This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2023
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9478494
1774747
Flag
MARSHALL ISLANDS
Maury page id
psix-1774747

Documentation record

Tonnage as PSIX records it39906 - Convention (Subpart B), Gross Ton
24504 - Convention (Subpart B), Net Ton
50595 - Dead Weight, Metric Ton
67300 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

2 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

5 June 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7703648
31 May 2023 Deficiency Check · PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7701975

Deficiency record · 8

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 31 May 2023 Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The company should ensure; appropriate corrective action is taken. PSCO observed, during an expanded exam the following: Failure of the company and ship to properly manage failing E/R equipment, to include, M/E cooling water system, M/E F/O lines, hydraulic pump cooling system, and boiler. An external ISM audit is required prior to release from the detention. 74SOLAS(20) IX/3.1 ISM Code 10
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 June 2023
Resolution: Received results of ISM audit from Class.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 May 2023 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed excessive leakage of F/O in several locations on the M/E fuel return lines and oil soaked lagging, as well as diesel fuel spraying from the pressure gauge on the diesel fuel line. 74SOLAS(20)IX/3.1 74 SOLAS (09 cons.) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 June 2023
Resolution: Received Class report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 May 2023 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed excessive leakage of jacket cooling water from cooling water line going to M/E cylinder #2. 74SOLAS(04)II-1/26.1 74 SOLAS (04 Cons.) II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs and performed CG def check on 02JUN23.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. PSCO observed inoperable cooling water system for the main L/O hydraulic pump. Multiple portable fans were found near pump for cooling. Hydraulic valve control panel showed failure of pump. 74SOLAS(04) II-2/4.2.3.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs, and performed CG def check on 02JUN23.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 31 May 2023 Resolved
Every steam pupe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed an excessive steam leak on the boiler steam pipe. 74SOLAS(04) II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Received Class report attesting to temp. repair until next dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the adminstration. PSCO observed several temporary repairs to the feed water supply line going to the boiler. 74SOLAS(20) I-11 (b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs, and performed CG def check on 02JUN23.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
Hydraulic power-operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir, where the main steering gear is required to be power-operated. PSCO observed hydraulic fluid of fixed storage tank below minimum operating level. 74SOLAS (04) II-1/29.12.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs, and performed CG def check on 02JUN23.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 May 2023 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background, they shall also be permanently marked on the sides of the ships to the satisfaction of the Administration. PSCO observed load line not painted of contrasting color to hull. ICLL (88 Prot) Reg 8
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 June 2023
Resolution: Received Class report attesting to repainting.

Ownership record