIRENS, ALARMS PRESSURE SWITCHESAND BLOW DOWN OF THE HP CO2 SYSTEMS.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Lifesaving
Issued 10 April 1992 Resolved
PROVIDE VESSEL WITH CURRENTLY SERVICED INFLATABLE LIFERAFTS. LIFERAFTS NOW ON VESSEL MAY BE REMOVED FOR SERVICING. VESSEL MAY OPERATE IN GULF OF MEXICO LIGHTERING AREA OFF THE MISSISSIPPI RIVER, SOUTHWEST PASS, AND LOOP._x001C_
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Lifesaving
Issued 10 April 1992 Resolved
PROVIDE MSO MORGAN CITY WITH EVIDENCE OF SERVICING AND REINSTALLATION OF INFLATABLE LIFERAFTS. VESSEL NOT TO DEPART LOOP PRIOR TO REINSTALLATION OF CURRENT LIFERAFTS.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Unknown
Issued 21 October 1991 Resolved
PROVIDE FOR APPROVAL PLANS DETAILING MODIFICATIONS TO THE COW SYSTEM ONBOARD THE VESSEL. PLANS SHOULD BE PROVIDED TO THE COAST GUARD MARINE SAFETY CENTER IN WASHINGTON, D.C. THIS REQUIREMENT ORIGINALLY ISSUED BY HONMS; REISSUED AFTER MISTAKENLY CLEARED.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Unknown
Issued 22 July 1991 Resolved
PROVIDE FOR APPROVAL THE PLANS FOR THE LIQUID LEVEL GAUGING AND HIGH LEVEL ALARM SYSTEMS ON BOARD THE VESSEL. PLANS SHOULD BE SUBMITTED TO THE COAST GUARD MARINE SAFETY CENTER IN WASHINGTON D.C.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Lifesaving
Issued 22 July 1991 Resolved
REPLACE RING BUOYS AND WATER LIGHTS WITH U.S. COAST GUARD SOLAS 83_x001C_ APPROVED EQUIPMENT.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Construction/Loadline
Issued 22 July 1991 Resolved
REPLACE THE EXISTING CARGO MONITOR AND CONTROL SYSTEM OIL CONTENT METER WITH ONE APPROVED UNDER 46CFR162.050. THE VESSEL MAY NOT PUMP OILY CARGO TANK BALLAST OVERBOARD UNTIL THIS EQUIPMENT IS ON BOARD AND TESTED IN THE PRESENCE OF A U.S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
PROVIDE THE VESSEL WITH A SOLAS TRAINING MANUAL COMPLYING WITH CH III REGULATION 51 OF SOLAS AS REQUIRED BY CH III REGULATION 18 OF SOLAS 83.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
PROVIDE OPERATING INSTRUCTIONS FOR DAVIT, WINCH, AND LIFEBOAT CONTROLS, ANDLIFEBOAT MOTORS PER CH III SECTION 9 OF SOLAS 83.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Unknown
Issued 22 July 1991 Resolved
PROVIDE ON BOARD A BREATH TESTING DEVICE PER 46CFR4.06-20.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Unknown
Issued 22 July 1991 Resolved
PROVIDE FOR APPROVAL PLANS DETAILING MODIFICATIONS TO THE COW SYSTEM ONBOARD THE VESSEL. PLANS SHOULD BE PROVIDED TO THE COAST GUARD MARINE SAFETY CENTER IN WASHINGTON D.C.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Construction/Loadline
Issued 22 July 1991 Resolved
REPLACE THE EXISTING OIL/WATER SEPARATOR BILGE MONITOR WITH ONE APPROVED UNDER 46CFR162.050. NO BILGE SLOPS MAY BE PUMPED OVERBOARD UNTIL THIS DEVICE IS INSTALLED AND TESTED IN THE PRESENCE OF A U.S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Deck/Cargo
Issued 22 July 1991 Resolved
COMPLETE THE TANK VESSEL INSPECTION REQUIRED BY 33CFR140 TO PROVE THE ADEQUACY OF THE NEW CRUDE OIL WASHING SYSTEM. THIS INSPECTION MAY BE CONDUCTED BY ABS WITH THE RESULTS FORWARDED.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
UPDATE THE VESSEL'S CARGO/BALLAST OPERATIONS MANUAL PER 33CFR157.23. INFORMATION MUST BE INCLUDED ON NEW GAUGING SYSTEMS.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
UPDATE THE VESSEL'S CRUDE OIL WASHING OPERATIONS AND EQUIPMENT MANUAL APPROVED UNDER 33CFR157.116 WITH INFO REQUIRED PER 33CFR157.138.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
UPDATE THE VESSEL'S OIL TRANSFER PROCEDURES PER 33CFR155.740.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
UPDATE THE VESSEL'S IGS OPERATIONS MANUAL.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Unknown
Issued 22 July 1991 Resolved
CONDUCT A TEST OF THE SAFETY TRIPS ON THE NEWLY INSTALLED INCINERATOR IN THE PRESENCE OF A COAST GUARD INSPECTOR. UNTIL THIS IS DONE THE INCINERATOR MAY NOT BE USED TO BURN WASTE.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Lifesaving
Issued 22 July 1991 Resolved
INSTALL ONE CLASS A FLOAT FREE EPIRB ON THE BRIDGE, AND MOVE THE EPIRBS_x001C_ FOR THE LIFEBOATS TO THE VICINITY OF THE BOATS THEMSELVES. THE BRIDGE EPIRB MAY BE EITHER A 121.5/243 EPIRB OR A 406 SATELLITE EPIRB.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Lifesaving
Issued 22 July 1991 Resolved
INSTALL U.S. COAST GUARD SOLAS APPROVED LIFE JACKET LIGHTS ON ALL LIFE JACKETS.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991

Ownership record