Records from 2023 to 2026. Most recent: inspection, 20 May 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT PONTOONS INC · TAVARES, FL, UNITED STATES · built 2025
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2026
Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Floating waterlight had no battery; vessel limited to daytime operation only until battery is provided.
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Battery was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2026
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The floating waterlight lanyard was tied around the body of the ring buoy; vessel limited to daytime operation only until corrosion resistant clip is provided.
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Corrosion resistant clip was provided.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 20 May 2026
Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include: 1) Closing each valve leading to an overboard discharge and removing the handle; 2) Padlocking each valve leading to an overboard discharge in the closed position; or 3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Sewage discharge valve was not secured from unintended use; MSD is not to be used until valve is secured.
Action required: 705 - Other - as specified
Resolved 18 June 2026
Resolution: Valve had been padlocked closed with chain.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 May 2026
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Only the first page of stability letter was visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026
Resolved 1 June 2026
Resolution: Full stability letter was posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2026
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Quantity of life jackets provided not marked on stowage containers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026
Resolved 1 June 2026
Resolution: Life jacket quantities posted.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 20 May 2026
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. EAP materials not displayed on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026
Resolved 1 June 2026
Resolution: EAP information sign posted.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 20 May 2026
Resolved
[Day]shapes shall be black. Anchor ball carried on board was white.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026
Resolved 18 June 2026
Resolution: Black anchor ball was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2026
Resolved
Arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Ring life buoy was not mounted securely to a bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026
Resolved 1 June 2026
Resolution: Ring buoy was securely mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2026
Resolved
A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Gasoline fuel filter bowls were of clear acrylic construction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026
Resolved 18 June 2026
Resolution: Metal fuel strainers were provided.