Inspection history · 12
11 June 2026
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8398929
10 May 2026
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8370429
28 April 2026
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8357019
1 December 2025
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8276606
13 November 2025
Administrative Inspection · Vessel Attendance
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8267779
29 September 2025
Drydock Exam · Internal Structural Exam · Vessel Attendance
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8243796
23 August 2025
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8216438
3 July 2025
Drydock Extension
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8176314
9 June 2025
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8154943
31 October 2024
Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8027483
19 June 2024
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7938456
14 May 2024
Reflagging & Initial Certification · Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7913292
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 10 May 2026
Resolved
Vessels described in Table 136.250 of this section that operate on the Great Lakes or outside the Boundary Lines, as set forth in 46 CFR part 7, are subject to load line requirements in subchapter E of this chapter in the following circumstances: (a) Is on an international voyage— (1) Seventy nine (79) feet (24 meters) or more in length and built on or after July 21, 1968; or (b) Is on a domestic voyage— (1) Seventy nine (79) feet (24 meters) or more in length and built on or after January 1, 1986. Vessel's short term Load Line Certificate expired, 10MAY2026. Until vessel has a valid Load Line Certificate, vessel is restricted from operating beyond the boundary line as defined by 46 CFR 7.5(c), entrance to Apra Harbor, Guam.
46 CFR 136.250 - 705 c (prior to operating beyond boundary)
Action required: 705 - Other - as specified
Resolved 26 June 2026
Resolution: Amended COI issued. Vessel's route changed to Lake, Bays and Sound. Vessel not allowed to transit outside of Apra Harbor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 August 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation;(2) Be suitable for route and service.
Vessel experienced loss of propulsion and control of azipod pitch while outbound from Apra Harbor Guam on voyage to Saipan, 23Aug25. Upon inspection of the air systems for both engines and azipods, crew and attending Marine Inspector, identified air leakage in the control and start air piping. Compressors, air receivers, and associated piping are unable to maintain adequate pressure to provide control to azipods while underway. Determine source, repair leaks, and perform satisfactory sea trials to prove proper operation of system as designed.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2025
Resolved 24 August 2025
Resolution: Repairs made to gaskets, control air reciever regulators and reducer. Tested system u/w for 1hr, system holding pressure at 2.4 to 2.7MPa with compressor topping up as designed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 June 2025
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Illuminated magnetic compass. The compass must be readable from each operating station. The magnetic compass was unable to be read from the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2025
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 June 2025
Resolved
An installation or multiple installations of VHF-FM radios as prescribed by part 26 of this chapter and 47 CFR part 80, to maintain a continuous listening watch on the designated calling channel, VHF-FM Channel 13. VHF radio was not supplied with emergency 24VDC power and unable to maintain continuous listening with a loss of ships power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2025
Resolved
Towing machinery used to connect the towing vessel to the tow must be suitable for its intended service. Aft tow winch has a major hydraulic leak causing the winch to be unservicable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 20 June 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2025
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. This includes machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools, and safety equipment. The focsle railing is wasted and needs to be repaired or replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 October 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel was unable to maintain engine RPM's or engage shafts while underway. Perform underway operational test to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 June 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide a safe operation of the towing vessel. The vessel was singled up on one generator and lost power due to low fuel distribution to the generator. Clean all fuel systems and complete an operational test of the generator in the presence of the attending MI.
46 CFR 143.205
Action required: 705 - Other - as specified
Due 28 August 2024
Resolved 28 August 2024
Resolution: The operator cleaned all fuel systems and the generator was tested in the presence of the MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 19 June 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 25 June 2024
Resolution: The vessel provided a valid load line issued by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Demonstrate proper operation of the main engines for its intended service and route to the satisfaction of the attending class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 May 2024
Resolved
Essential systems or equipment must be regularly tested
and examined. Tests and examinations must verify that the system or equipment functions as designed. Demonstrate proper operations of the steering system to the satisfaction of the attending class surveyor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Unapproved generator installed on the aft 01 deck feeding power through the vessels shore tie needs to be electrically isolated from the vessels electrical system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2024
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 30 May 2024
Resolved
Essential systems or equipment must be regularly tested
and examined. Tests and examinations must verify that the system or equipment functions as designed. Prove proper operation of the vessels potable water and sanitation systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2024
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 May 2024
Resolved
The illuminated magnetic compass or an illuminated swing-meter must be readable from each operating station. Provide current deviation table for the magnetic compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 May 2024
Resolved
Each towing vessel must carry the survival craft specified in Table 141.305 of this section, as appropriate for the towing vessel, in an aggregate capacity to accommodate the total number of individuals onboard. Install CG approved life raft and float free arrangment to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 13 August 2024
Resolution: This vessel is considered an excepted vessel and operates in harbor assist operations.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 May 2024
Resolved
Install, or prove compliance of a fire detection system that meets the approval standards and certification requirements of 46 CFR 330 to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 13 August 2024
Resolution: This vessel is considered an excepted vessel and operates as a harbor assist vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 May 2024
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. External aft ladder railing is missing mounting hardware.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 13 August 2024
Resolution: The crew replaced the hardware and placed galvanic isolaters between the hardware and railing metal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2024
Resolved
Each cable and wire on a towing vessel must be installed to meet the following requirements:Each cable and wire must be protected by metal coverings or other suitable means, if in areas subject to mechanical abuse. Engine room ventilation remote motor controlers on the 01 aft deck is wasted and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 13 August 2024
Resolution: The ventilation remote motor control was renewed. The crew tested the motor controller with no defs noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 May 2024
Resolved
The following systems must be equipped with gauges at the machinery location. The port side and stbd side generator’s jacket water temperature gauge is not reading actual temperature.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 28 August 2024
Resolution: The operator purchased new OEM temp gauges and placed them into service. The temp gauges operate as designed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 May 2024
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. The emergency lights in the galley, wash room, crew berthing is not working. In addition, steering space emergency lighting does not provide sufficient lighting for safe egress in an event of an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 13 August 2024
Resolution: All emergency lighting was replaced. The crew tested the e-lighting with the MI onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Replace all cracked light fixture covers in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 13 August 2024
Resolution: All fractured light fixtures were replaced.