USACE LEITNER

USACE LEITNER is a towing vessel. The Coast Guard has recorded 3 inspections since 2023, most recently in April 2026, along with 7 deficiencies.

Records from 2023 to 2026. Most recent: inspection, 27 April 2026.

Built
Not recorded
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1770668
Flag
UNITED STATES
Maury page id
psix-1770668

Inspections, by type

Years with a record 3 calendar years (2023–2026)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 3

27 April 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8358688
6 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8131063
29 March 2023 Examination of Repairs · Initial Certification · Deficiency Check · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7659195

Deficiency record · 7

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 February 2024 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along the escape routes and sufficiently visible to enable egress with no power. E-lighting is in the correct locations but do not illuminate automatically.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2024
Resolution: Rectified, see description in narrative.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 February 2024 Resolved
Fuel shut off (d) The valve must be operable from a safe space where the valve is installed (e) Each remote valve control must be marked in clearly legible letters, at least 1” high, indicating the purpose of the valve and the way to operate it. No fuel shut off located outside the emergency space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2024
Resolution: Installed, tested and functioning, labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2024 Resolved
Piping and machinery components that exceed 428 F degrees, including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Provide lagging as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2024
Resolution: Lagging installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 February 2024 Resolved
The portable fire pump must be self-priming and power driven, with: (1) A minimum capacity of at least 80 gpm at a discharge gauge pressure of not less then 60 PSI, measured at the pump discharge. Portable pump did not have a gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2024
Resolution: Gauge installed and pump discharging at 100 PSI.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 7 February 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2024
Resolution: EPIRB purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 February 2024 Resolved
Each towing vessel must carry at least one appropriately-sized life jackets approved under the appropriate approval series, for each person onboard. Vessel's COI allows for 06 total persons onboard but was found to have only 04 lifejackets onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2024
Resolution: 06 PFDs onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 February 2024 Resolved
Every towing equipped with an inflatable survival craft must have, in conspicuous places near each inflatable survival craft, approved placards or other posted instructions for launching and inflating survival craft. Placard/instructions were missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 February 2024
Resolution: Instruction placard provided.