MAURY USCG vessel records Sign in
← All vessels

OCEAN CREDIT

OCEAN CREDIT is a 1985 freight ship. The Coast Guard has recorded 19 inspections since 2001, most recently in March 2005, along with 18 deficiencies.

Records from 2001 to 2005. Most recent: inspection, 10 March 2005.

Built
1985
Last inspected
10 March 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8509404 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-18280

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (2001–2005)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1898 - Regulatory (Subpart C or D), Net Ton
4977 - Dead Weight, Ton
4181 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

10 March 2005 Random ISPS/MTSA/PSC · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2306931
6 February 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2287306
13 August 2004 ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2164806
2 July 2004 ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2120441
28 February 2004 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2015421
15 February 2004 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2006801
30 January 2004 Annual Inspection · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1997230
28 February 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1750626
3 February 2003 Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1738698
1 February 2003 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1738221
1 February 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1738378
2 August 2002 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1655173
17 January 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1479380
21 November 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 295618
7 November 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 295241
16 March 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 288073
31 January 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 286541
18 January 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 286244
3 January 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 285721

Deficiency record · 18

Lifesaving › Lifeboat › Safety Belt
Issued 6 February 2005 Resolved
Safety belts found to be in unsatisfactory condition. All safety belts in both port and starboard lifeboats must be repaired/replaced prior to next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Completed.
Construction/Loadline › Structures › Door
Issued 6 February 2005 Resolved
Gasket lining on galley door found to be loose or torn in places. Repair / replace gasket lining on galley door prior to next US port.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Completed.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 6 February 2005 Resolved
Step on starboard ladder of the life raft deck is loose / broken. Replace lowest step on starboard ladder of the life raft deck prior to next US port.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Completed.
Lifesaving › Inflatable Liferafts
Issued 30 January 2004 Resolved
1. Provide servicing certificate for life rafts prior to arrival in to next United States port including Saipan.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2004
Resolution: Received servicing certificate for liferafts from Master. Master advised the certificates were faxed to MSO Guam upon servicing of liferafts 2/9/2004.
Accommodation/Occupational Safety › Ventilation
Issued 30 January 2004 Resolved
2. Replace vent screen in engine room on the lower level starboard side.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2004
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 30 January 2004 Resolved
3. Replace missing power switch cover on number two gas diesel engine indicator panel. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Ventilation
Issued 1 February 2003 Resolved
Galley vents frozen and heavily contaminated with grease creating increased risk of fire.
Due 8 February 2003
Resolved 28 February 2003
Construction/Loadline
Issued 1 February 2003 Resolved
Vents located on the port side of the stack require permanent repair. Temporary repair of large holes in piping made at request of USCG on 01 Feb 03.
Due 1 March 2003
Resolved 28 February 2003
Lifesaving › Launching Appliances
Issued 1 February 2003 Resolved
Port lifeboat lowering cable that allows crew to lower lifeboat from the lifeboat stern failed during the boat drill. Permanent repair required not later than 01 March 2003.
Due 1 March 2003
Resolved 1 February 2003
Engineering
Issued 1 February 2003 Resolved
Fire pump, MDE salt water cooling pump, auxiliary cooling water pump, number 2 S/W cooling reefer pump have wasted packing glands resulting in excessive leakage. Permanent repair/renewal required not later than 01 April 2003.
Due 1 April 2003
Resolved 28 February 2003
Engineering
Issued 1 February 2003 Resolved
No. 2 salt water cooling pump for the reefer has inoperable suction and discharge gauges. Permanent repair/replacement of the gauges required not later than 01 April 2003.
Due 1 April 2003
Resolved 28 February 2003
Fire Fighting › Firemans Outfit
Issued 1 February 2003 Resolved
Firemans outfit deteriorated, significantly raising risk of injury/casualty during an emergency. Replacement required to the satisfaction of the flag state and USCG not later than 08 Feb 2003.
Due 8 February 2003
Resolved 28 February 2003
Lifesaving
Issued 7 November 2001 Resolved
Engineroom bilge, particularly in way of the oily water seperator, contaminated with oily residues increasing the risk of unanticipated fire. Vsl shall clean and properly dispose of residues to remove unnecessary firehazard. SOLAS 74/78 I/11.
Condition: Unknown
Due 25 November 2001
Resolved 25 November 2001
Construction/Loadline
Issued 7 November 2001 Resolved
Cement patch on compressor room deck gives rise to concerns about the structural integrity of the underlying steel deck. NLT next SOLAS Safety Construction Annual Survey (ooa Spring 2002) the certificate issuing authority shall examine the vsl structure iwo of the patch.
Condition: Unknown
Due 1 March 2002
Resolved 17 January 2002
Resolution: Class determined that cement patch was adequate.
Documentation
Issued 7 November 2001 Resolved
Vsl failed to provide reasonable explaination as to its discharge of plastics, having records for only 0.4 cubic meter of plastics in a 60 day period. Vsl required to have class society review its waste management plan& procedures to ensure compliance with MARPOL 73/78 Annex V.
Condition: Unknown
Due 7 December 2001
Resolved 17 January 2002
Resolution: Cleared by GUAMS.
Fire Fighting
Issued 7 November 2001 Resolved
Self closing fire doors throughout the vsl need adjustment to properly close. SOLAS 74/78 amended II-2/47.
Condition: Unknown
Due 7 December 2001
Resolved 17 January 2002
Resolution: All fire doors closed properly. Cleard by GUAMS.
Electrical
Issued 31 January 2001 Resolved
Replace all damaged electrical wiring and wiring supports directly above_x001C_ the cascade tanks in the engine room at the nexst drydock. SOLAS 74 AM II-1/45.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Lifesaving
Issued 31 January 2001 Resolved
Have class society evaluate condition of sheaves on the port and stbd lifeboat davits and complete all necessary repairs. Provide copy of class report to USCG.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.