Records from 2024 to 2026. Most recent: inspection, 17 January 2026.
Documentation record
Registered dimensions (L × B × D)61.6 ft × 16.5 ft × 7.2 ft
Registered tonnagegross 36 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROTHERS ENT. INC. · LOREAUVILLE, LA, UNITED STATES · built 2024
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portMAALAEA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel reported loss of propulsion during passenger operation. Provide technical report, make operational and as designed to the satisfaction of attending marine inspector. Sea trials required. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2026
Resolution: Loose wiring reconnected. Cause bad linkage to throttle and determined to be the cause of eng. failure. No further requirement
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 July 2025
Resolved
The float-free link required by § 180.130(a)(1) must be: Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. The float-free link installed on this vessel has a breaking strength for 21 persons, which exceeds the required breaking strength for 15-man life floats, installed on vessel as per the COI. Replace float free links with correct size link or combine lines to 1 link. 46 CFR 180.137(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 22 August 2025
Resolution: New weak links installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 9 July 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shut off valves require direction of closure markings. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 22 August 2025
Resolution: Fuel shut off valve markings installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. All Marlin Type 1 life jackets installed on vessel (Model 320RT for Adults and Model 321RT for Child size) have a malfunctioning spring-loaded tab on the snap hook of the safety strap. The spring-loaded tabs fail to spring back,(return to closed position) after depressing to secure snap hook in place. No later than 18 July 2025, inform [name withheld] of the corrective action plan to replace all affected life jackets installed on board with fully functioning Type 1 Adult and Child size life jackets. 46 CFR 176.808(b)
Action required: 705 - Other - as specified
Due 9 August 2025
Resolved 22 August 2025
Resolution: Vessel owner replaced all affected life jackets and installed on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2025
Resolved 22 August 2025
Resolution: Reduced manning procedure renewed and put on board vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2025
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 46 CFR 181.500(a) and other provisions of this section. Vessels portable fire extinguishers did not meet class type requirements as per vessels COI. Vessel owner installed new serviceable fire extinguishers during inspection. Deficiency cleared. No further requirements. 46 CFR 181.500(a)
Action required: 10 - Deficiency Rectified
Resolved 9 July 2025
Resolution: New extinguishers installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 June 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Vessel does not have a means of manually activating the pre-engineered fixed gas fire extinguishing system.
46CFR181.420(a)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2024
Resolution: Received video from operator of properly functioning fireboy.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 June 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Engine room air intakes for port and starboard engine rooms do not have a means of closure.
46 CFR 182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2024
Resolution: Received photo and video from operator of properly installed and functioning vent closures.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 June 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The T- handles for the shutoff valves were not in place.
46 CFR 185.604(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2024
Resolution: Received image from operator of properly installed t-handles.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing actions to be taken in the even of fire, heavy weather, or man overboard. Vessel did not have emergency instructions.
46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2024
Resolution: Vessel operator provided photograph of emergency instructions posted.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 17 June 2024
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan is on the ship and that each person handling garbage follows the plan. Vessel did not have a garbage management plan.
33 CFR 151.57
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2024
Resolution: Vessel operator provided photograph of garbage managmenet plan.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 June 2024
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and number on each life float. Life floats not marked with allowable capacity of persons.
46CFR185.604(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2024
Resolution: Received photo of properly labeled life float.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2024
Resolved
Equipment and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Fuses on both port and starboard engines are not mounted.
46CFR176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2024
Resolution: Received photos of mounted fuses