Records from 2002 to 2012. Most recent: operational control imposed, 10 February 2012.
Inspection history · 44
10 February 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4242134
10 February 2012
ISPS I Exam · COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4242242
27 January 2012
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4232978
13 January 2012
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4224457
26 December 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4213974
9 December 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4205289
28 September 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4156511
15 September 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4145673
31 August 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4131995
18 August 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4117019
16 August 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4117159
3 August 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4104012
20 July 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4088013
6 July 2011
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4071821
15 February 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3945774
2 February 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3937974
20 January 2011
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3929531
7 January 2011
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3922455
23 December 2010
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3915388
9 December 2010
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3907663
24 November 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3899297
12 November 2010
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3889745
11 November 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3889330
26 October 2010
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3878237
14 October 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3869619
1 October 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3860987
20 September 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3853362
18 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3851997
18 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3852328
15 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3850672
3 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3841336
3 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3841343
2 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3840348
2 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3840899
5 October 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3073164
9 September 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3053519
30 October 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2810539
23 March 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2608373
2 March 2006
Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594999
11 February 2006
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2583458
20 January 2006
Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2597446
18 January 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2569062
7 November 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2530071
22 February 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1488619
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 August 2011
Resolved
0950 All electric apparatus shall be so maintained as not to cause injury when handled or touched in the normal manner. Dead end wiring found in engine room. SOLAS 74' (04 Cons) II-1 Reg 45.1.3 50(c)
Action required: 705 - Other - as specified
Due 18 September 2011
Resolved 29 August 2011
Resolution: Received picture from captain of dead end electrical wiring removed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 18 August 2011
Resolved
0710 Machinery and equipment and fittings shall be designed and constructed adequate for their intended service and install to reduce any danger to persons on board, hot surfaces. Sludge return pipe has worn and missing insulation.
SOLAS 74' (01 Cons) II-1 Reg 26.1 (50)c
Action required: 705 - Other - as specified
Due 18 September 2011
Resolved 29 August 2011
Resolution: Received picture from agent attesting to replacement of insulation.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 18 August 2011
Resolved
0710 Arrangements for storage, distribution and utilization of oil fuell shall ensure the safety of crew and ship. Sludge return pipe leaking sludge at pipe connection point. SOLAS 74' (97 Cons) II-2 Reg 15.2 (50)c
Action required: 705 - Other - as specified
Due 18 September 2011
Resolved 29 August 2011
Resolution: Received picture from agent showing the gasket was replaced on the sludge return pipe.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 18 August 2011
Resolved
0150 After survey, no change made to the equipment without sanction of the Administration. Condition of equipment shall be maintained to conform with the provisions of this convention. Incenerator inoperable. IOPP Certificate states the vessel has an incinerator. MARPOL Annex I Reg 44 10(c)
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 18 August 2011
Resolution: Crew was able to successfully operate the incinerator.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 9 September 2007
Resolved
Incinerator fails to ignite when attempting to start.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2007
Resolution: The Master presented a Class [name withheld] stating "The incinerator was presented operational and tested satisfactory to the class Surveyor."
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 30 October 2006
Resolved
EMERGENCY GENERATOR DOES NOT START AUTOMATICALLY UPON FAILURE OF THE MAIN SOURCE OF ELECTRICAL POWER DUE TO AN INOPERABLE "Q2" BREAKER LOCATED BETWEEN THE3 MAIN SWITCH BOARD AND THE EMERGENCY GENERATOR.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 November 2006
Resolved 20 November 2006
Resolution: Received class report that states a new breaker was installed & a blackout test was carried out to demonstrate proper operation of the switchgear.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 November 2005
Resolved
Vssl currently installing new S-Band radar. Proof of completed installation and proper operation to be provided to COTP LA/LB prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2005
Resolved 8 November 2005
Resolution: Rcvd technician report via fax stating that the radar was installed and operating properly.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 22 February 2002
Resolved
VARIATION BETWEEN GYROCOMPASS AND MAGNETIC 20DEG LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2005
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 22 February 2002
No resolution recorded
MANUVERING FACT SHEET DOES NOT CONTAIN -WARNING STATEMENT-
Action required: 17 - Rectify deficiencies prior to departure
Resolution: WHILE ON BOARD CORRECTED
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 February 2002
No resolution recorded
PLACARD NEEDS APPROVAL PLACARD AFFIXED TO MSD
Action required: 17 - Rectify deficiencies prior to departure
Resolution: CORRECTED WHILE ON BOARD
Fire Fighting › International Shore Connection
Issued 22 February 2002
No resolution recorded
NOT IN ACCORDANCE WITH FIRE CONTROL PLAN LOCATION
Action required: 17 - Rectify deficiencies prior to departure
Resolution: CORRECTED WHILE ON BOARD
Lifesaving › Buoyant Smoke Signals
Issued 22 February 2002
No resolution recorded
NO EXPIRATION DATE INDICATED
Action required: 17 - Rectify deficiencies prior to departure
Resolution: CORRECTED WHILE ON BOARD
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 February 2002
No resolution recorded
INOPERABLE / PORTSIDE STERN
Action required: 17 - Rectify deficiencies prior to departure
Resolution: CORRECTED WHILE ON BOARD
Engineering › Lubricating Oil Storage/Transfer System
Issued 22 February 2002
No resolution recorded
PIPING DIAGRAM MISSING FROM TRANSFER PROCEEDURES
Action required: 17 - Rectify deficiencies prior to departure
Resolution: CORRECTED WHILE ON BOARD