MAURY USCG vessel records
← All vessels

SOUTHERN XANTIS

SOUTHERN XANTIS is a 2020 tank ship. The Coast Guard has recorded 2 inspections in 2024, along with 2 deficiencies and 1 operational control.

Records in 2024. Most recent: operational control imposed, 19 August 2024.

Built
2020
Last inspected
19 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 August 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9883493
1776135
Flag
LIBERIA
Maury page id
psix-1776135

Documentation record

Tonnage as PSIX records it8108 - Convention (Subpart B), Net Ton
14938 - Convention (Subpart B), Gross Ton
25887 - Dead Weight, Ton
33166 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

19 August 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7984304
15 August 2024 PSC B · COC-CHEM & TVE Annual · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7981708

Deficiency record · 2

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 18 August 2024 Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. PSCO attended the vessel to determine the condition of the vessel's cargo tanks (2P, 4P, 10P, 11P, 12P, 7S, 8S, 10S, 11S) that were discharging gasoline and octane plus. PSCO requested [name withheld] and crew to measure the O2% of the above referenced tanks. at 1850 local on 18AUG2024, seven of the tanks were greater than 7% O2 with 4P reading 20.9%, 2P reading 19.6%, and 7S reading 16.3%. Cargo operations were stopped and will not be permitted to resume discharge remaining cargo until cargo tanks are in a safe conditions. PSCO has requested an internal ISM Audit. 74 SOLAS IX/3.1, ISM Code 9.1, 17 ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2024
Resolution: Superintendent conducted Internal ISM Audit, noted 2 n/c and 7 DEFs. Auditor confirmed Nitrogen Generator in good working order and provided training. Satisfactory for additional ISM verification.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 18 August 2024 Resolved
The system shall be capable of inerting empty cargo tanks and maintaining the atmosphere in any part of the tank with an oxygen content not exceeding 8% by volume. PSCO observed six cargo tanks that had already discharged gasoline ashore with tank atmosphere reading greater than 8% O2 content. There were four tanks with O2 % above 15.0% O2. 74 SOLAS (20) II-2/5.5.1.1, FSS Code 2.2.1.2.1, 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2024
Resolution: Company revised ship/shore agreement, verified N2 generator in good working order, and condition of cargo tanks.

Ownership record