MAURY USCG vessel records
← All vessels

CONCH QUEST

CONCH QUEST is a 1979 passenger vessel (inspected). The Coast Guard has recorded 5 inspections since 2016, most recently in February 2019, along with 5 deficiencies.

Records from 2016 to 2019. Most recent: inspection, 25 February 2019.

Built
1979
Last inspected
25 February 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 February 2019
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE8289
180534
Flag
UNITED STATES
Maury page id
psix-180534

Documentation record

Tonnage as PSIX records it12 - Simplified, Gross Ton
9 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

25 February 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6631523
19 December 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6326391
23 March 2017 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6099556
16 March 2016 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5834623
28 January 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5803570

Deficiency record · 5

Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 March 2017 Resolved
Repair/Replace fireboy visual/audible alarm
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2017
Resolved 24 March 2017
Resolution: Installed new alarm unit at operating station.
Lifesaving › Lifefloat › Float-free Link
Issued 23 March 2017 Resolved
Replace weak link for life float with weak link rated for 12 persons iaw 46CFR180.137(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2017
Resolved 24 March 2017
Resolution: Installed new weak link rated for appropriate number of passengers.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 March 2017 Resolved
Replace reflective tape on PFDs and life float iaw 46CFR185.604(h).
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 1 April 2017
Resolution: PFDs satisfactorily repaired.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 March 2017 Resolved
Separate the child PFDs from the adult PFDs iaw 46CFR180.78(A)(5)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 1 April 2017
Resolution: Adult and child PFDs satisfactorily separated.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 23 March 2017 Resolved
Retain current MIS reports aiw 46CFR16.260.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 1 April 2017
Resolution: Electronic versions of MIS reports were emailed to inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.