Records from 2002 to 2023. Most recent: inspection, 31 October 2023.
Documentation record
Registered dimensions (L × B × D)51.5 ft × 20.0 ft × 7.0 ft
Registered tonnagegross 64 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO CORP · PINE BLUFF, AR, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portRAYLAND, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
31 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7818168
21 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7512771
11 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7448495
27 November 2020
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7367187
11 December 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6889414
27 November 2018
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6588521
26 December 2013
Damage Survey · Marine Casualty Follow Up
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4776767
25 December 2013
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4778996
5 January 2011
DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3921254
15 December 2009
Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3660867
17 November 2009
Marine Casualty Follow Up · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3639623
16 November 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3638488
28 August 2002
Uninspected Towing Vessel · Administrative Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1668887
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2022
No resolution recorded
Ring buoys are beyond service life. A towing vessel of at least 26' but less than 79' in length must carry a minimum of 2 lifebuoys of at least 24" in diameter, with the proper attachments and markings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 May 2022
No resolution recorded
A vessel on a rivers route must carry 3 day and 3 night visual distress signals. Vessel did not have the required day and night visual distress signals. Supply the vessel with adequate number of visual distress signals and provide proper storage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2022
No resolution recorded
Each towing vessel must be equipped with an industrial type first aid cabinet or kit. The kit found onboard has expired items inside. Replace kit or expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 May 2022
No resolution recorded
Portable fire extinguisher in lounge does not fit in the bracket. Provide bracket to correctly mount the fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 May 2022
No resolution recorded
Portable fire extinguisher gauge in the workboat showing as undercharged. Refill or replace fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 May 2022
No resolution recorded
Records of drills and instruction must be maintained to include the (1) date of the drill/instruction, (2) a description of the drill scenario/instruction topics, and (3) the personnel involved. Records of drills missing. Provide documentation of emergency drills/instruction conducted for fire, man overboard, abandoning the vessel, responding to onboard flooding, and responding to other threats to life, property or the environment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 May 2022
No resolution recorded
Properly install the bracket for the port engine driven steering pump. To be addressed at the next credit dry dock, 30Nov2023.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2023 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2022
No resolution recorded
Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve, located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The valve must be clearly marked by labeling or color coding that enables the crew to identify its function. Ensure all hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel, are installed with closure devices at next credit dry dock, 30Nov2023.
Condition: Improper Installation
Action required: 705 - Other - as specified