MAURY USCG vessel records
← All vessels

BV 1123

BV 1123 is a 2024 passenger vessel (inspected). The Coast Guard has recorded 4 inspections since 2023, most recently in July 2026, along with 2 deficiencies.

Records from 2023 to 2026. Most recent: inspection, 16 July 2026.

Built
2024
Last inspected
16 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 July 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP5434
1818879
Flag
UNITED STATES
Maury page id
psix-1818879

Documentation record

Registered dimensions (L × B × D)47.0 ft × 12.0 ft × 3.4 ft
Registered tonnagegross 16 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAZORHEAD ALUMINUM BOATS INC · NEW IBERIA, LA, UNITED STATES · built 2024
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

16 July 2026 Vessel Attendance · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8439798
3 June 2025 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8151315
10 June 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7931865
15 September 2023 Administrative Inspection · Simplified Stability Test · COI Inspection · Construction Oversight
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7858123

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 24 June 2025 Resolved
Each unpressurized fuel tank must be fitted with a vent pipe connected to the highest point of the tank. Port side fuel tank vent has a pin-hole leak at the 90 degree bend before the deck weld. Leak has been temporarily repaired with Belzona to prevent vapors from accumulating in the enclosed space. A permanent repair shall be completed prior to next annual inspection dated 04/18/2026.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 April 2026
Resolved 16 July 2026
Resolution: Inspected permanent repair of pin hole leak in fuel tank leak that was identified during last years annual inspection (A# 8151315) . MI allowed a temporary repair using splash zone epoxy. Cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must:(2) Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Pre-engineered system does not have remote activation capabilities from outside the space. Install a remote activation device outside the space, as per the manufacturer's guidelines applicable to the Fireboy model extinguishing system.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 3 September 2024
Resolution: Pre-engineered system installed IAW CFR and MFRSPEC.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.