Records from 2023 to 2026. Most recent: inspection, 5 June 2026.
Documentation record
Registered dimensions (L × B × D)46.5 ft × 15.0 ft × 4.8 ft
Registered tonnagegross 15 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRIX MARINE · PORT ANGELES, WA, UNITED STATES · built 2024
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portCHENEGA, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 23 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2026
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Prior to continuing commercial service the vessel shall troubleshoot the port inboard engine issue and complete sea trials to the satisfaction of the attending CG Marine Inspector. 46 CFR 176.840
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2026
Resolved 12 June 2026
Resolution: Sea trials were completed via bringing the vessel up to cruising speed and making a loop in the Port of Valdez. Additonally two mooring evolutions were observed. All 04 outboard engines including the newly replaced port inboard engine performed as designe
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2026
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the inspection of each portable fire extinguisher and fixed gas fire extinguishing system to check for excessive corrosion and general condition. Portable fire extinguishers did not have required annual inspection as per NFPA 10, and pre-engineered fixed fire extinguishing system for the gasoline tank space was not annually serviced. 46 CFR § 176.810(a)(1); (b)(1)(i); and (b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2026
Resolved 28 April 2026
Resolution: Received photographic evidence of fixed pre-engineered fire system and portable fire extinguisher servicing.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 April 2026
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry — six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel had only three red flares with the 160.021 approval. Others were approved under 160.066, which are only for recreational use. 46 CFR 180.68(a)
Action required: 10 - Deficiency Rectified
Resolved 23 April 2026
Resolution: Operator found additional flares shoreside that were not expired.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 April 2026
Resolved
Each vessel with more than one passenger deck and a vessel with overnight accommodations must have a public address system operable from the operating station. Vessel's internal public address system would not work and would mute the speaker immediately after talking through the system. 46 CFR 184.610(c)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 23 April 2026
Resolution: After troubleshooting, operator discovered how to properly use the public address system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2024
Resolved
Nonmetallic piping must not be used in gasoline or diesel fuel systems. Non-approved flexible plastic tubing is being used in lieu of approved copper piping for diesel cook-top. Replace with copper piping as per submitted plans prior to operating cook-top system. 46 CFR 182.720(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 April 2026
Resolution: Inspected replacement copper piping for the diesel cook top.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 August 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel’s stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Upper deck is incorrectly marked as allowing six persons when stability limits the upper deck to five persons. 46 CFR 185.602(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 12 September 2024
Resolution: Received photographic evidence showing upper deck correctly indicating 5 persons permitted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2024
Resolved
There must be one 40-B:C in the vicinity of the exit of a machinery space. The space containing the auxiliary generator does not have a 40-B:C in the vicinity of the exit of the space. 46 CFR 181.500(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 12 September 2024
Resolution: Received photographic evidence showing 40-B:C now mounted on the exterior door immediately outside of the generator space
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 August 2024
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radiobeacon (EPIRB). Vessel name is not marked on the EPIRB. 46 CFR 185.604(c)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 12 September 2024
Resolution: Received photographic evidence showing EPIRB with the name OMC / JACKPOT BAY.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 15 August 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff on diesel tank for heater outside of wheelhouse was not marked as noted above. 46 CFR 185.608
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 3 October 2024
Resolution: Received photographic evidence showing labeled fuel shut off valve for the heater exterior of the wheelhouse.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 August 2024
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vessel's inflatable buoyant apparatus' painter was not secured to the vessel's float free link. 46 CFR 180.130(a)(1)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 August 2024
Resolution: Survival craft hydrostatic release reinstalled correctly.