MADELEINE MARIE is a 2002 towing vessel. The Coast Guard has recorded 17 inspections since 2004, most recently in July 2026, along with 64 deficiencies, 2 operational controls and 2 casualty investigations between 2004 and 2016.
Records from 2004 to 2026. Most recent: inspection, 7 July 2026.
- Built
- 2002
- Last inspected
- 7 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 64 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2004–2016
Identity
1105317
WDJ8230
18317
Flag
UNITED STATES
367710820
Maury page id
psix-18317
Inspections, by type
…with no type recorded5
Years with a record
11 calendar years (2004–2026)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 21.0 ft × 8.0 ft
Registered tonnagegross 79 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEPHEN GOLENSKI · MERRITT ISLAND, FL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it79 - Simplified, Gross Ton
63 - Simplified, Net Ton
63 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ8230MMSI 367710820 · active · compulsorily equipped · granted 29 November 2017, expires 29 November 2027
WDI5660MMSI 367710820 · cancelled · compulsorily equipped · granted 15 January 2016, cancelled 27 November 2017
WDG7959MMSI 367572590 · expired · compulsorily equipped · granted 30 April 2013, cancelled 15 July 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 17
7 July 2026
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8432115
4 June 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8151745
13 January 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8068920
27 July 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7752785
23 August 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7539627
17 February 2022
Internal Structural Exam · Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7397659
21 May 2021
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7195110
1 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6933963
1 July 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6732101
11 March 2019
Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6640463
11 June 2016
Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 5904310
11 June 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5905969
11 June 2016
Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 5940353
26 April 2013
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4643212
17 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4246583
10 December 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2261139
16 May 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2090424
Deficiency record · 64
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. MI observed a fuel leak from the Stbd Main Engine Fuel Pump (1 drop every 10 seconds). Repair to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. MI observed Steering Hydraulic components not secured by permanent means, causing hydraulic lines/valves to move while system is operating. Repair to the satisfaction of the Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 22 July 2025
Resolved
Decks and bulkheads designed to be watertight or weather tight must be maintained in that condition. MI observed a electrical pipe cracked leading to the pilot house resulting in water intrusion to electrical components. Repair to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 June 2025
Resolved
A fire-detection system is installed, tested, and maintained in accordance with the manufacturer's design manual. Marine Inspector observed the fire-detection panel showing a fault alarm. Repair to the satisfaction of the MI.
46 CFR 142.330(a)(2)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 June 2025
Resolved
A fire-detection system is installed, tested, and maintained in accordance with the manufacturer's design manual. Marine Inspector observed no testing equipment to ensure functionality of fire detection in the engine compartment. Repair to the satisfaction of the MI.
46 CFR 142.330(a)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 June 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Marine Inspector observed steering system shut down during underway trails on 3 occasions. Steering hydraulics were also observed to be improperly configured/mounted in engine room. Repair to the satisfaction of the MI.
46 CFR 143.205(a)
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 18 June 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention to the Port and Starboard Main Engine’s by providing a low lubricating oil pressure and high cooling water temperature alarms. Marine Inspector was not able to confirm working alarm set points on Port and Starboard Main Engine’s. Vessel requires confirmation of working alarm set points in the presence of a USCG Marine Inspector.
46 CFR 143.230
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 18 June 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention to the Port and Starboard Generators by providing a low lubricating oil pressure and high cooling water temperature alarms. Marine Inspector was not able to confirm working alarm set points on Port and Starboard Generators. Vessel requires confirmation of working alarm set points in the presence of a USCG Marine Inspector.
46 CFR 143.230
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 18 June 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention to the Hydraulic Steering System by providing a low fluid level alarm. Marine Inspector was not able to confirm the low level hydraulic steering alarm. Vessel requires confirmation of low fluid level alarm in the presence of a USCG Marine Inspector.
46 CFR 143.230
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 June 2025
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Maine Inspector observed vessel's installed whistle not functioning. Repair to the satisfaction of the MI.
33 CFR 83.33 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2025
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch (PSI) maximum allowable working pressure (MAWP) must be equipped with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Marine Inspector observed no pressure relief valve tag or documentation attesting to relieving pressure PSI. Provide relief valve documentation and/or valve tag approving relief pressure to the MI.
46 CFR 143.300 (a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2025
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Marine Inspector observed circuit breaker in engine compartment not labeled with specific equipment each breaker energizes. Repair to the satisfaction of the MI.
46 CFR 143.400 (d)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 18 June 2025
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include: Padlocking the seacock in the closed position. Marine Inspector sewage discharge valve unlocked in the closed position. Repair to the satisfaction of the MI.
33 CFR 159.5 (b)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 18 June 2025
Resolved
Every towing vessel equipped with an inflatable survival craft must have, in conspicuous places near each inflatable survival craft, approved placards or other posted instructions for launching and inflating inflatable survival craft. Marine Inspector observed no posted instructions for launching/inflating the vessels inflatable survival craft near the stowage location. Provide placard's or posted instructions to the satisfaction of the MI.
46 CFR 141.320
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 18 June 2025
Resolved
All pressure vessels must have the maximum allowable working pressure (MAWP) indicated by a stamp, nameplate, or other means visible to the crew. Marine Inspector observe pressure vessel without MAWP indicated on tank. Repair to the satisfaction of the MI.
46 CFR 143.300 (c)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 May 2025
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by 136.202.
The vessel must obtain a valid COI prior to conducting cargo operations (pushing/pulling).
46 CFR 136.200
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 August 2023
Resolved
The owner or managing operator of an existing vessel not operating under a stability document must be able to show at least one of the following:
1. The vessel's operation or a history of satisfactory service does not cause the stability of the vessel to be questioned by either the Coast Guard or a TPO engaged to perform an audit or survey.
2. The vessel performs successfully on operational tests to determine whether the vessel has adequate stability and handling characteristics.
3. The vessel has a satisfactory stability assessment by means of giving due consideration to each item that impacts a vessel's stability characteristics which include, but are not limited to, the form, arrangement, construction, number of decks, route, and operating restrictions of the vessel.
MI observed that a COI on board was endorsed for a coastwise route; however, there is no evidence of the above requirements being conducted. Until stability is
proven vessel is limited to a lakes, bays, and sounds
route.
46 CFR 144.300(b)(1)-(3)
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 August 2023
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm).
MI observed gauge indicating pressure was inoperable, and observed pressure was questionable to the standard.
46 CFR 142.325(a)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 August 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
MI observed both aft hatches leading into the engine room had wasted gaskets, and allowed water to ingress when tested with hose. In addition the stbd side hatch was missing it's handle.
46 CFR 140.610(b)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 August 2023
Resolved
Remote fuel shutoffs must be operable from a safe place outside the space where the valve is installed.
MI observed that multiple remote fuel shut offs were inoperable.
46 CFR 143.260(d)
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 August 2023
Resolved
The fire detection system must be installed, tested, and maintained IAW the manufacturers design manual.
The fire detection panel had ground faults and was unable to be tested.
46 CFR 142.330
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure.
Dead end wires were found in the engine room above the battery charger.
46 CFR 143.400
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2023
Resolved
Exposed hazards such as rotating machinery must be protected by a cover, guard, or rail.
The damper on the forward end of both engines need a guard installed. Stbd engine needs a guard over the alternator pulleys.
46 CFR 144.820
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 August 2023
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
MI identified an accumulation of oil in engine room bilge well.
46 CFR 142.220 (a)
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 August 2023
Resolved
Each towing vessel must be fitted with a general alarm that has installed in the engine room a supplemental flashing red light with a sign that reads Attention General Alarm – When Alarm Sounds Go to Your Station.
Vessel did not have the flashing red light and sign installed in the engine room.
46 CFR 143.235
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 August 2023
Resolved
When the towing vessel is underway the EPIRB must be stowed in its float free bracket in a manner so it will float free.
The hydrostatic release on the EPIRB was past its expiration date.
46 CFR 141.380
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 August 2023
Resolved
Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds.
Marine inspector observed that the vessel did not have a means of obtaining blood pressure.
46 CFR 140.435
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 2 August 2023
Resolved
Each vessel with a marine sanitation device must have manufacturers instructions containing directions for the type and quantity of the chemicals that are required to operate the device, including instructions on the proper handling, storage, and use use of these chemicals.
Marine inspector observed that the vessel did not have the instructions onboard.
33 CFR 159.57(a)(5)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 2 August 2023
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the EPA under 40 CFR 140.3 or 140.4, the operator
must secure each Type I or Type II device in a manner
which prevents discharge of treated or untreated sewage.
Marine inspector observed sewage valve for overboard discharge was unlocked.
33 CFR 159.7(b)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 August 2023
Resolved
The towing vessel record must have a record of the navigational assessment and the navigational training required by 46 CFR 140.635 and 140.645 respectively.
Marine inspector observed that the vessel was not logging any of the navigation assessments or navigation training.
46 CFR 140.915
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 August 2023
Resolved
Each lifeline on a lifebuoy must have a breaking strength of at least 5 kilonewtons and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
MI identified multiple lifebuoys with deteriorated lifelines and insufficient retro-reflective material.
46 CFR 141.350(c)(1)(v)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2023
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with § 143.245. All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew.
MI identified pressure vessel for compressed air with no visible indication of the MAWP for the pressure vessel and no evidence that the relief valve had been tested.
46 CFR 143.300
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 August 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
MI identified ventilation openings for engine room with no means of closing off ventilation.
46 CFR 144.605
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 July 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
The vessel has a COI anniversary date of 15Apr. The vessel was required to have an annual inspection no later than 15Jul23, and the vessel has not had an annual inspection for this year.
46 CFR 137.200
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 July 2022
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. COD expired 30 November 2021.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2022
Resolved
ll portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Inspection was past due in June, 2022.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 July 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. No smoke detector in berthing off galley/messdeck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2022
Resolved
ifejackets must have the following attachments and fittings: Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket and each lifejacket must have a whistle firmly secured by a cord to the lifejacket. Missing both light and whistle on all lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2022
Resolved
At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. All lifebuoys had lifelines attached.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2022
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Bridge to Bridge license was expired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2022
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. Navigational assessments were not being conducted.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 July 2022
Resolved
Each towing vessel must be fitted with a general alarm that: Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station”. No signage in engine room for general alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 July 2022
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. First aid kits were expired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2022
Resolved
The drydock examination must be conducted while the vessel is hauled out of the water. The following worklist items a) through i) shall be addressed and approved by a Marine Inspector before the vessel is refloated. The remaining worklist items shall be completed before receiving credit for drydock.
a) Replace starboard aft rudder post flange bolts
b) Determine hull thickness at starboard shaft tube and bottom plating in vicinity of propellers
c) Replace both propellers and water-lubricated bearings
d) Insert hull plating on starboard side aft in line with engine room door
e) Insert hull plating on starboard side in vicinity of forward compartment bulkhead
f) Insert hull plating on port side turn of the bilge outside of keel cooler
g) Weld wash in the following areas: port and starboard side turn of the bilge amidships and forward, three longitudinal butt welds on forward rake hull plating
h) Wasted flange on starboard shaft packing gland
i) Starboard fuel tank; broken welds vertical stiffener and transverse frame (2nd from aft bulkhead)
j) Two stanchions supporting deck grating over steering gear damaged
k) Two vents wasted on port side in vicinity of the lazarette scuttles
l) Recoat potable water tanks
m) Unseal two deck scuttles for lazarette access
n) Wasted stiffener on port amidships bulkwark in vicinity of line roller
o) Descale for further inspection: port and starboard forward bitts on outboard sides, starboard aft bitt on outboard side, forward main deck in vicinity of centerline bitt and starboard side winch
p) Remove forward compartment decking for inspection of internal structure of vessel
q) Insert required on starboard push knee in forward compartment
r) Wasted bulwark stiffeners on starboard side amidships and starboard aft in vicinity of lazarette scuttle
s) Wasted rudder stop chains
t) Proper tray for starboard forward generator battery
u) Improper sealing of bulkhead penetrations in fiddley
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2021
Resolved
ELECTRICAL CONNECTIONS MUST BE SUITABLY INSTALLED TO PREVENT THEM FROM COMING LOOSE THROUGH VIBRATION OR ACCIDENTAL CONTACT. THE PORT AFT BATTERY HAD TEMPORARY CLAMPS. INSTALL PERMANENT ELECTRICAL CONNECTIONS.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 21 May 2021
Resolved
EACH WIRE MUST BE INSTALLED IN A MANNER TO PREVENT CONTACT WITH PERSONNEL, MECHANICAL HAZARDS, AND LEAKING FLUIDS. MI OBSERVED WIRES UNDER STEERING CONSOLE EXPOSED AND WIRES PROTRUDING FROM MAIN ENGINE GAUGES EXPOSED. ENSURE THESE WIRE ARE PROPERLY COVERED.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 May 2021
Resolved
TOWING VESSELS MUST CARRY 3 DAY AND 3 NIGHT VISUAL DISTRESS SIGNALS WHEN OPERATING ON LAKES, BAYS, SOUNDS, AND RIVERS WITHIN 3 NAUTICAL MILES. VESSEL HAD 3 NIGHT AND ONE DAY DISTRESS SIGNAL. PROVIDE APPROPRIATE AMOUNT OF DISTRESS SIGNALS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 May 2021
Resolved
THE MAIN ENGINES MUST BE EQUIPPED WITH RPM GUAGES. MI DID NOT OBSERVE ANY RPM GAUGES AT THE MACHINERY SPACE FOR MAIN ENGINE RPM. INSTALL MAIN ENGINE RPM GUAGE IN THE MACHINERY SPACE.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 21 May 2021
Resolved
EACH REMOTE FULE SHUTOFF VALVE CONTROL MUST BE MARKED INDICATING THE PURPOSE. NO INDICATIONS WERE PRESENT. PROVIDE INDICATIONS FOR EACH VALVE AT THE REMOTE CONTROL.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 May 2021
Resolved
FIRE DETECTION SYSTEM PANEL THAT INCLUDES LABELS FOR EACH AREA. FIRE DETECTION PANEL DID NOT INDICATE EACH AREA IT PROTECTED. PROVIDE IDENTIFICATION FOR EACH AREA AS APPROPRIATE.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 May 2021
Resolved
ALL PORTABLE FIRE EXTINGUISHER, SEMI-PORTABLE FIRE EXTINGUISHERS MUST BE INSPECTED AT LEAST ONCE EVERY 12 MONTHS AND FREQUENCY SPECIFIED BY NFPA 10. NO DOCUMENTATION OF MAINTENANCE WAS PROVIDED. PROVIDE MAINTENANCE FOR ANNUAL AND OTHER INSPECTIONS.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 21 May 2021
Resolved
THE COAST GUARD WILL ISSUE A MEDICAL CERTIFICATE TO MARINER MEETING MEDICAL AND PHYSICAL STANDARDS FOR MERCHANT MARINERS AND WILL BE ISSUED BASED UPON ENDORSEMENT. MARINER UNABLE TO PROVIDE MEDICAL CERTIFCATE. PROVIDE PROOF OF MEDICAL CERTIFICATE.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 May 2021
Resolved
Each towing vessel must have a fire-detection system that is installed , tested and maintained in accordance with the manufacturer's design manual. Vessel installed a battery cutoff switch for on fire-detection panel's secondary source of power. Uninstall battery cutoff switch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 May 2021
Resolved
Propulsion machinery must be maintained to ensure proper operation. Port shaft packing gland is leaking at approximately 4 drops per second while moored. Repair leak.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 May 2021
Resolved
Each vessel required to have a Certificate of Inspection is subject to the annual inspection fee listed in Table 2.10-101 for its vessel category. USCG records show an outstanding balance of $13.06 for the annual user fee. Vessel must settle any balance for annual fees or late penalties with FINCEN Customer Service.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2020
Resolved
All fire-detection systems must be inspected or tested at least once every 12 months. The fire-detection system has not been tested or inspected in over a year. Inspect fire-detection system and provide proof.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2020
Resolved
Each towing vessel must be arranged so that any essential system identified by the cognizant OCMI can be energized from two independent sources. The motor controller for both the fire pump and the bilge pump were inoperable. Repair both motor controls.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 April 2020
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be automatic. The emergency lighting did not turn on when the vessel went from shore power to ships power. Repair emergency lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2020
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. 1. The port/stbd shaft packing salt water containment box bilge pumps are plugged into an outlet that is spliced into an extension cord,
zipped tied to a pipe. Install proper outlet that is powered from a distribution panel. 2. There are 5 dead ended wires under the forward bridge console. Determine what these wires are for and either connect them
properly, remove them, or terminate them into a junction box.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 April 2020
Resolved
Each integral fuel tank must have a vent fitted with a 30 - by - 30 mesh corrosion resistant flame screen. The four fuel oil vents do not have 30 - by - 30 mesh flame screens. Install proper flame resistant mesh screen.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 April 2020
Resolved
A fixed fire pump must be capable of delivering water at a pitot-tube pressure of at least 50 pounds per square inch (psi). The gauge of the fire hose was only reading 36 psi. Determine if the hose pressure or the gauge is not working properly and repair or replace in kind.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 April 2020
Resolved
A towing vessel must carry adequate and up to date nautical publications. Vessel did not have a Coast Pilot on board. Obtain current edition of Coast Pilot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2019
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Bilge suction not operational. Demonstrate operation of bilge pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 April 2019
Resolved
The owner, managing operator, or master of each towing vessel must maintain the required navigational-safety equipment in a fully-functioning, operational condition. Vessel does not have day shapes. Provide day shapes.
Casualty record · 2
16 May 2004Routine · role: Involved in a Marine Casualty · activity 2090424
11 June 2016Routine · role: Involved in a Marine Casualty · activity 5905969
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
HUBERT BAYS (2004–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.