← All vessels
NACC VEGA
NACC VEGA is a 2010 freight ship. The Coast Guard has recorded 8 inspections since 2023, most recently in October 2025, along with 23 deficiencies — 2 with no resolution recorded — and 2 operational controls.
Records from 2023 to 2025. Most recent: inspection, 8 October 2025.
- Built
- 2010
- Last inspected
- 8 October 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9486336 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO8465
1793048
Flag
PANAMA
—
Maury page id
psix-1793048
Inspections, by type
…with no type recorded1
…past their stated due date2
Years with a record
2 calendar years (2023–2025)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it5566 - Convention (Subpart B), Gross Ton
7779 - Dead Weight, Metric Ton
10704 - Displacement, Metric Ton
2147 - Convention (Subpart B), Net Ton
7779 - Dead Weight, Metric Ton
10704 - Displacement, Metric Ton
2147 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
8 October 2025
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8245500
7 October 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8249679
6 December 2023
Appeal
Administrative · Commandant (CG-CVC) · Activity 7834426
4 December 2023
PSC A · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7831384
29 November 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7831462
9 September 2023
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7785199
21 August 2023
Deficiency Check · Administrative Inspection · PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7770863
18 August 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7771357
Deficiency record · 23
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 8 October 2025
No resolution recorded
This regulation shall apply to: 1. each marine diesel engine with a power output of more thatn 130kW installed on a ship. EIAPP certificate not provided.
MARPOL Annex VI, 13.1.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2025
Resolved
Each seperate circuit shall be protected against short circuit and against overload. 02 overloaded circuits identified on bridge.
74SOLAS2004 II-1 45.6.1
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 October 2025
Resolved
All life-saving appiances and arrangements shall comply with the applicable requirements of the code. All lifesaving appliances prescribed in this part shall... Be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the organization. Life buoys on each bridge wing and lifeboat were weathered.
74 SOLAS 2004, III 34
LSA 1.2.2.7
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 October 2025
No resolution recorded
Escape routes shall be maintained in a safe condition, clear of obstacles.
Refrigerator door, leading into vegetable room, has an inoperable handle, impeding means of escape.
74SOLAS2004 II-2 13.1.2
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 December 2023
Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. DURING THE TESTING OF THE SMOKE DETECTOR ABOVE HFO SEPERATOR NO.1, PSCO OBSERVED THE DETECTOR ACTIVATE BUT WAS UNABLE TO BE SILENCED OR ACKOWLEDGE, RENDERING THE REMAINING 5 SMOKE DETECTORS IN THAT ZONE INCAPABLE OF BEING TESTED. SOLAS74(04)II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 December 2023
Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: STRUCTURAL FIRE PROTECTION INCLUDING FIRE-RESISTING DIVISIONS, AND PROTECTION OF OPENINGS AND PENETRATIONS IN THESE DIVISIONS. PSCO OBSERVED CLASS A BOUNDARY WITH INSULATION IN DISREPAIR AND A CABLE RUN INADEQUATLEY SEALED IN DRY STORES. SOLAS74(04)II-2/14.2.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 December 2023
Resolved
DURING PREPARATION AND LAUNCHING THE SURVIVALCRAFT, ITS LAUNCHING APPLIANCE, AND THE AREA OF WATER INTO WHICH IT IS TO BE LAUNCHED SHALL BE ADEQUATELY ILLUMINATED BY LIGHTING SUPPLIED FROM THE EMERGENCY SOURCE OF ELECTRICAL POWER REQUIRED BY II-1/42 OR II-1/43 AS APPROPRAITE. PSCO OBSERVED NO LIGHTING ARRANGEMENT AT THE FORWARD LIFERAFT CAPABLE OF LIGHTING THE LAUNCHING APPLIANCE AND THE AREA OF WATER WHICH IT IS TO BE LAUNCHED. SOLAS74(20)III/16.7
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 December 2023
Resolved
OIL RECORD BOOK SHALL BE IN THE FORM SPECIFIED IN APPENDIX III TO THIS ANNEX. APPENDIX III REFERS TO MEPC.1/CIRC.736/REV.2 ANNEX PAGE 1: IF A WRONG ENTRY HAS BEEN RECORDED IN THE OIL RECORD BOOK (ORB) IT SHOULD IMMEDIATELY BE STRUCK THROUGH WITH A SINGLE LINE IN SUCH A WAY THAT THE WRONG ENTRY IS STILL LEGIBLE. PSCO OBSERVED ENTRIES IN THE ORB WHITED OUT. MARPOL ANNEX 1/17.1
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 September 2023
Resolved
Fire-fighting systems and appliances shall be kept in good order and readily available for immediate use. PSCO observed releasing control for CO2 cylinder to engine room was not readily available for immediate use due to being zip-tied in closed position. Pneumatic piping is not intact due to missing nozzle caps. Flexible discharge hose and fitting was not attached/secured to CO2 cylinder. SOLAS 74 (04)II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2023
Resolved
Maintenance testing and inspection shall be carried out based on the guidelines developed by the organization, and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. On board maintenance inspections are not being carried out in accordance with the ship's maintenance plan, which shall include the minimum requirements of sections 4 through 10 of MSC.1/CIRC.1432 Annex. Existing maintenance plan did not include minimum requirements along with objective evidence that required maintenance, testing and inspections have been carried out to those standards.
SOLAS 74 (04) II-2/14.2.2.1
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2023
Resolved
A fixed fire detection and fire alarm system and a sample extraction smoke detection system required in this regulation and other regulations in this part shall be of an approved type and comply with the Fire Safety Systems Code. Suitable testing and component spares for testing and maintenance shall be provided. Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. Chief Engineer stated the vessel does not have the proper equipment to test the flame detectors properly.
SOALS 74 (04) II-2/2.2.2 FSS Code 9.2.5.2
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2023
Resolved
The maintenance plan shall include those fire protection systems and firefighting systems and appliances in accordance with regulation 14.2.2.3. PSCO discovered maintenance plan does not address installed water mist system or EEBDs maintenance elements.
SOLAS 74 (20) II-2/14.2.2.3
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 21 August 2023
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with additional requirements which may be established by the company. Due to the deficiencies of a technical and/or operational nature identified below which individually or collectively provides objective evidence of the ISM code. An external audit shall be conducted by the Flag Administration before the vessel will be released from its detention to determine whether the vessel is operating in compliance with the ISM code. A copy of the completed external audit shall be provided to this office for review prior to departure from the port of Pensacola. (74SOLAS (20) IX/3.1 ISM Code Part A/10.1)
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 August 2023
Resolved
Before the ship leaves port and at all times during the voyage all life saving appliances shall be in working order and ready for immediate use. PSCO observed rescue boat engine unable to start. (74SOLAS (20) III/20.2)
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 August 2023
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. PSCO observed during the testing of the emergency generator, that the emergency generator was not providing sufficient voltage or Hz to supply the emergency switchboard. (74SOLAS (04) II-1/43.2)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. PSCO observed that fire boundary doors, in vessel stairway enclosure, were unable to close and latch properly. (74SOLAS (04) II-2/14.2.1.1)
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 21 August 2023
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained and ready for use. PSCO observed washers for international shore connection missing.
(74SOLAS (04) II-2/14.1.1 FSS Code 2.2.2)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2023
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed stuffing tubes on the service diesel generator were loose and not maintaining cable strain. PSCO also observed light switch in hospital space not secured properly. (74SOLAS (04) II-1/45.1.3)
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 21 August 2023
Resolved
Steering gear compartment arrangements shall include handrails and gratings or other non-slip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. PSCO observed no gratings, mats, or other means of providing a non-slip surface in the steering gear room. (74SOLAS (04) II-1/29.13.2)
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 August 2023
Resolved
Simple operating instructions with a block diagram showing the change over procedures for remote steering gear control systems and steering gear power units shall be permanently displayed on the navigation bridge and in the steering compartment. PSCO observed no block diagram posted in steering gear room. (74SOLAS (20) V/26.3.1)
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 21 August 2023
Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered taking into account the guidelines developed by the organization. PSCO requested fuel oil samples but the vessel could not locate the two most recent bunkering samples. (MARPOL VI/18.8.1)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 August 2023
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed, and maintained in compliance with the mechanical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI/1, or with the applicable national standards of the Administration which provide an equivalent level of safety. PSCO observed acetylene and oxygen cylinders not secured in rack and missing caps. (74SOLAS (04) II-1/3-1)
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 21 August 2023
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter. Vessel was unable to provide transfer procedures that met the aforementioned requirements to the PSCO. (33 CFR 155.720)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.