MAUD

MAUD is a 1979 towing vessel. The Coast Guard has recorded 23 inspections since 1999, most recently in July 2022, along with 21 deficiencies, 1 operational control and 1 casualty investigation in 2005.

Records from 1999 to 2022. Most recent: inspection, 11 July 2022.

Built
1979
Last inspected
11 July 2022
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 11 July 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1999–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WXX 7908
177216
Flag
UNITED STATES
Maury page id
psix-177216

Documentation record

Registered dimensions (L × B × D)41.1 ft × 18.6 ft × 6.1 ft
Registered tonnagegross 51 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBARBOUR METAL BOAT WORKS · ST. LOUIS, MO, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLACON, IL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Net Ton
51 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

11 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7503734
6 October 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7328043
17 August 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7290304
25 June 2020 Initial Certification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6986595
6 April 2013 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4563781
20 February 2013 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4536506
20 February 2013 Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4536522
20 September 2012 DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4446155
17 February 2010 MARPOL · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3682264
10 December 2008 Administration · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3378906
1 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3371860
25 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2940924
23 April 2007 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2917115
15 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2585552
9 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2531494
21 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2500039
14 September 2005 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2492359
6 July 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2452696
17 April 2003 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1775451
24 April 2002 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1609133
21 March 2002 Uninspected Other
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1599726
4 October 2000 Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1403236
10 February 1999 Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 795995

Deficiency record · 21

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 August 2021 Resolved
First aid kit contents expired. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 October 2021
Resolution: Expired items were replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 August 2021 Resolved
Repair all various cracks located on push knees and upper deck hand rails marked by Marine Inspector
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2021
Resolution: Inspector clear with objective evidence from vessel owner
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 April 2007 Resolved
Provide proof fuel piping between Port and Starboard fuel tanks and the remote fuel shutoff valve is heavy duty piping (schedule 80) per 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Remote fuel shutoffs moved to new location at tanks.
Fire Fighting › Fire Pumps › Pressure
Issued 23 April 2007 Resolved
Portable fire pump not working (unable to start) per 46 CFR 27.301
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Fire Pump now working.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 23 April 2007 Resolved
Certified fire detection system not working per 46 CFR 27.203
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Fire Detection System now working.
Documentation › Markings/Placards › Warning Signs
Issued 23 April 2007 Resolved
General alarm placard (warning sign) not by alarm system per 46 CFR 27.201(a)(3)
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: General Alarm Placard now in place.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 April 2007 Resolved
Remote Fuel Oil Shutoff instructions required at pull line per 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Remote Fuel Shutoff now labeled with operating instructions.
Lifesaving › Lifebuoys › Serviceable
Issued 23 April 2007 Resolved
Lines for lifebuoys need replacing (worn and frayed) per 46 CFR 25.25-5(d)
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Lines have been replaced.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 April 2007 Resolved
Need current publication of Coast Guard Light List per 33 CFR 164.72(b)(2)
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Current Coast Guard light list now on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 April 2007 Resolved
Lower amber towing light not working per 33 USC 2024(i)
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Amber Towing Light now working.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 9 November 2005 Resolved
Provide proof that fire detection system is certified by a professional engineer or a classification society as required under 46 CFR 27.203 See 46 CFR 27.203 (g) for requirements
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 3 February 2006
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 9 November 2005 Resolved
Fire detection system power panel needs battery backups as required under 46 CFR 27.210 (e)
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 3 February 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 13 September 2005 Resolved
Fire Pump as required under 46 CFR 27.301 not on board.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2005
Resolution: Fire Pump installed on vessel
Communications › Alarms/Indicators › General Alarm
Issued 13 September 2005 Resolved
General Alarm and flashing red light not on board as required under 46 CFR 27.201
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2005
Resolution: General Alarm and flashing red light installed as required undr 46 CFR 27.201
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 September 2005 Resolved
Magnetic compass on board not illuminated as required under 33 CFR 164.72 (a)(4)
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 8 November 2005
Resolution: Magnetic compass install and illuminated as required under 33 CFR 164.72 (a0(4)
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 13 September 2005 Resolved
Local notice to mariners not on board as required under 33 CFR 164.72 (b) (2)
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 8 November 2005
Resolution: Company will get Local notice to mariners from neighbooring company and have onboard as required under 33 CFR 164.72 (b)(2)
Personnel › Training › Fire Fighting Basic
Issued 13 September 2005 Resolved
No monthly records or evidence of fire fighting training for crew being conducted as required under 46 CFR 27.209
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 8 November 2005
Resolution: Company has training tapes and starting a training program and will log monthly drills and training as required under 46 CFR 27.209
Electrical › Electrical Distribution System (service)
Issued 1 April 2002 Resolved
NAVIGATION LIGHTS NOT WORKING DUE TO ELECTRICAL SYSTEM FAILURE 33 USC 202 (a) LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2002
Resolution: NAVIGATION LIGHTS NOW WORKING
Fire Fighting › Remote Fuel Shutoff
Issued 1 April 2002 Resolved
NO REMOTE FUEL OIL SHUT OFF INSTALLED 46 CFR 27.230
Due 10 April 2002
Resolved 10 April 2002
Resolution: REMOTE FUEL OIL SHUTOFF NOW INSTALLED
Fire Fighting
Issued 4 October 2000 Resolved
FIRE EXTINGUISHERS INSPECTION DATE LAPSED.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Lifesaving
Issued 4 October 2000 Resolved
RING BOUYS MISSING RETROREFLECTIVE MATERIAL.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000

Casualty record · 1

6 July 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2452696
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.