← All vessels

RESPONDER

RESPONDER is a 2000 industrial vessel. The Coast Guard has recorded 6 inspections since 2003, most recently in June 2017, along with 9 deficiencies and 1 operational control.

Records from 2003 to 2017. Most recent: inspection, 5 June 2017.

Built
2000
Last inspected
5 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9215206 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SOUTH KOREA
—
Maury page id
psix-17877

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2003–2017)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it8071 - Dead Weight, Ton
12539 - Displacement, Ton
6204 - Regulatory (Subpart C or D), Gross Ton
6298 - Convention (Subpart B), Gross Ton
1887 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 6

5 June 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6165748
23 January 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075271
5 January 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065985
9 November 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5758428
26 September 2004 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2202881
17 March 2003 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1757638

Deficiency record · 9

Fire Fighting › Structural - A Class Divisions › Stairways
Issued 5 January 2017 Resolved
0750-15AC-SOLAS74(14)II-2/14.2.1.1.1 STRUCTURAL FIRE PROTECTION, INCLUDING FIRE RESISTING DIVISIONS SHALL BE KEPT IN GOOD ORDER TO PREVENT THE PASSAGE OF FIRE. A-0 BULKHEAD HAD AN IMPROPER PENETRATION OF A CONDENSATION PIPE FROM A RECENTLY INSTALLED A/C UNIT. MATERIAL USED TO SEAL PENETRATION WAS SILICONE.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 January 2017
Resolution: Recieved report from KR class attesting to the proper repair of the A0 boundry. Condensing lines were removed and a plate was welded sealing the bulkhead to maintain the fire boundry.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 5 January 2017 Resolved
1020-10c-SOLAS 74(14)II-2/14.2.1.1.2 FIRE DETECTION EQUIPMENT SHALL BE KEPT IN GOOD WORKING ORDER. A MANUAL CALL POINT IN THE E/R NEXT TO THE OWS WAS FOUND TO BE DISCONNECTED.
Due 5 January 2017
Resolved 5 January 2017
Resolution: CREW REPAIRED CALL POINT PRIOR TO END OF EXAM AND USCG PERSONNEL WITNESSED PROPER OPERATIONAL TEST OF MANUAL CALL POINT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 November 2015 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Cables, wiring, and lighting installations are not installed in a manner to avoid chafind or damage in the paint locker and adjacent store room. 74 SOLAS(2001 Cons) II-1/45.5.5 Code: 50 (b)(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 5 January 2017
Resolution: USCG VERIFIED CLASS REPORT OF REPAIRS AND VISUAL INSPECTION OF REPAIRS.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 9 November 2015 Resolved
Main and emergency switchboards shall be arranged as to give easy access without danger to personnel. Nonconductive mats were not provided for the switchboards. 74 SOLAS (2001 Cons) II-1 / 45.2 Code: 50 (b)(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 5 January 2017
Resolution: USCG VERIFIED NONCONDUCTIVE MATS AT ALL SWITCHBOARDS ONBOARD.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 November 2015 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proced to sea without danger to the ship or persons on board. The alarm sensors on the fixed CO2 System's incinerator system are loose and not operating correctly. 74 SOLAS(2014 CONS) I / 11(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 5 January 2017
Resolution: USCG VERIFIED CLASS REPORT OF REPAIRS.
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2004 Resolved
No paper marine charts, only electronic copies.
Action required: 705 - Other - as specified
Resolved 26 September 2004
Resolution: Vessel recieved marine charts, while USCG MI conducting PII exam.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 26 September 2004 Resolved
No Manuvering fact sheet on board
Action required: 705 - Other - as specified
Resolved 26 September 2004
Resolution: Vessel provided manuvering fact sheet, to USCG MI during PII exam.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 September 2004 Resolved
Water tight door on port side, main deck leading to engine room was found not able to close properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 September 2004
Resolution: Crew made repairs to door, while USCG MI conducted PII exam.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 26 September 2004 Resolved
Steering gear room did not have posted switch over procedures for remote steering steering gear controls.
Action required: 705 - Other - as specified
Resolved 26 September 2004
Resolution: Vessel provided switch over procedures to USCG MI during PII exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.