MAURY USCG vessel records
← All vessels

SWEET PEA LEADER

SWEET PEA LEADER is a freight ship. The Coast Guard has recorded 5 inspections since 2023, most recently in November 2025, along with 3 deficiencies.

Records from 2023 to 2025. Most recent: inspection, 19 November 2025.

Built
Not recorded
Last inspected
19 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 November 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2023–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9960215
1811281
Flag
LIBERIA
Maury page id
psix-1811281

Documentation record

Tonnage as PSIX records it23294 - Convention (Subpart B), Net Ton
77644 - Convention (Subpart B), Gross Ton
18534 - Dead Weight, Metric Ton
40342 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

19 November 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8270828
1 February 2025 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8073134
1 February 2025 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8073892
7 September 2024 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7999417
19 November 2023 PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826620

Deficiency record · 3

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 February 2025 Resolved
All gearing and every shaft and coupling used for transmission of power to machinery essential for the propulsion and safety of the ship or for the safety of persons on board shall be so designed and constructed that they will withstand the maximum working stresses to which they may be subjected in all service conditions. Vessel reported a loss of propulsion caused by an air line becoming detached from a union joint on the main engine starting air pilot line. SOLAS (20) II-1/27.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 February 2025
Resolution: Vessel provided satisfactory class survey report attesting to repair of an air line union joint on the main engine. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2024 Resolved
The procedures and information shall include maintenance of electrical equipment that is installed in explosion hazardous spaces and areas. The insection and maintenance of electrical installations shall be performed in accordance with a recognized standard. Records for hazardous area electrical equipment maintenance are not being performed.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2024
Resolution: Received satisfactory objective evidence.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2024 Resolved
Where electrical equipment is installed in hazardous areas it shall be selected, installled and maintained in accordance with a recognized standard. Cable glands were not properly packed on bunker station ESD valve and TCS #1 low temperature sensor in HPP room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2024
Resolution: Cleared on the spot.

Ownership record