Records from 2023 to 2026. Most recent: inspection, 4 June 2026.
Inspection history · 10
4 June 2026
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8390923
3 June 2026
PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8385312
17 February 2026
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8311672
5 January 2026
Administrative Inspection · PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8290123
23 July 2025
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8194322
2 July 2025
PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8172785
16 January 2025
PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8062885
9 July 2024
PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7952831
3 December 2023
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7832870
1 June 2023
PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7699588
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed exposed wiring on a light beneath the shaft seal.
Cite: 74 SOLAS 2009 II-1/45.1.3
Code: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2026
Resolution: Exposed wires were wrapped in electrical tape.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 June 2026
Resolved
Surfaces with temperatures above 220 degrees Celsius which may be impinged as a result of a fuel system failure shall be properly insulated. PSCO observed missing lagging on hot oil pipe near shaft seal.
Cite: 74 SOLAS 2009 II-2/4.2.2.6.1
Code: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2026
Resolution: New lagging was installed around the pipe where it had been missing.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 June 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a leak from HFO NO. 2 tank level indicator whihc caused excessive pooling.
Cite: 74 SOLAS 2009 II-2/4.1.1
Code: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2026
Resolution: Leak was identified and parts replaced. Oil on deck was wiped up.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 June 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed excessive oil soaked lagging in various locations throughout the engine room.
Cite: 74 SOLAS 2009 I/11(a)
Code: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2026
Resolution: Engineering crew replaced oil soaked lagging with new lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 June 2026
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the code. All life-saving appliances prescribed in this part shall be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the organization. PSCO observed that the retro reflective tape on the top of the freefall lifeboat was no longer reflective.
Cite: 74 SOLAS 2024 III/34
LSA Code CH 1, Section 1.2.7
Code: 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 4 June 2026
Resolution: Retro reflective tape on top of the freefall lifeboat was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 January 2026
Resolved
EFFICENT GUARD RAILS OR BULWARKS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECK. PSCO OBSERVED A GUARD RAIL ON THE PORT SIDE OF THE VESSEL NEAR CARGO BAY 25 THAT HAD TWO POINTS OF FAILURE, THE TOP RAIL WAS DISCONNECTED FROM TWO STANCHIONS. THE TOP GUARD RAIL ON THE STARBOARD SIDE OF THE VESSEL NEAR CARGO BAY 15 HAS ONE POINT OF FAILURE, DISCONNECTED FROM THE BULWARK.
LOAD LINE 66 I/25.2
16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 26 January 2026
Resolution: Vessel submitted photographs showing repairs made to the railings.
01 - Certificates & Documentation › 011 - Ships Certificates › International Anti-fouling-System Certificate
Issued 2 July 2025
Resolved
Cite: AFS Convention IV/1.4.c. Action Taken: 40bc
When the Administration, a nominated surveyor, or a recognized organization determines that the ship's anti-fouling system does not conform either to the particulars of a certificate required under regulation 2 or 3, or to the requirements of this convention, such Administration, surveyor or organization shall immediately ensure that corrective action is taken to bring the ship into compliance. PSCO observed growth on the bulbous bow.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2025
Resolution: Vessel removed growth and was able to reapply paint to rusted areas where growth occured. Conducted examiton of hull, all was found to be sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 January 2025
Resolved
With a periodically unattended machinery space or when only one person is required on watch, there shall be immediate water delivery from the fire main system at a suitable pressure. PSCO observed inadequate water pressure for approximately 30 minutes after the activation of the pump.
SOLAS20 II-2/10.2.1.2.2.2
10c
Action required: 10 - Deficiency Rectified
Due 16 January 2025
Resolved 16 January 2025
Resolution: PSCO oberseved the fire main system with adequate pressure prior to departure from the vessel.