Records from 2023 to 2026. Most recent: inspection, 20 April 2026.
Inspection history · 6
20 April 2026
Annual Inspection · Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8300966
15 July 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096523
27 May 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096498
22 August 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7964101
10 April 2023
Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7666202
7 February 2023
Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7654444
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2026
Resolved
A vessel not required to have a power driven fire pump
by § 181.300 must have at least three 9.5 liter (2.5
gallon) buckets, with an attached lanyard satisfactory
to the cognizant OCMI, placed so as to be easily
available during an emergency. The words “FIRE BUCKET”
must be stenciled in a contrasting color on each bucket.
MI observed 03 undersized fire buckets that were only
5.5 qt in size.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator replaced 03 undersized fire buckets and sent photograph of new 2.5 gallon buckets. See documents for photo.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2026
Resolved
A vessel on a lakes, bays, and sounds route must carry:
Three hand red flare distress signals approved in
accordance with § 160.021 and three hand orange smoke
distress signals approved in accordance with § 160.037.
MI observed all flares on board the vessel were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator replaced expired flares with 06 new red hand flares.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2026
Resolved
Electrical equipment on a vessel must be installed and
maintained to: Protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. MI observed multiple non-permanent
power strips, adapters, and an extension cord connected
to a single receptacle, which presents a potential fire
hazard due to overloading and not suitable for continued
marine service.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 8 May 2026
Resolution: Vessel removed extension cord and additional power strips.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2026
Resolved
Portable fire extinguishers must be located so that they
are clearly visible and readily accessible from the
space being protected. The installation and location
must be to the satisfaction of the Officer in Charge,
Marine Inspection. MI observed all portable fire
extinguishers on board were not secured with a bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 24 April 2026
Resolution: O/O secured all fire extinguishers with new brackets and provided photos. See documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2026
Resolved
A vessel must carry a first-aid kit that meets the
requirements in 46 CFR 199.175(b)(10). A first-aid kit
must be easily visible and readily available to the
crew. MI observed multiple items were expired in the
first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator purchased a new first aid kit to replace the expired one.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2026
Resolved
Unless other means are provided to ensure that a
potential waste receptacle fire would be limited to the
receptacle, waste receptacles must be constructed of
noncombustible materials with no openings in the sides
or bottom. MI observed all waste receptacles on board
the vessel were plastic and not of a noncombustible
material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator purchased a non-combustable waste receptacle. See documents for photo.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 15 July 2025
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. MI observed vessel operator did not have a FCC radio operator license. Vessel is required to have one licensed master with another person who holds a FCC radio operator license on board if licensed master does not have a valid FCC radio operator license.
47 CFR 80.155
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2025
Resolved 23 July 2025
Resolution: MI received photo from vessel operator of FCC license.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed that portable extinguishers did not have brackets on them.
46 CFR 181.520
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 23 July 2025
Resolution: MI received photo from vessel operator of installed brackets on the portable fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2025
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed vessel only had one fire bucket on-board.
46 CFR 181.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 28 July 2025
Resolution: MI received pictures from vessel operator of the three 2.5 gallon buckets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 April 2023
Resolved
Except as provided in 173.17, no person may use a vessel to which this part applies unless: it has a number issued on a certificate of number by the issuing authority in the state of principle operation and the number is displayed as described in 173.27. Vessel waiting on number from state, application has been submitted.
33 CFR 173.15
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2023
Resolved 10 July 2023
Resolution: Operator provided proof of California registration and official CF#.