JUMBO is a 1983 towing vessel. The Coast Guard has recorded 5 inspections since 2024, most recently in May 2026, along with 8 deficiencies.

Records from 2024 to 2026. Most recent: inspection, 15 May 2026.

Built
1983
Last inspected
15 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1817734
Flag
UNITED STATES
Maury page id
psix-1817734

Inspections, by type

Years with a record 3 calendar years (2024–2026)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it59 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 5

15 May 2026 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8359406
22 May 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8126924
24 January 2025 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8069479
16 August 2024 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7985262
28 February 2024 Initial Certification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7871721

Deficiency record · 8

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 May 2026 Resolved
The tests required by this section must be recorded in accordance with part 140 of this Subchapter. Essential systems are required to be tested at least once every 3 months. Operation of remote emergency fuel shut off valve not recorded in vessel's towing vessel record.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2026
Resolved 22 May 2026
Resolution: Forms updated to include/capture quarterly testing of remote emergency fuel shut off valve.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2025 Resolved
The fixed fire pump is to be capable of being energized remotely from a safe place outside the engine room and at the pump. The pump on board vessel did not have capability to be energized from outside the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 2 June 2025
Resolution: Stop/start switch for fire pump installed on engine room bulkhead exterior (accessible from main deck).
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 22 May 2025 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Stern of vessel was not equipped with rails or equivalent protection at the vessel periphery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2025
Resolved 10 June 2025
Resolution: Stanchion with chains installed along the perimeter of the vessel's stern.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2025 Resolved
Vessel equipped with a fixed fire extinguishing system that did not satisfy requirements in 46 CFR 95.16 - "(a) Simple, complete operating instructions must be conspicuously located at or near any release station and in the extinguishing agent cylinder storage room. (b) On a system in which extinguishing agent cylinders are stored outside the protected space, operating instructions must also: (1) Include a schematic diagram of the system; and (2) Describe alternate methods of discharging the extinguishing agent into protected spaces should the manual releases or stop valve controls fail to operate." In the storage room instructions and system schematic were not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2025
Resolved 28 May 2025
Resolution: Schematic diagram developed and posted on board vessel.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 May 2025 Resolved
Essential systems required to be tested at least every 3 months. There was no record showing remote operation of emergency fuel shut off, corrected by end of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2025
Resolved 22 May 2025
Resolution: Valve exercised remotely and documented in vessels TVR.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2025 Resolved
Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”; Container not marked with "DISTRESS SIGNALS".
Action required: 10 - Deficiency Rectified
Due 22 May 2025
Resolved 22 May 2025
Resolution: Box properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2025 Resolved
Each lifejacket must be marked in block capital letters with the name of the vessel. Lifejackts not marked with vessel's name.
Action required: 10 - Deficiency Rectified
Due 22 May 2025
Resolved 22 May 2025
Resolution: PFDs properly marked with vessel's name.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 May 2025 Resolved
Fire control panels are required to include Labels for all switches and indicator lights, identifying their functions. System zone indicator lights, designed to cover 4 seperate zones, were not labeled to show the spaces associated with each zone.
Action required: 10 - Deficiency Rectified
Due 22 May 2025
Resolved 22 May 2025
Resolution: Zones labeled.