MAURY USCG vessel records
← All vessels

STENHEIM

STENHEIM is a 2002 tank ship. The Coast Guard has recorded 8 inspections since 2023, most recently in June 2026, along with 3 deficiencies and 1 operational control.

Records from 2023 to 2026. Most recent: inspection, 8 June 2026.

Built
2002
Last inspected
8 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9261114
CQ2445
1810291
Flag
PORTUGAL
Maury page id
psix-1810291

Documentation record

Tonnage as PSIX records it22578 - Displacement, Ton
5138 - Convention (Subpart B), Net Ton
11935 - Convention (Subpart B), Gross Ton
16614 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

8 June 2026 Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8393731
5 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8290474
11 December 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8282139
4 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8263964
27 October 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8256500
30 October 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8023068
1 April 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7888348
13 November 2023 PSC A · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7820910

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 October 2025 Resolved
ELECTRICAL EQUIPMENT, CABLES, AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH THE STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED 03 LIGHTS IN PIPE TRUNK WITH NO CERTIFICATION MARKINGS. CREW COULD NOT PROVIDE EVIDENCE OF RATING FOR INSTRUMENTATION IN HAZARDOUS LOCATIONS, PSCO OBSERVED EXPOSED WIRING ON PUMP AT THE TOP OF THE FILTER IN BALLWAST WATER TREATMENT ROOM. ADDITIONALLY PSCO OBSERVED APPROXIMATELY 50% OF LIGHT FIXTURES INSTALLED IN PIPE TRUNK WITH PLASTIC PACKING GLANDS THAT ARE NOT RATED FOR HAZARDOUS LOCATIONS. 74SOLAS(20) VII/10.1 IBC 10.1.4
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2025
Resolved 28 October 2025
Resolution: DEFICIENCY NUMBER (01) SHALL BE CLEARED PRIOR TO CARGO OPS. EXPOSED WIRING ON THE PUMP IN THE BWTS ROOM WAS PROPERLY REPAIRED AND SECURED.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 November 2023 Resolved
The high-level alarm system required under 15.9.6 shall be independent of the overflow-control system required by 15.19.7 and shall be independent of the equipment required by 13.1. PSCO observed the vessel not having a second independent overflow-control system. 74 SOLAS (20) VII 10.1 IBC CODE 15.19.5
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2023
Resolved 20 November 2023
Resolution: Vessel sent class report attesting to the rectification of the deficiency.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 13 November 2023 Resolved
The ship's identification number shall be permantly marked in a visible place either on the stern of the ship or on either side of the hull, amidships port and starboard, above the deepest asigned load line or either side of the superstructure, port and starboard or on the front of the superstructure. PSCO observed IMO number not marked in any required locations. 74 SOLAS (20) XI-1 3.4.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 20 November 2023
Resolution: Vessel sent class report attesting to the rectification of the deficiency.

Ownership record