MAURY USCG vessel records Sign in
← All vessels

ENTERPRISE

ENTERPRISE is a 1980 offshore supply vessel. The Coast Guard has recorded 43 inspections since 1990, most recently in January 2026, along with 51 deficiencies and 1 operational control.

Records from 1990 to 2026. Most recent: inspection, 16 January 2026.

Built
1980
Last inspected
16 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW7635
181259
Flag
UNITED STATES
367121870
Maury page id
psix-181259

Inspections, by type

…with no type recorded2
Years with a record 26 calendar years (1990–2026)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 24.0 ft × 5.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS, INC. · HARVEY LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW7635MMSI 367121870 · active · compulsorily equipped · granted 6 May 2026, expires 29 July 2036
WCP7376MMSI not assigned · cancelled · compulsorily equipped · granted 24 January 1995, cancelled 19 April 2001
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 43

16 January 2026 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8289222
17 November 2025 Internal Structural Exam · Vessel Attendance · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8268785
5 June 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7921617
21 November 2022 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7592110
4 April 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7424019
12 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6441949
16 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6415714
28 March 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6182175
6 November 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5758253
15 April 2008 Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3184758
30 January 2008 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3138954
15 October 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3080239
13 June 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2679516
2 March 2005 Internal Structural Exam · Hull Examination · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2301900
26 May 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2078675
11 June 2003 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1815285
3 April 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1615015
15 September 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 55582
22 May 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065006
2 April 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447065
10 March 2000 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461252
24 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811517
1 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041797
12 July 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1100022
21 April 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397152
26 March 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469502
28 October 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182636
5 June 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443877
19 August 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357698
5 September 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184798
26 August 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190250
9 June 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403954
22 August 1994 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172401
17 March 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450833
26 March 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439365
8 June 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464443
30 March 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953798
28 June 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248758
17 June 1991 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937676
27 March 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922263
14 March 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922738
24 January 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899561
21 March 1990 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931598

Deficiency record · 51

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 January 2026 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation IAW the terms of its certificate of inspection. Port & Stbd ER hatches do not completely seal when secured and light is visible.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2026
Resolved 22 January 2026
Resolution: Adjusted dogs on port & stbd hatches, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 January 2026 Resolved
Vessel shall have adequate & up to date charts. Vessel did not have current charts for operating area on board.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2026
Resolved 22 January 2026
Resolution: Witnessed new charts for operating area.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 January 2026 Resolved
Vessel shall keep vessel log with training, drills, epirb tests, lifesaving equipment maintenance record, firefighting maintenance records, etc. Vessel did not have any drills, epirb tests, logs, checks, or maintenance filled out.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2026
Resolved 22 January 2026
Resolution: All logs were filled out.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 16 January 2026 Resolved
A durable placard must be posted next to all radiotelephone with emergency broadcast instructions and information specific to the vessel. Vessel did not have emergency broadcast procedures posted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 22 January 2026
Resolution: Emergency instructions posted in the wheel house.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 January 2026 Resolved
Placards containing instructions for donning and the use of life jackets must be posted in a conspicuous place. Placard missing from lower deck bunk room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 22 January 2026
Resolution: Placard posted for life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2026 Resolved
This part is intended to provide electrical installations and equipment that is safe from electrical shock of personnel. Exposed light fixture on bridge and exposed wiring behind the radio on the bridge allows for electrical shock.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 22 January 2026
Resolution: COver installed on th elight and exposed wires removed from behind VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 January 2026 Resolved
Each life float must be approved under 160.027: The current nameplate is illegible due to corrosion and retro tape is worn and inadequate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 22 January 2026
Resolution: Lifeloat refurbished with new dataplate.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 June 2024 Resolved
Vessel shall have up to date charts. Vessel did not have current charts onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2024
Resolution: Provided invoice for new charts.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 June 2024 Resolved
On a vessel at least 26 ft, a visual and audible alarm must be provided at the operating station to indicate high water level. Vessel had toggle switches that turned off the audible alarm in both rudder compartments and were turn off until found.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2024
Resolution: Provided picture with switch removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 June 2024 Resolved
All machinery shall be maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Vessel had moderately chaffed flexiable fuel line on the stbd generator from racor to prime mover. 46CFR182.05-1 (OLD-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 17 June 2024
Resolution: Provided picture of new hose with chaffing protection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 June 2024 Resolved
Vessel must carry eithera first-aid kit approved under 160.041 or kit with equivalent contents. Vessel had missing and/or expired items from the first-aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 17 June 2024
Resolution: Provided picture of new first aid kit.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 June 2024 Resolved
Vessel shall keep vessel log with training, drills, epirb, lifesaving equipment maintenance record, firefighting maintenance records, etc. Vessel's log did not have any drills or lifesaving records. Vessel going to new record keeping system.
Action required: 10 - Deficiency Rectified
Resolved 5 June 2024
Resolution: Educated master, crew and vessel rep. New system in place to record.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 March 2017 Resolved
Alcohol test strips were expired.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 March 2017
Resolution: Alcohol test strips replaced prior to completion of inspection
Navigation › Piloting/Steering › Compass Deviation Table
Issued 28 March 2017 Resolved
Compass deviation card faded
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 March 2017
Resolution: Operator had legible copy and placed on vessel
Communications › Radio Communications › EPIRB
Issued 6 November 2015 Resolved
The EPIRB registration was expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2015
Resolution: Vessel rep provided updated documentation.
Communications › Radio Communications › EPIRB
Issued 6 November 2015 Resolved
The EPIRB battery was expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2015
Resolution: Third party installed new battery and tested, all sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 November 2015 Resolved
The ventilation dampers on port and stbd. need gaskets and need to be labeled.
Due 15 November 2015
Resolved 12 November 2015
Resolution: Installed new gaskets and labeled, all sat.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 6 November 2015 Resolved
The anomometer was not onboard.
Action required: 705 - Other - as specified
Resolved 12 November 2015
Resolution: Company purchased new anomometer for the vessel, all sat.
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 November 2015 Resolved
The electric motor needs to be mounted in place.
Due 15 November 2015
Resolved 12 November 2015
Resolution: Installed mounting hardware, all sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 April 2008 Resolved
Rudder room bilge alarm doesn't work properly.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 October 2008
Resolution: Alarm fixed prior to completion of inspection and demonstrated satisfactory operation to inspector.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 15 April 2008 Resolved
Emergency Broadcast Placard missing.
Action required: 705 - Other - as specified
Resolved 9 October 2008
Resolution: A new copy was provided on the bridge.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 15 October 2007 Resolved
Renew cracked window on starboard bridge door.
Due 15 November 2007
Resolved 30 January 2008
Resolution: Window replaced.
Communications › Radio Communications › EPIRB
Issued 15 October 2007 Resolved
Renew hydrostatic release on EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2007
Resolution: Renewed Hydrostatic release.
Lifesaving › Lifefloat › Capacity
Issued 15 October 2007 Resolved
Label Life Float capacity on life float.
Due 15 November 2007
Resolved 30 January 2008
Resolution: Life Float capacity labeled.
Engineering › Lubricating Oil Service System › Gauge
Issued 15 October 2007 Resolved
Renew pressure gauge on bridge.
Due 15 November 2007
Resolved 15 October 2007
Resolution: Renewed pressure gauge.
Engineering › Bilge Water Management System › Pump
Issued 15 October 2007 Resolved
Mount Bilge pump properly.
Due 15 November 2007
Resolved 30 January 2008
Resolution: Bilge Pump mounted properly.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 October 2007 Resolved
Install guards on MDE's.
Due 15 November 2007
Resolved 16 October 2007
Resolution: Installed machinery guards on MDE''s.
Engineering › Fuel Oil Service System › Hose
Issued 15 October 2007 Resolved
Install piping to reduce flexible hose length to less than 30".
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2007
Resolution: Installed hard piping and reduced flexible fuel hose length to below 30".
Electrical › Electric Generation Source (service) › Generator
Issued 15 October 2007 Resolved
Repair exhaust leak on Port Generator.
Due 15 November 2007
Resolved 30 January 2008
Resolution: Exhaust leak repaired.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 October 2007 Resolved
Provide Lifesaving maintenance record.
Due 15 November 2007
Resolved 30 January 2008
Resolution: Life saving maintenance record provided.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 13 June 2006 Resolved
Provide radio operators license prior to sailing.
Action required: 705 - Other - as specified
Due 13 July 2006
Resolved 17 July 2006
Stability › Watertight Integrity
Issued 26 May 2004 Resolved
Repair port engine room door dogs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2004
Resolution: Dogs repaired.
Stability › Watertight Integrity
Issued 26 May 2004 Resolved
Repair both port & stbd R/R escape hatches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2004
Resolution: Hatches repaired.
Stability › Watertight Integrity
Issued 26 May 2004 Resolved
Service ball check vents as necessary
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2004
Resolution: Serviced.
Lifesaving › Buoyant Apparatus
Issued 11 June 2003 Resolved
Replace Lifefloat for a new one.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2003
Resolved 11 June 2003
Lifesaving
Issued 12 July 1999 Resolved
DEMONSTRATE COMLIANCE WITH THE EIGHTH COAST GUARD DISTRICT'S POLICY "RESCUEBOATS ON OFFSHORE SUPPLY VESSELS" TO THE SATISFATION OF THE ATTENDING COASTGUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Lifesaving
Issued 21 April 1999 Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH COAST GUARD DISTRICT'S POLICY "RESCUE BOAT REQUIREMENTS ON THE OFFSHORE SUPPLY VESSELS" DATED 12NOV98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Documentation
Issued 5 June 1997 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION. VESSEL IS NOT TO OPERATE UNTIL ONBOARD.
Condition: Unknown
Due 5 June 1997
Resolved 6 June 1997
Documentation
Issued 9 June 1995 Resolved
PROVIDE ON BOARD AN APPROVED OPERATING MANUAL.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Documentation
Issued 9 June 1995 Resolved
PROVIDE ON BOARD A CG ISSUED STABILITY LETTER.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Documentation
Issued 26 March 1993 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO COAST GUARD MSC FOR APPROVAL.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Electrical
Issued 26 March 1993 Resolved
INSTALL TILT ALARM ON BRIDGE.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Documentation
Issued 26 March 1993 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORT TO COAST GUARD MSC FOR APPROVAL.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Documentation
Issued 26 March 1993 Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER OR IF ISSUED BY ABS SUBMIT STABILITY LETTER TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Lifesaving
Issued 30 March 1992 Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED FIRE CONTROL/SAFETY PLAN AS PER NVIC 8-91.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Construction/Loadline
Issued 30 March 1992 Resolved
PROVE PROPER OPERATION OF BILGE ALARM IN PILOT HOUSE AS PER NVIC 8-91.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Documentation
Issued 21 March 1990 Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER OR IF ISSUED BY ABS SUBMIT ABS ISSUED STABILITY LETTER TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Documentation
Issued 21 March 1990 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Navigation
Issued 21 March 1990 Resolved
SWING VESSEL AND PROVIDE ON BOARD A DEVIATION TABLE.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Deck/Cargo
Issued 21 March 1990 Resolved
PROVIDE LOAD TEST OF CRANE IN ACCORDANCE WITH 46 CFR 107.258 AND 46 CFR 107.260. IF NOT WITNESSED BY ABS OR ICGB, THE TEST MUST BE WITNESSED IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.