Records from 2001 to 2005. Most recent: inspection, 10 March 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
10 March 2005
Random ISPS/MTSA/PSC · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2306931
6 February 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2287306
13 August 2004
ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2164806
2 July 2004
ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2120441
28 February 2004
Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2015421
15 February 2004
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2006801
30 January 2004
Annual Inspection · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1997230
28 February 2003
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1750626
3 February 2003
Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1738698
1 February 2003
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1738221
1 February 2003
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1738378
2 August 2002
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1655173
17 January 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1479380
21 November 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 295618
7 November 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 295241
16 March 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 288073
31 January 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 286541
18 January 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 286244
3 January 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 285721
Lifesaving › Lifeboat › Safety Belt
Issued 6 February 2005
Resolved
Safety belts found to be in unsatisfactory condition. All safety belts in both port and starboard lifeboats must be repaired/replaced prior to next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Completed.
Construction/Loadline › Structures › Door
Issued 6 February 2005
Resolved
Gasket lining on galley door found to be loose or torn in places. Repair / replace gasket lining on galley door prior to next US port.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Completed.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 6 February 2005
Resolved
Step on starboard ladder of the life raft deck is loose / broken. Replace lowest step on starboard ladder of the life raft deck prior to next US port.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Completed.
Lifesaving › Inflatable Liferafts
Issued 30 January 2004
Resolved
1. Provide servicing certificate for life rafts prior to arrival in to next United States port including Saipan.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2004
Resolution: Received servicing certificate for liferafts from Master. Master advised the certificates were faxed to MSO Guam upon servicing of liferafts 2/9/2004.
Accommodation/Occupational Safety › Ventilation
Issued 30 January 2004
Resolved
2. Replace vent screen in engine room on the lower level starboard side.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2004
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 30 January 2004
Resolved
3. Replace missing power switch cover on number two gas diesel engine indicator panel. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Ventilation
Issued 1 February 2003
Resolved
Galley vents frozen and heavily contaminated with grease creating increased risk of fire.
Due 8 February 2003
Resolved 28 February 2003
Construction/Loadline
Issued 1 February 2003
Resolved
Vents located on the port side of the stack require permanent repair. Temporary repair of large holes in piping made at request of USCG on 01 Feb 03.
Due 1 March 2003
Resolved 28 February 2003
Lifesaving › Launching Appliances
Issued 1 February 2003
Resolved
Port lifeboat lowering cable that allows crew to lower lifeboat from the lifeboat stern failed during the boat drill. Permanent repair required not later than 01 March 2003.
Due 1 March 2003
Resolved 1 February 2003
Engineering
Issued 1 February 2003
Resolved
Fire pump, MDE salt water cooling pump, auxiliary cooling water pump, number 2 S/W cooling reefer pump have wasted packing glands resulting in excessive leakage. Permanent repair/renewal required not later than 01 April 2003.
Due 1 April 2003
Resolved 28 February 2003
Engineering
Issued 1 February 2003
Resolved
No. 2 salt water cooling pump for the reefer has inoperable suction and discharge gauges. Permanent repair/replacement of the gauges required not later than 01 April 2003.
Due 1 April 2003
Resolved 28 February 2003
Fire Fighting › Firemans Outfit
Issued 1 February 2003
Resolved
Firemans outfit deteriorated, significantly raising risk of injury/casualty during an emergency. Replacement required to the satisfaction of the flag state and USCG not later than 08 Feb 2003.
Due 8 February 2003
Resolved 28 February 2003
Lifesaving
Issued 7 November 2001
Resolved
Engineroom bilge, particularly in way of the oily water seperator, contaminated with oily residues increasing the risk of unanticipated fire. Vsl shall clean and properly dispose of residues to remove unnecessary firehazard. SOLAS 74/78 I/11.
Condition: Unknown
Due 25 November 2001
Resolved 25 November 2001
Construction/Loadline
Issued 7 November 2001
Resolved
Cement patch on compressor room deck gives rise to concerns about the structural integrity of the underlying steel deck. NLT next SOLAS Safety Construction Annual Survey (ooa Spring 2002) the certificate issuing authority shall examine the vsl structure iwo of the patch.
Condition: Unknown
Due 1 March 2002
Resolved 17 January 2002
Resolution: Class determined that cement patch was adequate.
Documentation
Issued 7 November 2001
Resolved
Vsl failed to provide reasonable explaination as to its discharge of plastics, having records for only 0.4 cubic meter of plastics in a 60 day period. Vsl required to have class society review its waste management plan& procedures to ensure compliance with MARPOL 73/78 Annex V.
Condition: Unknown
Due 7 December 2001
Resolved 17 January 2002
Resolution: Cleared by GUAMS.
Fire Fighting
Issued 7 November 2001
Resolved
Self closing fire doors throughout the vsl need adjustment to properly close. SOLAS 74/78 amended II-2/47.
Condition: Unknown
Due 7 December 2001
Resolved 17 January 2002
Resolution: All fire doors closed properly. Cleard by GUAMS.
Electrical
Issued 31 January 2001
Resolved
Replace all damaged electrical wiring and wiring supports directly above_x001C_ the cascade tanks in the engine room at the nexst drydock. SOLAS 74 AM II-1/45.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Lifesaving
Issued 31 January 2001
Resolved
Have class society evaluate condition of sheaves on the port and stbd lifeboat davits and complete all necessary repairs. Provide copy of class report to USCG.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001