Records from 2024 to 2025. Most recent: inspection, 11 March 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 November 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a jacket water cooling leak on the main engine.
74 SOLAS (20) II-1 (a)
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 March 2025
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 13 November 2024
Resolved
Colf fresh water and hot fresh water available in all wash spaces. PSCO observed that all wash basin had a single faucet without control to hot and cold water supplied.
ILO 147 Reg. 21(c), pg37
46 USC 70002
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 November 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: the ignitability of combustible materials shall be restricted. PSCO observed profile useof rags soaked inflammable liquid used to control leaks on generator set, F.O. purifiers, and F.O. circulation pumps and air compressors.
74 SOLAS (09) II-2/4.1.3
10c
Action required: 10 - Deficiency Rectified
Resolved 13 November 2024
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 13 November 2024
Resolved
Firefighting systems and appliances shall be kept in good working order...
PSCO observed one fire hose with a broken gasket one fire hose with a pinhole leak.
74 SOLAS II-2 / 14.2.12
10c
Action required: 10 - Deficiency Rectified
Resolved 13 November 2024
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 November 2024
Resolved
Water closets provided wiht an ample flush of water available at all times and independently controlled...
PSCO Observed toilets were secured and not available to flush
ILO 147 Reg. 21(f) pg. 37
46 USC 70002
10c
Action required: 10 - Deficiency Rectified
Resolved 13 November 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2024
Resolved
Flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement approved by the administration. PSCO observedthe steering gear compartment used as a flammable liquid locker with no fire-extinguishing arrangement
74 SOLAS(09) II-2/10.6.3.2
10c
Action required: 10 - Deficiency Rectified
Resolved 13 November 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 November 2024
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed multiple catch-pans filled with flammable liquids on generators sets, F.O. Purifier, Heat Exchangers, and waste oil tank.
74 SOLAS(09) II-2/2.1.1
10c
Action required: 10 - Deficiency Rectified
Resolved 13 November 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 13 November 2024
Resolved
The company and ship should establish procedures to ensure that the ship is maintained in conformity with the provisions of relevant rules and regulations and with any additional requirements which may be established by the company.
PSCO observed computer passwords permanently marked on a bulkhead, a practice not allowed as per vessel's safety management manual.
74 SOLAS (20) IX/3.1
ISM Code 10.1
10c
Action required: 10 - Deficiency Rectified
Resolved 13 November 2024