MAURY USCG vessel records Sign in
← All vessels

PRINCE M

PRINCE M is a 2000 freight ship. The Coast Guard has recorded 15 inspections since 2001, most recently in May 2012, along with 4 deficiencies and 4 operational controls.

Records from 2001 to 2012. Most recent: inspection, 3 May 2012.

Built
2000
Last inspected
3 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9216808 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
—
Maury page id
psix-18156

Inspections, by type

…with no type recorded5
Years with a record 8 calendar years (2001–2012)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it52434 - Dead Weight, Ton
60772 - Displacement, Ton
30303 - Convention (Subpart B), Gross Ton
17734 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

3 May 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4301156
1 March 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3688119
31 January 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3403169
21 January 2009 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3394306
20 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3397322
16 November 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3363971
25 August 2006 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2759712
30 March 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2612837
24 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2609240
13 March 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2601421
14 June 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2390716
11 June 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2386758
28 July 2004 ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2147889
1 June 2004 Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2084216
2 August 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 292247

Deficiency record · 4

Engineering › Sea-water System (primary cooling) › Piping
Issued 21 January 2009 Resolved
PSCO noted a temporary patch on the discharge side of the #2 seawater cooling pump for the main cooling system. Make permanent repairs to satisfaction of Classification Society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 January 2009
Resolved 31 January 2009
Resolution: Received Classification report from RINA satisfying requirement.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 November 2006 Resolved
33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge 33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization (OSRO) or provide an OSRO contract for the remote Guam COTP zone
Due 29 December 2006
Resolved 15 January 2009
Resolution: NTVRP plan #04834 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Fire Fighting
Issued 2 August 2001 Resolved
INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL FIREFIGHTING INSTALLATIONS/EQUIPMENT MISSING. PROVIDE WITHIN 30 DAYS TO SATISFACTION OFCLASS. SOLAS 74(AMENDED) II-7/20.1
Condition: Unknown
Due 2 September 2001
Resolved 30 May 2004
Lifesaving
Issued 2 August 2001 Resolved
INSTRUCTIONS FOR ON BOARD MAINTENANCE OF LIFESAVING EQUIPMENT MISSING. PROVIDE WITHIN 30 DAYS TO SATISFACTION OF CLASS. SOLAS 74(AMENDED)III/19.1
Condition: Unknown
Due 2 September 2001
Resolved 30 May 2004

Ownership record