AK-2938-AX is a 2023 passenger vessel (inspected). The Coast Guard has recorded 6 inspections since 2023, most recently in May 2025, along with 2 deficiencies.
Records from 2023 to 2025. Most recent: inspection, 25 May 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it1 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 6
25 May 2025In-Service Inspection · Administrative Inspection
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 November 2024Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel missed required annual inflation tests per D13/D17 Policy Letter 16711. The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel missed required annual inflation tests per D13/D17 Policy Letter 16711.
46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2025
Resolution: Conducted inflation test. See AN: 8083975
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2023Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Floating waterlight had an expired battery installed and was found with significant water intrusion.
46 CFR 180.70(d)
Action required: 10 - Deficiency Rectified
Resolved 16 July 2023
Resolution: Waterlight was replaced.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.