Records from 2023 to 2024. Most recent: inspection, 18 November 2024.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 September 2024
Resolved
In a ship where oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed excessive amount of fuel oil on auxiliary generator piping, HFO pump near ballast water pumps, and main engine. 74SOLAS(20)II-2 4.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2024
Resolved 19 September 2024
Resolution: Accumulated leaking fuel oil found around auxiliary generator, HFO pumps near ballast water pumps and main engine has been thoroughly cleaned and no active leakage was found. M/E No.8 cylinder fuel injector hose with broken shielding was replaced by OEM
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 September 2024
Resolved
Surfaces with temperature above 220C which may be impinged as a result of a fuel system failure shall be properly insulated. PSCO observed oil soaked lagging on the auxiliary generator piping, HFO pumps near ballast water pumps, and main engine. 74SOLAS(20)II-2 4.2.2.6.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2024
Resolved 19 September 2024
Resolution: Soaked lagging on the auxiliary generator piping, HFO pumps near ballast water pumps and main
engine has been removed, replaced and visually examined satisfactory on completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2024
Resolved
all electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed cylinder control system cabinet No.1. is left open and unable to be closed. 74SOLAS(20)II-1 45.1.3
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 October 2024
Resolved 19 September 2024
Resolution: Broken locks on cylinder control system cabinet No.1 have been renewed. Proper open/close operation verified.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 September 2024
Resolved
The machinery, boiler and other pressure vessels shall be protected as to reduce to a minimum any danger to persons on board, due regard being paid to the moving parts. PSCO observed detached doors on tha air compressor, exposing dangerous moving parts. 74SOLAS(20)II-1 26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2024
Resolved 16 September 2024