SILVER RAY is a 2021 passenger vessel (inspected). The Coast Guard has recorded 3 inspections since 2024, most recently in December 2025, along with 3 deficiencies.
Records from 2024 to 2025. Most recent: inspection, 2 December 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it55051 - Regulatory (Subpart C or D), Gross Ton 19682 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 December 2025Resolved
In interior locations in passenger ships carrying more than 36 passengers, fire hoses shall be connected to the hydrants at all times. PSCO observed a fire hose located inside interior cabinet number P02.56 was disconnect.
74 SOLAS 20 II-2/10.3.1.1
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 December 2025
Resolution: Vessel crew connected the fire hose to hydrant.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2024Resolved
The following function al requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed Christmas ornaments being installed and affixed to be in the handrails in multiple decks in both the forward and aft passengers staircases along the escape route. 74SOLAS(20)II-2/13.1.2. Code 16AC.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2024
Resolved 16 December 2024
Resolution: Ornaments removed and stowed IAW Lloyd's Class Surveyor's statement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 December 2024Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the side or bottom. PSCO observed a plastic waste receptacle in housekeeping office in deck 3. 74SOLAS(20)/II-2/4.4.2 Code 10AC.
Action required: 10 - Deficiency Rectified
Due 15 December 2024
Resolved 15 December 2024
Resolution: Deficiency was rectified on the spot by removing from service the plastic waste receptacle.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.