MAURY USCG vessel records
← All vessels

THE DUCHESS PUB

THE DUCHESS PUB is a 2023 passenger vessel (inspected). The Coast Guard has recorded 6 inspections since 2023, most recently in April 2026, along with 10 deficiencies.

Records from 2023 to 2026. Most recent: inspection, 20 April 2026.

Built
2023
Last inspected
20 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 April 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN9393
1769858
Flag
UNITED STATES
Maury page id
psix-1769858

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

20 April 2026 Annual Inspection · Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8300966
15 July 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096523
27 May 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096498
22 August 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7964101
10 April 2023 Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7666202
7 February 2023 Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7654444

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2026 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2.5 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed 03 undersized fire buckets that were only 5.5 qt in size.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator replaced 03 undersized fire buckets and sent photograph of new 2.5 gallon buckets. See documents for photo.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2026 Resolved
A vessel on a lakes, bays, and sounds route must carry: Three hand red flare distress signals approved in accordance with § 160.021 and three hand orange smoke distress signals approved in accordance with § 160.037. MI observed all flares on board the vessel were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator replaced expired flares with 06 new red hand flares.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed multiple non-permanent power strips, adapters, and an extension cord connected to a single receptacle, which presents a potential fire hazard due to overloading and not suitable for continued marine service.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 8 May 2026
Resolution: Vessel removed extension cord and additional power strips.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2026 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed all portable fire extinguishers on board were not secured with a bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 24 April 2026
Resolution: O/O secured all fire extinguishers with new brackets and provided photos. See documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2026 Resolved
A vessel must carry a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10). A first-aid kit must be easily visible and readily available to the crew. MI observed multiple items were expired in the first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator purchased a new first aid kit to replace the expired one.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2026 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. MI observed all waste receptacles on board the vessel were plastic and not of a noncombustible material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 20 April 2026
Resolution: Operator purchased a non-combustable waste receptacle. See documents for photo.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 15 July 2025 Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. MI observed vessel operator did not have a FCC radio operator license. Vessel is required to have one licensed master with another person who holds a FCC radio operator license on board if licensed master does not have a valid FCC radio operator license. 47 CFR 80.155
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2025
Resolved 23 July 2025
Resolution: MI received photo from vessel operator of FCC license.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2025 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed that portable extinguishers did not have brackets on them. 46 CFR 181.520
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 23 July 2025
Resolution: MI received photo from vessel operator of installed brackets on the portable fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2025 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed vessel only had one fire bucket on-board. 46 CFR 181.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 28 July 2025
Resolution: MI received pictures from vessel operator of the three 2.5 gallon buckets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 April 2023 Resolved
Except as provided in 173.17, no person may use a vessel to which this part applies unless: it has a number issued on a certificate of number by the issuing authority in the state of principle operation and the number is displayed as described in 173.27. Vessel waiting on number from state, application has been submitted. 33 CFR 173.15
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2023
Resolved 10 July 2023
Resolution: Operator provided proof of California registration and official CF#.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.