MAURY USCG vessel records Sign in
← All vessels

HERRING

HERRING is a 1979 offshore supply vessel. The Coast Guard has recorded 48 inspections since 1989, most recently in February 2025, along with 27 deficiencies and 1 casualty investigation in 2011.

Records from 1989 to 2025. Most recent: inspection, 6 February 2025.

Built
1979
Last inspected
6 February 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7948421 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH4834
177830
Flag
UNITED STATES
366947780, 367032590, 367621850 (licence lapsed)
Maury page id
psix-177830

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1989–2025)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)71.5 ft × 32.0 ft × 6.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH4834MMSI 367621850 · expired · compulsorily equipped · granted 17 May 2014, cancelled 20 July 2024
WDC4907MMSI 367032590 · expired · compulsorily equipped · granted 9 April 2005, cancelled 13 June 2015
WDB7771MMSI 366947780 · expired · compulsorily equipped · granted 14 May 2004, cancelled 19 July 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 48

6 February 2025 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8038105
6 September 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7786261
19 July 2022 Drydock Exam · Periodic Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7510728
20 July 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7344875
20 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7178902
12 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7094321
9 November 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7092314
25 June 2020 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6991690
9 June 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6981047
20 June 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6720195
23 April 2019 Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6668620
27 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5921051
23 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4229864
22 September 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4151124
26 August 2011 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4144038
6 January 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3921819
7 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3645757
18 September 2008 Ballast Water Examination · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3327196
6 September 2007 Hull Examination · Internal Structural Exam · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3050453
7 September 2006 COI Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2771610
1 December 2005 Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2545954
23 November 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539885
15 December 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260105
26 July 2004 Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2145293
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972232
26 November 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1955569
22 July 2002 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1650354
9 August 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379533
13 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118695
21 July 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423204
17 August 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396978
16 July 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441270
28 August 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460026
16 August 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374363
16 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 865938
27 June 1994 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412670
4 October 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 846750
27 July 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448441
2 September 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 959461
23 June 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473255
13 June 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037177
24 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912366
24 September 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211404
23 July 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234622
7 February 1990 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921411
2 February 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241054
4 December 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901891
31 May 1989 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889618

Deficiency record · 27

02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 6 September 2023 Resolved
The owner of a vessel shall ensure the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. During inspection of the engine room cracked welds were identified in the vicinity of the port and starboard generator exhaust trunks. A crack was identified on the starboard side where the exhaust trunk penetrated the main deck causing water ingress. Vessel is to repair all cracks and perform non destructive testing on welds in the water tight envelope prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2023
Resolution: Vessel repaired and tested areas called out. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2022 Resolved
The minimum capacity of the power fire pump must not be less than 60psi. Fire pump did not meet 60psi. Repair or replace fire pump to reach 60psi
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 27 July 2022
Resolution: Vessel rep provided photographic and video evidence of operable fire pump
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 July 2022 Resolved
All installed equipment must operate as designed. Fire detection panel on the bridge visual alarms were INOP. Repair to make operational.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 27 July 2022
Resolution: Vsl rep provided photographic and video evidence of working detection panel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2022 Resolved
During every drydock exam, the "leg to can" connection welds and the "can-pad" connection welds should be Non-destructively tested (NDT). Vessel did conduct NDT. Conduct NDT and provide report.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 28 July 2022
Resolution: Vsl rep provided report of NDT
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 July 2022 Resolved
The master or person in charge shall ensure that each crane is operated and maintained in accordance with API 2D. Crane was being serviced and was inoperable. Provide report of crane repair.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2022
Resolved 28 July 2022
Resolution: Vsl rep provided crane report from third party.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the end of the fuel line to stop fuel flow when servicing accessories. The shut off valve at the tank shall be operable from outside the tank compartment. During inspection it was discovered that the emergency fuel shut valves for the port and starboard fuel tanks were altered and moved to a secondary valve, approximately 5' from the valve installed at the fuel tanks. Vessel shall alter placement of emergency fuel shut off valves to be located at the closest valve to the fuel tanks. Vessel surpassed previous 14 day deadline issued on 835V from 09JUN2020 inspection. Vessel did not communicate needs for any additional time needed for correction of issued deficiency above. Additionally, vessel representative stated they will not fix until they "decide to pull out for service". The decision to not correct the issued deficiency shows the company is not proactively managing the potential fire hazard identified onboard. Vessel may not move from its present location or operate any machinery onboard until corrected. Vessel shall schedule a deficiency check inspection when corrections are made to ensure on site verification is completed to the satisfaction of the attending marine inspector. 46CFR182.20-40(b)(3)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 July 2020
Resolution: Received video evidence of remote fuel shut off valves moved to proper location.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the end of the fuel line to stop fuel flow when servicing accessories. During inspection it was discovered that the emergency fuel shut valves for the port and starboard fuel tanks were altered and moved to a second valve, approximately 5' from the valve installed at the fuel tanks. Vessel shall alter placement of emergency fuel shut off valve to be located at the closest valve to the fuel tanks. 46CFR182.20-45(b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 25 June 2020
Resolution: Vessel did not meet timeline or request additional time. Vessel is not proactively managing deficiency. A new deficiency was issued with a code 60 to correct prior to movement. See activity 6981047.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2019 Resolved
The number and identification of the lifejackets must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Lifejackets that were located in accomodation spaces required labeling to identify thier location and number avaialble. 46 CFR 185(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2019
Resolved 24 June 2019
Resolution: Lifejacket locations and quantities were placarded.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 20 June 2019 Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Aft pilothouse window was damaged not allowing a clear view for navigation. 46 CFR 177.1030
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2019
Resolved 24 June 2019
Resolution: Pilothouse window was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 20 June 2019 Resolved
Stove sea rails require suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Newly installed stove did not contain sea rails. 46 CFR 184.220(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2019
Resolved 7 July 2019
Resolution: Sea rails were provided for new stove.
Fire Fighting › Fire Main › Condition
Issued 22 September 2011 Resolved
Fire Main overhead line in the stbd side engine room was not secured. Old brackets were not attached to the overhead deck. Reweld Fire Main brackets to overhead to secure Fire Main line.
Due 22 October 2011
Resolved 23 October 2011
Resolution: Brackets were welded to the overhead deck to secure Fire Main line in the Stbd side engine room.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 22 September 2011 Resolved
Place double clamps on all coolings and hydraulic lines on both MDEs.
Due 22 October 2011
Resolved 23 September 2011
Resolution: Double clamps placed on lines.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 September 2011 Resolved
Place guards over rotating equipment on both MDEs.
Due 22 October 2011
Resolved 23 September 2011
Resolution: Metal plates attached by bolts to guard the rotating machinery on both MDEs.
Engineering › Bilge Water Management System › Pump
Issued 22 September 2011 Resolved
Stbd side bilge pump was not operating. Properly operate s/s bilge pump.
Due 3 October 2011
Resolved 23 September 2011
Resolution: S/S Bilge pump operates properly.
Communications › Alarms/Indicators › Fire Alarm
Issued 22 September 2011 Resolved
General alarm and fire alarms were not correctly labeled. Fire alarms were labeled G.A. and vice versa. Correct labeling on all alarms.
Due 3 October 2011
Resolved 23 September 2011
Resolution: All alarms correctly labled.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 September 2008 Resolved
Switchboard box missing plugs. Wires had been removed at some time in the past and the holes in the box for wires had not been plugged.
Action required: 705 - Other - as specified
Resolved 24 June 2019
Resolution: Plugs placed on box ensuring water tightness
Engineering › Bilge Water Management System › Not Operational
Issued 18 September 2008 Resolved
Provide 3rd party service report for satisfatory testing of bilge alarms
Action required: 705 - Other - as specified
Resolved 24 June 2019
Resolution: Received fax report from 3rd party indicating crew had not tested system properly.
Engineering › Lubricating Oil Service System › Piping
Issued 7 September 2006 Resolved
Demonsta=rate hydraulic system and components comply with 46 CFR 58.30 & 58.30 as required by NVIC 8-91, also that the system is "fail safe".
Action required: 705 - Other - as specified
Due 7 September 2007
Resolved 18 September 2008
Resolution: Vessel provided documentaiton indicating substantial compliance. Letter included in Operations Manual on the vessel.
Stability › Freeing Ports › General
Issued 1 December 2005 Resolved
Provide approved KG curve in operations manual. Rep. stated that KG curve has been submitted to MSC and they are awaiting the results.
Action required: 705 - Other - as specified
Due 1 February 2006
Resolved 7 September 2006
Resolution: Provided.
Lifesaving
Issued 21 July 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 21 July 1999
Resolved 21 July 1999
Unknown
Issued 4 December 1989 Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Unknown
Issued 4 December 1989 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENTS, INBOARD/OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Unknown
Issued 4 December 1989 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Unknown
Issued 31 May 1989 Resolved
PROVIDE APPROVED STRUCTURAL AND ENGINEERING PLANS FOR SUBJECT VESSEL.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Documentation
Issued 31 May 1989 Resolved
PROVIDE COAST GUARD APPROVED STABILITY LETTER/BOOKLET.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Documentation
Issued 31 May 1989 Resolved
PROVIDE COAST GUARD APPROVED OPERATING MANUAL.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Documentation
Issued 31 May 1989 Resolved
PROVIDE COPY OF CORRECTED CERTIFICATE OF DOCUMENTATION (DOC) TO REFLECT CHANGES IN ADMEASUREMENT.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989

Casualty record · 1

26 August 2011Routine · role: Involved in a Marine Casualty · activity 4144038
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.