15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 March 2024
Resolved
The company and the ship shall comply with the requirements of the International Ship Management Code. For the purpose of this regulation the requirement of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external ISM audit report, satisfactory to the Coast Guard, must be submitted prior to clearance of this deficiency and departure.
74 SOLAS (20) IX/3.1
ISM Code Part A/10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 March 2024
Resolution: Received Flag Inspection Report and Class Report stated that all defs have been rectified. Conducted def check and cleared all outstanding defs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 March 2024
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO's observed an excess amount of oil beneath the deck plates in the oil purifier room and in the containment area around the main engine. Additionally, PSCO's observed an excess amount of oily-water mixture throughout the engine room bilge.
74 SOLAS (20) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 March 2024
Resolution: The crew cleaned oil accumulation in the auxiliary engine room, purifier room, and main engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 5 March 2024
Resolved
Surfaces with temperatures above 220oC which may be impinged as a result of a fuel system failure shall be properly insulated. PSCO's observed oil-soaked lagging and missing lagging from high temperature pipes throughout the engine room specifically in the oil-purifier room and in the vicinity of the main engine.
74 SOLAS (20) II-1/4.2.2.6.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 March 2024
Resolution: The crew replaced oil soaked and failing lagging.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 5 March 2024
Resolved
Oil filtering equipment referred to in this regulation shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. During the operational test, PSCO's observed a leak emanating from the oil filtering equipment rendering it inoperable. Leak has been present for 14 days.
MARPOL (22 cons.) Annex I/Reg. 14.6
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 March 2024
Resolution: The crew repaired the leak in the OWS pump.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 March 2024
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO's observed an extinguished emergency light in the vicinity of assembly station #2 on the port side.
74 SOLAS (20) III/11.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2024
Resolution: The crew replaced the extinguished emergency light.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 March 2024
Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. PSCO's observed more than 30 cases of bottled water in the corridor on deck A obstructing the escape route to assembly station #1 on the starboard side.
74 SOLAS (20) II-2/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2024
Resolution: The crew cleared the escape route of any obstacles.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2024
Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. PSCO's observed exposed electrical wiring in the engine room workshop and from a smoke detector located in the corridor leading to the steering gear compartment.
74 SOLAS (04) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2024
Resolution: The crew repaired the exposed electrical wiring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2024
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration. PSCO's observed a leakage in the main engine jacket cooling water line.
74 SOLAS (04) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2024
Resolution: The crew replaced the failed gasket material causing the leakage.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 March 2024
Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. PSCO's observed a broken pressure gauge on the steering gear rendering the gauge inoperable.
74 SOLAS (04) II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2024
Resolution: The crew replaced the failed gauge.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 5 March 2024
Resolved
Drills shall, as far as practicable, be conducted as if there were an actual emergency. The crew demonstrated a lack of competency during the fire drill when a fire party team member entered the affected area with a malfunctioning SCBA.
74 SOLAS (20) III/19.3.1
Action required: 10 - Deficiency Rectified
Resolved 5 March 2024
Resolution: Following the failed fire drill the malfunctioning SCBA was taken out of service and replaced. PSCO's had the crew test three additional SCBAs and the fire drill was conducted again with no issues.