MAURY USCG vessel records
← All vessels

HERRING

HERRING is a 1979 offshore supply vessel. The Coast Guard has recorded 12 inspections since 2016, most recently in February 2025, along with 10 deficiencies and 1 casualty investigation in 2011.

Records from 2011 to 2025. Most recent: inspection, 6 February 2025.

Built
1979
Last inspected
6 February 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 February 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7948421
WDH4834
177830
Flag
UNITED STATES
Maury page id
psix-177830

Documentation record

Registered dimensions (L × B × D)71.5 ft × 32.0 ft × 6.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

6 February 2025 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8038105
6 September 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7786261
19 July 2022 Drydock Exam · Periodic Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7510728
20 July 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7344875
20 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7178902
12 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7094321
9 November 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7092314
25 June 2020 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6991690
9 June 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6981047
20 June 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6720195
23 April 2019 Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6668620
27 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5921051

Deficiency record · 10

02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 6 September 2023 Resolved
The owner of a vessel shall ensure the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. During inspection of the engine room cracked welds were identified in the vicinity of the port and starboard generator exhaust trunks. A crack was identified on the starboard side where the exhaust trunk penetrated the main deck causing water ingress. Vessel is to repair all cracks and perform non destructive testing on welds in the water tight envelope prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2023
Resolution: Vessel repaired and tested areas called out. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2022 Resolved
The minimum capacity of the power fire pump must not be less than 60psi. Fire pump did not meet 60psi. Repair or replace fire pump to reach 60psi
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 27 July 2022
Resolution: Vessel rep provided photographic and video evidence of operable fire pump
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 July 2022 Resolved
All installed equipment must operate as designed. Fire detection panel on the bridge visual alarms were INOP. Repair to make operational.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 27 July 2022
Resolution: Vsl rep provided photographic and video evidence of working detection panel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2022 Resolved
During every drydock exam, the "leg to can" connection welds and the "can-pad" connection welds should be Non-destructively tested (NDT). Vessel did conduct NDT. Conduct NDT and provide report.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 28 July 2022
Resolution: Vsl rep provided report of NDT
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 July 2022 Resolved
The master or person in charge shall ensure that each crane is operated and maintained in accordance with API 2D. Crane was being serviced and was inoperable. Provide report of crane repair.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 28 July 2022
Resolution: Vsl rep provided crane report from third party.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the end of the fuel line to stop fuel flow when servicing accessories. The shut off valve at the tank shall be operable from outside the tank compartment. During inspection it was discovered that the emergency fuel shut valves for the port and starboard fuel tanks were altered and moved to a secondary valve, approximately 5' from the valve installed at the fuel tanks. Vessel shall alter placement of emergency fuel shut off valves to be located at the closest valve to the fuel tanks. Vessel surpassed previous 14 day deadline issued on 835V from 09JUN2020 inspection. Vessel did not communicate needs for any additional time needed for correction of issued deficiency above. Additionally, vessel representative stated they will not fix until they "decide to pull out for service". The decision to not correct the issued deficiency shows the company is not proactively managing the potential fire hazard identified onboard. Vessel may not move from its present location or operate any machinery onboard until corrected. Vessel shall schedule a deficiency check inspection when corrections are made to ensure on site verification is completed to the satisfaction of the attending marine inspector. 46CFR182.20-40(b)(3)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 July 2020
Resolution: Received video evidence of remote fuel shut off valves moved to proper location.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the end of the fuel line to stop fuel flow when servicing accessories. During inspection it was discovered that the emergency fuel shut valves for the port and starboard fuel tanks were altered and moved to a second valve, approximately 5' from the valve installed at the fuel tanks. Vessel shall alter placement of emergency fuel shut off valve to be located at the closest valve to the fuel tanks. 46CFR182.20-45(b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 25 June 2020
Resolution: Vessel did not meet timeline or request additional time. Vessel is not proactively managing deficiency. A new deficiency was issued with a code 60 to correct prior to movement. See activity 6981047.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2019 Resolved
The number and identification of the lifejackets must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Lifejackets that were located in accomodation spaces required labeling to identify thier location and number avaialble. 46 CFR 185(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2019
Resolved 24 June 2019
Resolution: Lifejacket locations and quantities were placarded.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 20 June 2019 Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Aft pilothouse window was damaged not allowing a clear view for navigation. 46 CFR 177.1030
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2019
Resolved 24 June 2019
Resolution: Pilothouse window was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 20 June 2019 Resolved
Stove sea rails require suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Newly installed stove did not contain sea rails. 46 CFR 184.220(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2019
Resolved 7 July 2019
Resolution: Sea rails were provided for new stove.

Casualty record · 1

26 August 2011Routine · role: Involved in a Marine Casualty · activity 4144038
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.