Records from 2016 to 2017. Most recent: operational control imposed, 19 November 2017.
Inspection history · 5
19 November 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6309625
19 October 2017
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6291125
10 October 2017
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6284636
10 May 2017
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6149215
15 October 2016
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6015965
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 10 October 2017
Resolved
CODE:1899 CITE:74SOLAS2001II-2/62.1 ACTION:40AC
THE INERT GAS SYSTEM REFERRED TO IN REGULATION 60 SHALL BE DESIGNED, CONSTRUCTED AND TESTEDE TO THE SATISFACTION OF THE ADMINISTRATION. INERT GAS SYSTEM PIPING WAS DISCOVERED TO HAVE PINHOLE LEAKS AND SOFT PATCHES ON SCRUBBER TOWER.
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 19 October 2017
Resolution: All the leaked two(2) pinholes area were extracted and then replaced with the plate of appropriate size, so that found in order.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 10 October 2017
Resolved
CODE:1899 CITE:74SOLAS(2014)1/11A ACTION:40AC
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE #3 CARGO PUMP MECHANICAL SEAL WAS DISCOVERED TO HAVE A LEAK.
Action required: 705 - Other - as specified
Due 14 October 2017
Resolved 19 October 2017
Resolution: The subject mechanical seal was replaced with new one and no leak was found, so that overall condition found in order.
Deck/Cargo › Ballast › Vents
Issued 10 October 2017
Resolved
CODE:1899 CITE:74SOLAS(2014)1/11A ACTION:40AC
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE FLAME SCREENS ON THE BALLAST WATER TANK VENTS ARE OF INADEQUATE SIZE.
Action required: 705 - Other - as specified
Due 14 October 2017
Resolved 19 October 2017
Resolution: The nineteen(19) flame screens were replaced with new ones of appropriate size, so that found in order.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 10 October 2017
Resolved
CODE:1899 CITE:74SOLAS(2014)1/11A ACTION:40AC
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE MSD WAS DISCOVERED TO HAVE PINHOLE LEAKS THROUGHOUT THE SYSTEM.
Action required: 705 - Other - as specified
Due 14 October 2017
Resolved 19 October 2017
Resolution: All the leaked four(4) pinholes area were extracted and then replaced with the plate of appropriate size, so that found in order.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 15 October 2016
Resolved
Provisions shall be made to guard against liquid rising in the venting system. The pressure vacum relief valves are set higher than the vessels P/V breaker. 74 SOLAS (14 CONS) II-2/11.6.3.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2016
Resolution: Recieved class survey attesting to the rectification of the deficiency.