← All vessels
SWAN BISCAY
SWAN BISCAY is a tank ship. The Coast Guard has recorded 3 inspections in 2025, along with 3 deficiencies.
Records in 2025. Most recent: inspection, 15 September 2025.
- Built
- Not recorded
- Last inspected
- 15 September 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Inspection record
Last inspected
15 September 2025
Deficiencies
3 recorded · 0
without a recorded resolution
Operational controls
None recorded without a removal date
Years with a record
1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Identity
9466532
CQ2149
1814605
Flag
PORTUGAL
Maury page id
psix-1814605
Documentation record
Tonnage as PSIX records it5206 - Convention (Subpart B), Gross Ton
2212 - Convention (Subpart B), Net Ton
2212 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
15 September 2025
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8234963
20 August 2025
Deficiency Check · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8214019
18 March 2025
COC-CHEM & TVE Renew · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8094589
Deficiency record · 3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 August 2025
Resolved
74SOLAS (20) I/11 (a) The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons.
While the vessel was mooring at Vopak, the ship experienced a total loss of ship's power.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 August 2025
Resolved
70SOLAS(20)VII 110.1, IBC 10.1.2.1 Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO observed an improperly wierd connection for an ex fitting used to guage the liquid level of cargo for CT6S.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 20 August 2025
Resolved
46CFR 39.2013(b)(2)Activates an alarm when pressure sensing device measures a high pressure of not more than 90% of the lowest pressure relief value setting in the cargo tank venting system. PSCO observed inoperable pressure alarms in the vessel's CCR for CT3S, CT6S, and residual tanks also had inoperable liquid level alarms as well.