15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 31 May 2023
Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The company should ensure; appropriate corrective action is taken. PSCO observed, during an expanded exam the following: Failure of the company and ship to properly manage failing E/R equipment, to include, M/E cooling water system, M/E F/O lines, hydraulic pump cooling system, and boiler. An external ISM audit is required prior to release from the detention.
74SOLAS(20) IX/3.1 ISM Code 10
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 June 2023
Resolution: Received results of ISM audit from Class.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 May 2023
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed excessive leakage of F/O in several locations on the M/E fuel return lines and oil soaked lagging, as well as diesel fuel spraying from the pressure gauge on the diesel fuel line.
74SOLAS(20)IX/3.1
74 SOLAS (09 cons.) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 June 2023
Resolution: Received Class report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 May 2023
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed excessive leakage of jacket cooling water from cooling water line going to M/E cylinder #2.
74SOLAS(04)II-1/26.1
74 SOLAS (04 Cons.) II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs and performed CG def check on 02JUN23.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. PSCO observed inoperable cooling water system for the main L/O hydraulic pump. Multiple portable fans were found near pump for cooling. Hydraulic valve control panel showed failure of pump.
74SOLAS(04) II-2/4.2.3.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs, and performed CG def check on 02JUN23.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 31 May 2023
Resolved
Every steam pupe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed an excessive steam leak on the boiler steam pipe.
74SOLAS(04) II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Received Class report attesting to temp. repair until next dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the adminstration. PSCO observed several temporary repairs to the feed water supply line going to the boiler.
74SOLAS(20) I-11 (b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs, and performed CG def check on 02JUN23.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023
Resolved
Hydraulic power-operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir, where the main steering gear is required to be power-operated. PSCO observed hydraulic fluid of fixed storage tank below minimum operating level.
74SOLAS (04) II-1/29.12.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Received Class report attesting to repairs, and performed CG def check on 02JUN23.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 May 2023
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background, they shall also be permanently marked on the sides of the ships to the satisfaction of the Administration. PSCO observed load line not painted of contrasting color to hull.
ICLL (88 Prot) Reg 8
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 June 2023
Resolution: Received Class report attesting to repainting.