Records from 2001 to 2025. Most recent: inspection, 5 December 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
5 December 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8277979
16 October 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8253886
8 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8060155
21 October 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8022295
6 August 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7975176
8 November 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7822078
6 October 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7804492
13 September 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7793815
30 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7629314
27 June 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7488785
16 June 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7229199
3 May 2021
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7183415
29 June 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7024040
27 January 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6896856
14 January 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6889362
24 June 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6723639
9 July 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6475688
24 July 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6222759
31 January 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6080428
2 May 2016
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5835984
5 May 2014
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4852405
8 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4109092
10 January 2011
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3924213
30 March 2010
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3705547
21 April 2009
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3456886
3 February 2009
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3411796
26 March 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3172831
16 May 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2933848
15 February 2007
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2872988
4 April 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2597133
5 April 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2329606
8 February 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2288438
8 April 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2113547
3 April 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1768077
6 February 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1749267
4 April 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1633700
25 February 2002
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1488806
1 May 2001
Inclining Experiment · Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1384843
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 October 2025
Resolved
CG001 - Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel was due for annual inspection no later than August 3, 2025.
46 CFR 176.500(B)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2025
Resolution: Vessel has been placed in "lay-up" status
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 October 2024
Resolved
11127 - Each buoyant apparatus must have a life line securely attached around the outside, festooned in bights no longer than 1 m (3 ft.), with a seine float in each bight, unless the line is of an inherently buoyant material and absorbs little or no water. The life line must be at least 10 mm (3/8 in.) diameter and have a breaking strength of at least 5400 N (1215 lb.). The life line around the life float was deteriorated and needs to be replaced.
46 CFR 180.200(a)(2)
46 CFR 160.027
46 CFR 160.010-4(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 8 January 2025
Resolution: Vessel owner requested to operate in warm water months only removing the requirement for a life float from the COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 August 2024
Resolved
CG001 - Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. The vessel's annual inspection was due to be completed no later than 03AUG2024.
46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2024
Resolution: An annual inspection was completed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 November 2023
Resolved
46 CFR 4.06-15 - The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a SMI. Vessels alcohol test strips were expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2023
Resolved 9 November 2023
Resolution: Owner put new alcohol strips onboard vessel to the satisfaction of the CG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2023
Resolved
46 CFR 183.200(a) - Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions. Vessel had (02) grounding wires that were disconnected due to wastage in the steering compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2023
Resolved 9 November 2023
Resolution: Owner reconnected grounding wires to the satisfaction of the CG Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2023
Resolved
46 CFR 176.500(b)(1) - Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Your vessel was due to have completed an annual inspection by 03 August 2023. You may not carry passengers until an annual inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Vessel had its annual exam for 2023.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021
Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. Flame shield bowls for fuel filters are fitted with drain valves without caps or plugs to prevent fuel leakage.
46 CFR 182.458(b)(9)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2021
Resolved 16 June 2021
Resolution: Confirmed via emailed pictures the removal petcock valves and installation of plugs on racor fuel filter flame shield bowls.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 May 2021
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by Federal Communications Commission, as set for the in 47 CFR part 80. Vessel's FCC Safety Radiotelephony Certificate expired 14APR2021.
46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2021
Resolved 26 May 2021
Resolution: FCC Safety Radiotelephony Certificate received, issued 26May2021 expires 26May2026.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 May 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date tide tables and current tables. Extracts for the areas to be transited may be provided instead of the complete publication. Tide and current tables last updated in 2019.
46 CFR 184.420(a)(3)-(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2021
Resolved 16 June 2021
Resolution: Confirmed adequate tide/current tables.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 May 2021
Resolved
Abandon ship, man overboard, and fire drills and training shall be conducted at least every 3 months and documented for review by USCG. Entries shall include date of the drill/training, and description of the drill scenario and training topics. Master stated they conduct drills, but does not record or document them.
46 CFR 185.520(f)
46 CFR 185.524(d)
Action required: 10 - Deficiency Rectified
Due 3 May 2021
Resolved 3 May 2021
Resolution: Conducted drills and observed Master recording drill in onboard records.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 3 May 2021
Resolved
The master of a vessel shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Vessel master stated they do not communicate or document their passenger counts prior to departing on voyages.
46 CFR 185.504
Action required: 10 - Deficiency Rectified
Due 3 May 2021
Resolved 3 May 2021
Resolution: Vessel master committed to filing passenger counts with Fisherman's Seafood Restaurant, as listed in Special Notes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2021
Resolved
Each life jacket kept in a stowage container must be readily available. Life jackets in aft stowage container were buried under mooring lines and electrical shore connection wires.
46 CFR 180.78(a)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 May 2021
Resolved 3 May 2021
Resolution: Items obstructing lifejackets removed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2016
Resolved
Attach life ring buoy light to life ring and properly mount. Vessel is restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 4 May 2016
Resolution: Received picture via email showing the waterlight properly attached to the lifering and properly mounted.
Engineering › Bilge Water Management System › Valve
Issued 5 May 2014
Resolved
All four through hull valves in way of electric bilge pumps are frozen in the open position. Repair/replace and prove proper operation to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 12 May 2014
Resolution: Received email pictures of valves being exercised.
Lifesaving › Hand Flares › Expired
Issued 21 April 2009
Resolved
Owner did not meet the requirement of 06 red, hand-held flares because of 03 expired flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2009
Resolution: Owner purchased 03 new VDS and placed in service.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 3 February 2009
Resolved
During the inspection it was noticed that the vessel has two seperate FM-200 pre-engineed gas fire supression systems. Each bottle was independently rated at 150 cubic feet, the engine space volume measued at 351.525 cubic feet. Issued a requirement for the vessel to install one bottle capable of covering the entire engine space when activated.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 1 April 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 April 2006
Resolved
Water light for ring buoy was inop. Vessel can not carry passengers between sunset and sunrise.
Due 20 April 2006
Resolved 7 April 2006
Resolution: Replaced battery in water light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2006
Resolved
Provide new first aid kit due to material condition of current kit and expiration of items.
Due 20 April 2006
Resolved 7 April 2006
Resolution: Replaced first aid kit.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 April 2006
Resolved
Generator could not be started due to dead battery and unable to test fixed fire system operation. No passengers may be carried while generator is being used until satisfactory test of fire system.
Due 20 April 2006
Resolved 4 April 2006
Resolution: Battery charged, started generator and conducted satisfactory test of fixed fire system.
Documentation › Certificates/Documents › FCC SSL
Issued 4 April 2006
Resolved
Provide proof of valid FCC Safety Certificate.
Due 20 April 2006
Resolved 9 May 2006
Resolution: New FCC Safety Certificate.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 April 2006
Resolved
Provide proof of current drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2006
Resolved 4 April 2006
Resolution: Vessel rep had prrof of enrollment faxed to vessel pror to inspector departure.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 April 2005
Resolved
Service all portable and fixed fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2005
Resolved 8 April 2005
Lifesaving › Hand Flares › Expired
Issued 5 April 2005
Resolved
Provide 6 handheld flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2005
Resolved 8 April 2005
Documentation › Logs/Records › Drug Test Records
Issued 5 April 2005
Resolved
Provide proof of enrollment in drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2005
Resolved 11 April 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2005
Resolved
Provide 18 foot lanyard for floating electric waterlight on life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2005
Resolved 8 April 2005
Lifesaving › Buoyant Apparatus › General
Issued 8 April 2004
Resolved
Prior to carrying passengers, stencil vesel name on the life float paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2004
Lifesaving › Visual Distress Signals (General) › Condition
Issued 8 April 2004
Resolved
Prior to carrying passenger at night, replace the waterlight on the life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 April 2004
Resolved
Stencil location of the 'emergency fuel shutoff' valve.
Due 20 April 2004
Resolved 1 July 2004
Stability › Watertight Integrity
Issued 6 February 2003
Resolved
Prior to refloating vessel: Reseal hatch on collision bulkhead.
Due 6 March 2003
Resolved 3 April 2003
Resolution: HATCH RESEALED.
Deck/Cargo › Ballast
Issued 6 February 2003
Resolved
Secure ballast ingots on port side generator space
Due 6 March 2003
Resolved 3 April 2003
Resolution: BALLAST SECURED WITH STEEL BANDING.
Deck/Cargo › Ballast
Issued 6 February 2003
Resolved
Provide weight of ballast ingots to BALMS
Due 6 March 2003
Resolved 14 February 2003
Resolution: 24.5# each
Stability › Watertight Integrity
Issued 6 February 2003
Resolved
Seal all watertight bulkhead penetrations
Due 6 March 2003
Resolved 3 April 2003
Resolution: ALL PENETRATIONS SEALED.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 February 2003
Resolved
Repair crack in port MDE exhaust LEGACY COMPONENT DESC: Piping (exhaust)
Due 6 March 2003
Resolved 3 April 2003
Resolution: FIBERGLASS REPAIR MADE.
Construction/Loadline › Penetrations
Issued 6 February 2003
Resolved
Reconnect bonding strap on washdown pump intake valve
Due 6 March 2003
Resolved 14 February 2003
Construction/Loadline › Penetrations
Issued 6 February 2003
Resolved
Double-clamp all thru-hull fittings
Due 6 March 2003
Resolved 14 February 2003
Pollution Prevention/Response › Prevention Equipment
Issued 6 February 2003
Resolved
Lock handle on three-way valve and remove valve handle on thru-hull for holding tank ovbd discharge LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 6 March 2003
Resolved 3 April 2003
Resolution: HANDLE TO OVERBOARD DISCHARGE REMOVED.