Records from 2024 to 2026. Most recent: inspection, 29 April 2026.
Inspection history · 7
29 April 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8346832
9 February 2026
Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8307886
8 April 2025
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8107969
8 July 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7952898
26 April 2024
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7901815
3 April 2024
Initial Certification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7888929
10 January 2024
Construction Oversight
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7847925
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 April 2026
Resolved
The loading mark must be painted in a contrasting color to the side shell paint. Vessel has loading marks painted the same color as the side shell paint. Re-paint to be contrasting color.
46 CFR 185.602(d)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
Resolution: Vessel painted loading mark with contrasting colors
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 29 April 2026
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have emergency or donning instructions posted.
46 CFR 185.510(a)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
Resolution: Emergency and donning instructions posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2026
Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck. Bracket for portable fire extinguishers aft of operating station were broken. Replace to the satisfaction of the marine inspector.
46 CFR 185.500(d)
16c
46 CFR 185.500(d)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
Resolution: Broken brakcets replaced in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2026
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Ring life buoy clip was corroded. Replace to the satisfaction of the marine inspector.
46 CFR 184.70 (d)(3)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 1 May 2026
Resolution: O/O changed clip to a corrosion resistant clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2026
Resolved
Each rescue boat and ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring life buoy was not fitted with reflective tape. Install to the satisfaction of the marine inspector.
46 CFR 185.604(i)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 1 May 2026
Resolution: O/O added reflective tape to life buoy.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 April 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number required on a vessel must not be fewer than the minimum req'd by Table 181.500(b). The installed portable extinguishers do not meet the above req'mt. The vsl must install: (1) 10-B:C, (1) 2-A, & (1) 40-B:C fire extinguisher prior to commercial operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 3 April 2024
Resolution: Received receipt for installation of proper portable fire extinguishers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024
Resolved
Remote fuel shutoff valves must be marked in clearly legible letters at least 1" high & indicate the direction of operation. The shutoff valves onboard the vsl are not labeled. The vsl must label the shutoff valves in accordance with the above req'mt prior to commercial operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 4 April 2024
Resolution: Received a receipt for installment of signs for the fuel shutoff valves.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 April 2024
Resolved
The master shall conduct sufficient drills to make sure that all crew members are familiar w/their duties during emergencies that include recovery of persons who have fallen overboard. The weather conditions precluded conducting a drill. The vsl must perform a man overboard drill prior to commercial operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 23 April 2024
Resolution: Vessel completed successful man overboard drill to the satisfaction of the attending marine inspector.