MAURY USCG vessel records Sign in
← All vessels

JOHANN JACOB

JOHANN JACOB is a 2000 tank ship. The Coast Guard has recorded 45 inspections since 2002, most recently in February 2018, along with 12 deficiencies and 10 operational controls.

Records from 2002 to 2018. Most recent: inspection, 27 February 2018.

Built
2000
Last inspected
27 February 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9189134 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-18038

Inspections, by type

…with no type recorded14
Years with a record 15 calendar years (2002–2018)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it73071 - Dead Weight, Metric Ton
86133 - Displacement, Metric Ton
40037 - Convention (Subpart B), Gross Ton
20900 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DEBORAH ANN Towing Vessel · MISLE 108607 · 6 February 2003 · activity 1743586TL 202 Freight Barge · MISLE 371480 · 6 February 2003 · activity 1743586

Inspection history · 45

27 February 2018 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6360182
23 February 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6360176
18 March 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6103210
24 February 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5820952
23 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5820026
14 February 2016 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5810118
13 October 2014 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5000891
15 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4345257
11 June 2012 ISPS III Exam · Ballast Water Examination · Deficiency Check · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4340409
12 September 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4142574
12 September 2011 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4142929
11 July 2011 Ballast Water Examination · ISPS III Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4071967
10 November 2010 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3888146
17 February 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3679460
20 July 2009 COC-TVE Annual · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3534665
18 July 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3538359
21 February 2009 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3421520
8 February 2009 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3412489
31 July 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3284751
1 June 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Renew · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3223653
29 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3155678
29 February 2008 ISPS III Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3155753
18 January 2008 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3141562
3 July 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2982358
20 June 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2968424
29 May 2007 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2944625
10 June 2006 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2675729
6 April 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2618350
23 November 2005 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2539746
26 September 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2497784
30 July 2005 ISPS III Exam · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2444972
22 March 2005 ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2316505
5 March 2005 MARPOL Annex I Examination · NPV Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2303517
16 February 2005 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2293661
11 February 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2292753
7 February 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2291009
2 December 2004 PII Safety Exam · Ballast Water Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2247943
1 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2251386
9 July 2004 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2124611
2 June 2004 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2086472
8 October 2003 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1923967
13 August 2003 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1868127
23 May 2003 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1799672
6 February 2003 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1743586
2 June 2002 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1623335

Deficiency record · 12

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 11 June 2012 Resolved
1199 - Other (cargo) - Upon beginning COC exam vessel was discharging cargo. Cargo pump room must be examined prior to discharge at next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 June 2012
Resolution: Examined Pump Room found satisfactory.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 June 2012 Resolved
0670 - Portable radio app. for surv. Craft - Emergency GMDSS radios are missing spare batteries. Radios are required to have a spare battery. Rectify deficiency within 14 days to satisfaction of Class/Administration. SOLAS Ch. III/6.2.1.1; IMO Resolution A.809(19)
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 12 June 2012
Resolution: Received ABS class report #NY2161418 stating that three (3) spare batteries were replaced with the following expiration dates two (2) batteries: May 2017; one (1) battery: July 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 11 June 2012 Resolved
1830 - Cargo transfer - All cargo hoses and equipment not in use must be flanged. Cargo spool piece on port side was not flanged and leaking cargo on deck.
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 11 June 2012
Resolution: PSC team raised the issue with the mate on watch who promptly cleaned the area and prevented further discharge from the used piece of equipment. Also addressed the issue with the Master and Chief Engineer.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 June 2012 Resolved
2035 - Fire control plan - Door closure from crew's mess to crew's pantry was removed. Fire control plan indicates door as a self-closing "A" class fire door. Rectify deficiency within 14 days to satisfaction of Class / Administration. SOLAS (2001 Consd.) II-2/20
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 12 June 2012
Resolution: Received ABS class report #NY2161418 stating that the door self closing device leading from the crew mess to the crew pantry was re-installed and working at this time.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 11 June 2012 Resolved
0690 - Line throwing apparatus - Line throwing devices on bridge are all expired. Replace with line throwing devices that are not expired. Rectify deficiency prior to departure to the satisfaction of Class / Administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2012
Resolution: Received ABS class report #NY2161418 stating that all 4 line throwing devices were verified to have an expiration date of October 2014.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 20 July 2009 Resolved
Turbocharger for the #2 Auxiliary Engine was removed rendering the engine inoperable. The Turbocharge for Auxiliary Engine #1 is also inoperable, causing a reduced load capacity of 300kw.
Action required: 705 - Other - as specified
Due 20 July 2009
Resolved 28 July 2009
Resolution: Recvd Class report attesting to repairs and proper operations of all generators.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 June 2008 Resolved
Replace cracked explosion proof light fixture lens covers (04 Total), located in port/starboard amidships lockers. Fax purchase receipt to USCG NLT 02JULY08.
Action required: 705 - Other - as specified
Due 2 July 2008
Resolved 24 July 2008
Resolution: Rcvd fax report from Class attesting to purchase of new lens covers.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 29 February 2008 Resolved
A river barge broke loose and collided with the vessel's port bow. Vessel was restricted to IMTT St. Rose, MM 118, Lower Mississippi pending class surveyor attesting to the integrity of the vessel.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 29 February 2008
Resolution: Received class report from ABS attesting that the vessel did not sustained any damage from the collision. Class surveyor stated: From the deck of a river launch boat, the port side of the bow was close-up examined and found no aparent impact damage.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 May 2007 Resolved
Garbage Plan not Ship Specific; A. Does not specify how containers should be labelled or color coded for each type of garbage. B. Does not specify Incinerator operattion, what can be burned and how ash showed be disposed of. C. Disposal procedures for Medical waste, batteries & lamps. D. Plan lists a garbage grinder that is not onboard vessel. There is no record of incinerator ash disposal. 70ab.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 July 2007
Resolution: Deficiency cleared, based on receipt of Class report dated 15 JUN 07.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 May 2007 Resolved
The flourescent intrinsically safe light fixture stbd side upper deck level is full of water, deteriorated & inoperable. (70 ab)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 July 2007
Resolution: Deficiency cleared, based on receipt of Class report dated 15 JUN 07.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 May 2007 Resolved
Red Navigation / Signal light has a painted lense & red household low wattage light bulb. Class to determine proper installed equipment required. (70ab)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 July 2007
Resolution: Deficiency cleared, based on receipt of Class report dated 15 JUN 07.
Construction/Loadline › Hull › Hull Plating
Issued 13 August 2003 Resolved
Insest's and buckled longitodinals IWO 1 SWBT/PWBT to Specially addressed at UWILD by 30SEP03. Class report to be submitted to cognizant COTP Recomendation for approval/continuance based on class report and OCMI conurrence. LEGACY COMPONENT DESC: Longitudinal Frame
Due 30 September 2005
Resolved 9 July 2004
Resolution: Reviewed class report approving temporary repairs until vessels next scheduled dry dock in 2005.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.