JACKPOT BAY is a 2024 passenger vessel (inspected). The Coast Guard has recorded 5 inspections since 2023, most recently in June 2026, along with 10 deficiencies.

Records from 2023 to 2026. Most recent: inspection, 5 June 2026.

Built
2024
Last inspected
5 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2026
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP7306
1813977
Flag
UNITED STATES
Maury page id
psix-1813977

Documentation record

Registered dimensions (L × B × D)46.5 ft × 15.0 ft × 4.8 ft
Registered tonnagegross 15 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRIX MARINE · PORT ANGELES, WA, UNITED STATES · built 2024
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portCHENEGA, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 23 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

5 June 2026 Examination of Repairs
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8401502
27 May 2026 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8382180
23 April 2026 COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8355752
15 August 2024 Initial Certification · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7967758
10 August 2023 Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7905210

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2026 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Prior to continuing commercial service the vessel shall troubleshoot the port inboard engine issue and complete sea trials to the satisfaction of the attending CG Marine Inspector. 46 CFR 176.840
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2026
Resolved 12 June 2026
Resolution: Sea trials were completed via bringing the vessel up to cruising speed and making a loop in the Port of Valdez. Additonally two mooring evolutions were observed. All 04 outboard engines including the newly replaced port inboard engine performed as designe
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2026 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the inspection of each portable fire extinguisher and fixed gas fire extinguishing system to check for excessive corrosion and general condition. Portable fire extinguishers did not have required annual inspection as per NFPA 10, and pre-engineered fixed fire extinguishing system for the gasoline tank space was not annually serviced. 46 CFR § 176.810(a)(1); (b)(1)(i); and (b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2026
Resolved 28 April 2026
Resolution: Received photographic evidence of fixed pre-engineered fire system and portable fire extinguisher servicing.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 April 2026 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry — six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel had only three red flares with the 160.021 approval. Others were approved under 160.066, which are only for recreational use. 46 CFR 180.68(a)
Action required: 10 - Deficiency Rectified
Resolved 23 April 2026
Resolution: Operator found additional flares shoreside that were not expired.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 April 2026 Resolved
Each vessel with more than one passenger deck and a vessel with overnight accommodations must have a public address system operable from the operating station. Vessel's internal public address system would not work and would mute the speaker immediately after talking through the system. 46 CFR 184.610(c)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 23 April 2026
Resolution: After troubleshooting, operator discovered how to properly use the public address system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2024 Resolved
Nonmetallic piping must not be used in gasoline or diesel fuel systems. Non-approved flexible plastic tubing is being used in lieu of approved copper piping for diesel cook-top. Replace with copper piping as per submitted plans prior to operating cook-top system. 46 CFR 182.720(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 April 2026
Resolution: Inspected replacement copper piping for the diesel cook top.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 August 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel’s stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Upper deck is incorrectly marked as allowing six persons when stability limits the upper deck to five persons. 46 CFR 185.602(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 12 September 2024
Resolution: Received photographic evidence showing upper deck correctly indicating 5 persons permitted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2024 Resolved
There must be one 40-B:C in the vicinity of the exit of a machinery space. The space containing the auxiliary generator does not have a 40-B:C in the vicinity of the exit of the space. 46 CFR 181.500(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 12 September 2024
Resolution: Received photographic evidence showing 40-B:C now mounted on the exterior door immediately outside of the generator space
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 August 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radiobeacon (EPIRB). Vessel name is not marked on the EPIRB. 46 CFR 185.604(c)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 12 September 2024
Resolution: Received photographic evidence showing EPIRB with the name OMC / JACKPOT BAY.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 15 August 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff on diesel tank for heater outside of wheelhouse was not marked as noted above. 46 CFR 185.608
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 3 October 2024
Resolution: Received photographic evidence showing labeled fuel shut off valve for the heater exterior of the wheelhouse.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 August 2024 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vessel's inflatable buoyant apparatus' painter was not secured to the vessel's float free link. 46 CFR 180.130(a)(1)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 August 2024
Resolution: Survival craft hydrostatic release reinstalled correctly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.