← All vessels
RESPONDER
Industrial Vessel · Miscellaneous Vessel class · Built 2000s · USCG Oceania District (CGD-O) · Other hulls named RESPONDER
RESPONDER is a 2000 industrial vessel. The Coast Guard has recorded 6 inspections since 2003, most recently in June 2017, along with 9 deficiencies and 1 operational control.
Records from 2003 to 2017. Most recent: inspection, 5 June 2017.
- Built
- 2000
- Last inspected
- 5 June 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9215206 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D7AW
17877
Flag
SOUTH KOREA
—
Maury page id
psix-17877
Inspections, by type
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Tonnage as PSIX records it8071 - Dead Weight, Ton
12539 - Displacement, Ton
6204 - Regulatory (Subpart C or D), Gross Ton
6298 - Convention (Subpart B), Gross Ton
1887 - Convention (Subpart B), Net Ton
12539 - Displacement, Ton
6204 - Regulatory (Subpart C or D), Gross Ton
6298 - Convention (Subpart B), Gross Ton
1887 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 6
5 June 2017
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6165748
23 January 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075271
5 January 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065985
9 November 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5758428
26 September 2004
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2202881
17 March 2003
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1757638
Deficiency record · 9
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 5 January 2017
Resolved
0750-15AC-SOLAS74(14)II-2/14.2.1.1.1 STRUCTURAL FIRE PROTECTION, INCLUDING FIRE RESISTING DIVISIONS SHALL BE KEPT IN GOOD ORDER TO PREVENT THE PASSAGE OF FIRE. A-0 BULKHEAD HAD AN IMPROPER PENETRATION OF A CONDENSATION PIPE FROM A RECENTLY INSTALLED A/C UNIT. MATERIAL USED TO SEAL PENETRATION WAS SILICONE.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 5 January 2017
Resolved
1020-10c-SOLAS 74(14)II-2/14.2.1.1.2 FIRE DETECTION EQUIPMENT SHALL BE KEPT IN GOOD WORKING ORDER. A MANUAL CALL POINT IN THE E/R NEXT TO THE OWS WAS FOUND TO BE DISCONNECTED.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 November 2015
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Cables, wiring, and lighting installations are not installed in a manner to avoid chafind or damage in the paint locker and adjacent store room.
74 SOLAS(2001 Cons) II-1/45.5.5
Code: 50 (b)(c)
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 9 November 2015
Resolved
Main and emergency switchboards shall be arranged as to give easy access without danger to personnel. Nonconductive mats were not provided for the switchboards.
74 SOLAS (2001 Cons) II-1 / 45.2
Code: 50 (b)(c)
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 November 2015
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proced to sea without danger to the ship or persons on board. The alarm sensors on the fixed CO2 System's incinerator system are loose and not operating correctly.
74 SOLAS(2014 CONS) I / 11(a)
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2004
Resolved
No paper marine charts, only electronic copies.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 26 September 2004
Resolved
No Manuvering fact sheet on board
Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 September 2004
Resolved
Water tight door on port side, main deck leading to engine room was found not able to close properly.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 26 September 2004
Resolved
Steering gear room did not have posted switch over procedures for remote steering steering gear controls.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.