Records from 2001 to 2011. Most recent: inspection, 1 September 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
1 September 2011
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4138240
6 March 2009
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3428073
18 September 2008
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3327610
30 July 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3283891
10 June 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3233627
25 March 2008
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3170998
18 April 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2910249
11 April 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2906106
23 January 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2860584
10 November 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2532369
13 October 2005
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2512697
22 January 2004
Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1990257
13 January 2003
Annual Inspection · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1729355
11 January 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1481129
11 January 2001
Hull Examination · COI Inspection · Plan Review "T" Boat
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1463608
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 September 2011
Resolved
Make repairs to the Emergency lighting in forward cabin
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 14 September 2011
Resolution: New Emergency lighting installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 September 2011
Resolved
Have the engine room system serviced prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 14 September 2011
Resolution: Sighted service report.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 September 2011
Resolved
Make repairs to the bilge alarms in the engine room and forward saloon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 14 September 2011
Resolution: New alarm sytem installed
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 September 2011
Resolved
Get a training \ drill log.
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 14 September 2011
Resolution: Sighted new logs.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 September 2011
Resolved
Review and revise Emergency instruction for the use of the rescue platform.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 14 September 2011
Resolution: Sighted revised instruction.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 1 September 2011
Resolved
make a Devistion card for the Magnetic compass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 14 September 2011
Resolution: New Magnetic compass installed
Stability › Severe Wind/Roll › General
Issued 18 September 2008
Resolved
Suspended COI. Prior to re issue complete credit drydock and internal structural exams and Inspection for Certification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2009
Resolution: Attended vessel cleared deficiency.
Construction/Loadline › Hull › Bottom Plating
Issued 25 March 2008
Resolved
Replace the bottom plate and framing in the steering compartment as marked. Approx. size 8' x 7'.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2008
Resolved 24 April 2008
Resolution: Bottom plate and framing 2 sections of 4'' x 8'' x 3/16 and 20 '' of angle iron. Repairs were air tested satisfactory.
Stability › Unintentional Flooding › General
Issued 25 March 2008
Resolved
Insert the main deck below the hand rails in way of the holed areas.
Due 26 April 2008
Resolved 24 April 2008
Resolution: Main deck repairs were counducted and tested sat.
Engineering › Fuel Oil Service System › Hose
Issued 25 March 2008
Resolved
Replace all flexable fuel lines over 30 inches in the machinery space with fixed piping.
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 24 April 2008
Resolution: Flexable fuel lines replaced with copper tubeing .
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 25 March 2008
Resolved
Replace the rotted wooden deck beam in the main forward cabin.
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 24 April 2008
Resolution: Rotted wood deck beam in the main forward cabin replaced satisfactory.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 25 March 2008
Resolved
Replace the rotted wood on the starboard side of the main forward cabin.
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 24 April 2008
Resolution: Starboard side of main forward cabin rotted wood replaced.
Stability › Watertight Integrity › General
Issued 25 March 2008
Resolved
Vessel required to seal repairs counducted to stbd deck house for intrustion of water.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 10 June 2008
Resolution: Repairs made.
Engineering › Fuel Oil Service System › Piping
Issued 25 March 2008
Resolved
Vessel required to replace fuel line from Hydraulic service to fuel service.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 29 July 2008
Resolution: Item repaired.
Engineering › Bilge Water Management System › Not Operational
Issued 25 March 2008
Resolved
Engine room Bilge alarm not alarming.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 29 July 2008
Resolution: Item repaired.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 10 January 2007
Resolved
Place and maintain waste management plan on board vessel.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Navigation › Piloting/Steering › Marine Charts
Issued 10 January 2007
Resolved
Update navigation charts.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Lifesaving › Hand Flares › Not on Board
Issued 10 January 2007
Resolved
Place two orange smoke flares onboard vessel to make a total of three.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Construction/Loadline › Structures › Deck Plating
Issued 10 January 2007
Resolved
Permanently repair 3" x 1" hole in stbd bow weather deck at rail stantion.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 10 January 2007
Resolved
Afix hull markings to hull - vessel name, hailing port.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 January 2007
Resolved
Replace expired items in first aid kit.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 January 2007
Resolved
Replace/recharge fire extinguisher in galley.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 January 2007
Resolved
Replace all residental grade wire nuts with marine grade connectors.
Due 25 April 2007
Resolved 18 April 2007
Resolution: Item corrected.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 January 2007
Resolved
Close open electrical box near fixed CO2 bottle.
Due 25 April 2007
Resolved 18 April 2007
Resolution: Item corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 January 2007
Resolved
Permanently repair frayed light fixture wiring in engine room.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 January 2007
Resolved
Place additional portable light onboard to make a total of two.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Fire Fighting › Fire Hoses › Condition
Issued 10 January 2007
Resolved
Replace fire hose.
Due 10 February 2007
Resolved 11 April 2007
Resolution: Item corrected.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 October 2005
Resolved
REPLACE BATTERY AND PROVE PROPER OPERATION OF THE EMERGENCY LIGHTING SYSTEM.
Due 13 November 2005
Resolved 10 November 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 October 2005
Resolved
Remove oil and oily water from the bilge.
Due 13 November 2005
Resolved 10 November 2005
Construction/Loadline › Hull
Issued 13 January 2003
Resolved
Renew coating on bottom plating. Upon new application of coating allow recommended time for coating to dry prior to placing vessel in service. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 13 February 2003
Resolution: Bottom coating renewed.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2003
Resolved
Make starboard center void ready for inspection, remove rust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 13 February 2003
Resolution: Area was primed and painted and ready for inspection.
Engineering
Issued 13 January 2003
Resolved
Make engine room ready for inspection, remove oil/debris in bilge and pull all through hull fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 13 February 2003
Resolution: Bilge was cleaned and through hull fittings were pulled for inspection.
Electrical › Electric Supply System (service) › Cable
Issued 13 January 2003
Resolved
Remove all household wires and replace w/ approved marine grade wire.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 13 February 2003
Resolution: Wires replaced w/ 16 AWG
Documentation › Certificates/Documents › Stability Letter
Issued 11 January 2002
Resolved
Post stability letter under glass so that both pages are showing.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 January 2002
Resolution: Stability letter posted.
Fire Fighting › Fire Hoses › Material
Issued 11 January 2002
Resolved
Replace fire nozzle with approved nozzle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 January 2002
Resolution: Nozzle replaced