← All vessels
SENTINEL
Commercial Fishing Vessel · Fishing Vessel class · Built 1980s · USCG Northwest District (CGD-NW) · Other hulls named SENTINEL
SENTINEL is a 1980 commercial fishing vessel. The Coast Guard has recorded 66 inspections since 1985, most recently in January 2011, along with 139 deficiencies and 1 casualty investigation in 2004.
Records from 1985 to 2011. Most recent: inspection, 6 January 2011.
- Built
- 1980
- Last inspected
- 6 January 2011
- Documentation
- No Operation - PM · documentation file of 10 September 2026
- Deficiencies
- 139 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2004
Identity
619996
WDK4441
183267
Flag
UNITED STATES
368055230
Maury page id
psix-183267
Inspections, by type
…with no type recorded10
Years with a record
27 calendar years (1985–2011)
The 66 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)43.0 ft × 15.0 ft × 7.6 ft
Registered tonnagegross 31 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAMSON MARINE · SHERWOOD, OR, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOMER, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK4441MMSI 368055230 · active · voluntarily equipped · granted 17 August 2018, expires 17 August 2028
WDE9138MMSI 367413920 · expired · compulsorily equipped · granted 9 June 2009, cancelled 10 August 2019
WDE6996MMSI 367387560 · cancelled · voluntarily equipped · granted 11 December 2008, cancelled 19 May 2009
WYR3292MMSI not assigned · expired · compulsorily equipped · granted 1 April 1997, cancelled 1 September 2007
WCQ9315MMSI not assigned · expired · compulsorily equipped · granted 26 April 1995, cancelled 2 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 66
6 January 2011
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3920776
15 March 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3692367
18 March 2009
COI Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3436659
10 December 2008
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3377843
2 December 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3303897
4 June 2007
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2915745
3 April 2007
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2901887
29 September 2006
Construction Oversight
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2792856
23 August 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2757706
24 May 2005
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2366381
6 April 2005
Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2308731
19 October 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2224910
12 August 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2160934
10 February 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2001877
5 January 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1975109
25 August 2003
MARPOL Annex V Examination · MARPOL Annex I Examination · Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1880900
2 May 2003
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1896129
4 June 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1628194
19 February 2002
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1487611
24 July 2001
Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1436605
18 June 2001
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1417311
24 May 2001
Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382270
24 July 2000
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 821187
1 June 2000
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403144
8 July 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1384197
7 June 1999
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1365241
15 July 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 794688
11 June 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 794686
4 June 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1398926
9 July 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1116998
1 July 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 777490
2 June 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1453361
30 April 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1099085
10 April 1997
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385960
24 March 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1107315
13 January 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1102507
30 July 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1402299
9 July 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1087538
16 December 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 715289
5 October 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 205532
5 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1377440
18 April 1995
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1377382
11 April 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 849911
7 April 1995
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1448634
20 June 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1022603
2 June 1994
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1354741
24 July 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 841106
15 June 1993
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359588
5 November 1992
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257272
28 July 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 962334
10 July 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1262936
18 June 1991
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1249662
7 November 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 921177
24 July 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1296005
21 November 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 920741
21 November 1989
Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1229944
8 November 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1036850
24 August 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1203159
14 July 1989
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 886974
20 October 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 890067
7 July 1988
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1032813
9 June 1988
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1200454
29 October 1987
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1019645
9 July 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1023199
16 June 1986
Credit Drydock · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 992523
25 June 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 987703
Deficiency record · 139
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 January 2011
Resolved
Make proper repairs to a 1.5" x .5" fracture in the exhaust piping prior to operating with pax. Fracture is located on STBD MDE exhaust between the Manifold and the water cooling.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 January 2011
Resolved
Make proper welding repairs to cracked weld on the Port MDE exhaust piping at first weld seam aft of the water injection manifold prior to carrying pax.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 20 August 2008
Resolved
Owner/Operator has let license lapse, needs to provide proof of a licensed master to operate the vessel.
Personnel › Training › First Aid/CPR
Issued 20 August 2008
Resolved
Prove at least one of the required crew has valid CPR/First Aid training.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 August 2008
Resolved
Prove enrollement of crew in Proper Drug Consortium.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 August 2008
Resolved
Provide evidence of pre-employment drug testing for master and crew.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 20 August 2008
Resolved
Provide unexpired hydrostatic release for the liferaft.
Lifesaving › Inflatable Liferafts › Servicing
Issued 20 August 2008
Resolved
Provide proof of proper servicing of the installed Liferaft.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 August 2008
Resolved
Provide proof of testing of the installed fire extinguisher systems for the engine room and generator room.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 August 2008
Resolved
Provide up to date current and tide tables for operating area.
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 August 2008
Resolved
Properly label remote fuel shutoffs so they are visible.
Fire Fighting › Ventilation Systems › Ducts
Issued 20 August 2008
Resolved
Provide proper ventilation shutoffs or covers for engineroom vents (3).
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 August 2008
Resolved
Remove or properly install wiring to flood lights on aft flying bridge.
Communications › Radio Communications › EPIRB
Issued 20 August 2008
Resolved
Properly attach cotter pin lanyard.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 August 2008
Resolved
Conduct underway drills for attending marine inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 August 2008
Resolved
Provide documentation of completion of all required drills.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 19 April 2007
Resolved
Provide proof of pre-employment testing of captain and crew prior to operating with passengers.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 April 2007
Resolved
Properly label life jacket locker on deck.
Engineering › Bilge Water Management System › Valve
Issued 19 April 2007
Resolved
Provide check valves or stop/check valves at bilge system manifold.
Communications › Radio Communications › EPIRB
Issued 19 April 2007
Resolved
Provide documentation attesting to the renewal of EPIRB registration. Vessel restricted to less than 3 NM.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 April 2007
Resolved
Provide documentation attesting to the emergency equipment maintenance, i.e. monthly checks of fire extinguishers, etc...
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 April 2007
Resolved
Provide CG Light List and Coast Pilot.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 19 April 2007
Resolved
Properly repair RPM gauge for Stbd MDE
Engineering › Fuel Oil Service System › Valve
Issued 19 April 2007
Resolved
Properly label fuel cut out valves.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 April 2007
Resolved
Properly make all watertight bulkheads watertight.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 August 2006
Resolved
Provide proof of full compliance with drug and alcohol program as outlined in 46 CFR 16. Employer policy, hotline numbers posted, etc...
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 August 2006
Resolved
Provide documentation attesting to the completion of all required drills.
Navigation › Piloting/Steering › Marine Charts
Issued 21 August 2006
Resolved
Provide current and/or corrected charts and tide tables.
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 August 2006
Resolved
Prove proper operation of installed radar.
Communications › Audible Communications › Bell
Issued 21 August 2006
Resolved
Provide bell or demonstrate other sound producing device meeting navigation rules.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 21 August 2006
Resolved
Prove proper operation of MF radio.
Communications › Radio Communications › EPIRB
Issued 21 August 2006
Resolved
Provide new EPIRB battery and install new EPIRB hydro release.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 August 2006
Resolved
Replace worn retro reflective material on 13 adult lifejackets and 1 Childs.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 21 August 2006
Resolved
Replace light on 4 adult lifejackets and 2 Childs.
Lifesaving › Lifebuoys › Serviceable
Issued 21 August 2006
Resolved
Replace life-ring buoy including life-line and waterlight line.
Electrical › Electric Generation Source (service) › Generator
Issued 21 August 2006
Resolved
Prove proper operation of installed generator and automatic generator shutdown during operation of fixed fire system.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 August 2006
Resolved
Provide method for closing ventilation during operation of fixed fire fighting system.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 21 August 2006
Resolved
Properly repair leaks in both MDE exhaust systems.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 August 2006
Resolved
Tighten hose clamps on water cooling system on stbd MDE.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 August 2006
Resolved
Investigate and determine cause of strong fuel odor in fuel tank space.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 21 August 2006
Resolved
Properly repair vent line to fuel tanks.
Engineering › Bilge Water Management System › Not Operational
Issued 21 August 2006
Resolved
Prove proper operation of installed bilge suction system.
Engineering › Bilge Water Management System › Pump
Issued 21 August 2006
Resolved
Provide portable hand bilge pump.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 August 2006
Resolved
Properly dead-end all electrical wires and properly splice electrical wires.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 21 August 2006
Resolved
Prove proper operation of MSD.
Documentation › Markings/Placards › Lifejacket Placard
Issued 21 August 2006
Resolved
Post lifejacket donning placard for horse collar lifejackets.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 24 May 2005
Resolved
Provide proof of Drug Testing Program enrollment. 46 CFR 16. Correct to the satisfaction of the attending marine inspector. Vessel not permitted to operate with passengers until corrected.
Communications › Radio Communications › EPIRB
Issued 24 May 2005
Resolved
Provide/renew EPIRB registration. 46 CFR 180.64. Correct to the satisfaction of the attending marine inspector. Vessel not permitted to operate until corrected.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 May 2005
Resolved
Prove proper operation of radar. Picture is unclear. 46 CFR 184.404. Correct to the satisfaction of the attending marine inspector. Vessel not permitted to operate with passengers at night or in restricted visibility until corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 May 2005
Resolved
Service all fire fighting appliances (fixed system and portables). 46 CFR 181.500/NFPA 10. Correct to the satisfaction of the attending marine inspector. Vessel restricted from carrying passengers until corrected.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 May 2005
Resolved
Install remote fuel shut off valve handles & reach rods. 46 CFR 182.455. Correct to the satisfaction of the attending marine inspector.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 24 May 2005
Resolved
Install bonding wire and double clamp fuel fill fitting. 46 CFR 182.440. Correct to the satisfaction of the attending marine inspector.
Communications › Radio Communications › EPIRB
Issued 12 August 2004
Resolved
Confirm EPIRB registration with NOAA. Currently expired 06/03. 46 CFR 180.64. Correct to the satisfaction of the attending marine inspector.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 12 August 2004
Resolved
Test SSB to the satisfaction of the USCG as discussed. 47 CFR 80. Correct to the satisfaction of the attending USCG Rep.
Documentation › Markings/Placards › Warning Signs
Issued 12 August 2004
Resolved
Provide and install fuel shut off valve location sign in cabin. 46 CFR 185.608. Correct to the satisfaction of the attending marine inspector.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 12 August 2004
Resolved
Provide and install 30 x 30 mesh screen on port and starboard side fuel tank vents. 46 CFR 182.440. Correct to the satisfaction of the attending marine inspector.
Engineering › Bilge Water Management System › Hose
Issued 12 August 2004
Resolved
Replace hose on submersible bilge pump in lazarette with one of suitable material as discussed. 46 CFR 182.520. Correct to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 August 2004
Resolved
Replace wiring for high level alarm and bilge pump with approved type. 46 CFR 183.340. Correct to the satisfaction of the attending marine inspector.
Engineering › Bilge Water Management System › Not Installed
Issued 12 August 2004
Resolved
Provide individual "visual" high level bilge alarms for each compartment with thru hull fittings below the W/L. Visual indicators must be located at operating station. 46 CFR 182.530. Correct to the satisfaction of the attending marine inspector.
Documentation › Certificates/Documents
Issued 25 August 2003
Resolved
Provide copy of Certificate of Documentation. Keep original on board. Vessel has valid COD as per MISLE but no copy was available for inspection. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Navigation › Piloting/Steering
Issued 25 August 2003
Resolved
Provide currently corrected copies of USCG Light List, Coast Pilot, Tide and Tidal current tables. Applicable extracts of these publications are acceptable. LEGACY COMPONENT DESC: Publications
Accommodation/Occupational Safety › Occupational Safety
Issued 25 August 2003
Resolved
Raise rail height to meet 11MAR1996 requirements (min 36"), to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Deck Rail
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 August 2003
Resolved
Service portable F/E's (1 B-I & 1 B-II). B-I must be hydrostatically tested. Provide same type and size during service period. Vessel may not operate with discharged extinguishers. LEGACY COMPONENT DESC: Pressure Gauge/Hydrostatic testing
Engineering › Freshwater System (jacketwater cooling)
Issued 25 August 2003
Resolved
Replace hose on generator prime mover running from heat exchanger to expansion tank. LEGACY COMPONENT DESC: Hose
Accommodation/Occupational Safety › Occupational Safety
Issued 25 August 2003
Resolved
Provide guard for alternator on generator prime mover, to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 25 August 2003
Resolved
Make fixed fire fighting system for generator space operate as designed (shut down not operable), to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Operating Controls
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 25 August 2003
Resolved
Make fixed fire fighting system for main engine space operate as designed (port engine starts w/out activating the override switch), to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Operating Controls
Engineering › Sea-water System (primary cooling)
Issued 25 August 2003
Resolved
Double clamp all vital system hoses (fuel, cooling, hydraulic) as necessary. LEGACY COMPONENT DESC: Vital systems hoses
Engineering › Shafting/Propeller Arrangements
Issued 25 August 2003
Resolved
Tighten shaft packing as necessary to reduce quantity of water intrusion. LEGACY COMPONENT DESC: Propeller Shaft
Pollution Prevention/Response › Prevention Equipment
Issued 25 August 2003
Resolved
Secure MSD tank and make operable as type II or type III as discussed. Passengers currently have no toilet available until vessel is operating beyond 3 miles from land. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Engineering › Fuel Oil Storage/Transfer System
Issued 25 August 2003
Resolved
Make all fuel shut off valves operable. Mount a dedicated tool to bulkhead nearby to use for exercising valves. Label/mark bulkhead with "Fuel shut off" and direction of rotation. LEGACY COMPONENT DESC: Shut-off Valves
Engineering › Bilge Water Management System
Issued 25 August 2003
Resolved
Make visual alarm for bilge pump operation in lazarette operable. LEGACY COMPONENT DESC: High water alarm
Lifesaving › Inflatable Liferafts
Issued 25 August 2003
Resolved
Vessel restricted to operating with 25 passengers until lifesaving equipment meets COI requirements for passengers on Coastwise voyages. LEGACY COMPONENT DESC: Capacity
Lifesaving
Issued 18 June 2001
Resolved
PROVIDE INFLATABLE SURVIVAL CRAFT PLACARD.
Documentation
Issued 18 June 2001
Resolved
PROVE VALID FCC OPERATOR LICENSE .
Navigation
Issued 18 June 2001
Resolved
Prove proper operation of naviagational lights, (anchor light)
Navigation
Issued 18 June 2001
Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO
Documentation
Issued 24 May 2001
Resolved
PROVIDE FCC OPERATOR'S LICENSE FOR VESSEL'S OPERATOR.
Construction/Loadline
Issued 24 May 2001
Resolved
MAKE PERMANENT REPAIRS TO DELAMINATED STERN AND KEEL AREAS (APROX; BOTTOM OF KEEL UP 10"/STERN FWD 24" AND BETWEEN 14" AND 20" FROM KEEL/BETWEEN 2" AND 6" FROM STERN).
Lifesaving
Issued 24 May 2001
Resolved
PROVIDE ALL LIFEJACKES WITH PFD LIGHTS.
Lifesaving
Issued 24 May 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 1 June 2000
Resolved
Install check valves at thru-hull fitting for all electric rule bilge_x001C_ pumps.
Engineering
Issued 1 June 2000
Resolved
Install bonding to common ground on steering compartment fuel tank IAW 46CFR182.440 (b) (4).
Construction/Loadline
Issued 1 June 2000
Resolved
Install high level bilge alarm in forward fuel tank compartment. 46CFR182.530.
Lifesaving
Issued 8 July 1999
Resolved
INSTALL NEW HYDROSTATIC RELEASE FOR EPIRB, PRIOR TO THE CARRIAGE OF PASSENGERS.
Construction/Loadline
Issued 8 July 1999
Resolved
PROVE PROPER OPERATION OF ENGINE DRIVEN BILGE PUMP.
Documentation
Issued 4 June 1998
Resolved
OBTAIN VALID FCC RADIO SAFETY CERTIFICATE.
Lifesaving
Issued 4 June 1998
Resolved
RENEW EXPIRED FIRST AID ITEMS._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 4 June 1998
Resolved
RENEW VALVE IN BILGE LINE TO ALLOW PROPER OPERATION OF ENGINE DRIVEN BILGE PUMP.
Engineering
Issued 4 June 1998
Resolved
RENEW INSULATION ON BAD SECTION OF EXHAUST - ENGINE PORT AND STBD.
Navigation
Issued 4 June 1998
Resolved
VESSEL LIMITED TO COASTWISE ROUTE UNTIL SINGLE SIDE BAND IS OPERABLE.
Lifesaving
Issued 2 June 1997
Resolved
PROPERLY PATCH THE CRACKS ON THE OUTBOARD 12 CAPACITY LIFEFLOAT.
Lifesaving
Issued 2 June 1997
Resolved
REPAIR OR REPLACE THE DAMAGED PADDLE FOR THE 10 PERSON LIFEFLOAT.
Lifesaving
Issued 2 June 1997
Resolved
PROVIDE RETROREFLECTIVE TAPE FOR THE LIFERING.
Lifesaving
Issued 2 June 1997
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE NEW HYDROSTATIC RELEASE FOR THE EPIRB.
Navigation
Issued 2 June 1997
Resolved
PROVIDE UPDATED AND CURRENT NAVIGATION CHARTS AND PUBLICATIONS.
Unknown
Issued 2 June 1997
Resolved
PROVIDE INFORMATION ON THE COMPANY DRUG TESTING EMPLOYEE ASSISTANCE PROGRAM.
Documentation
Issued 2 June 1997
Resolved
POST THE MOST CURRENT STABILITY LETTER ONBOARD THE VESSEL.
Lifesaving
Issued 2 June 1997
Resolved
PROVIDE PFD DONNING PLACARD.
Accommodation/Occupational Safety
Issued 2 June 1997
Resolved
MAKE THE FORWARD EMERGENCY ESCAPE HATCH OPERABLE FROM BOTH SIDES.
Lifesaving
Issued 2 June 1997
Resolved
REMOVE OR SERVICE THE 6 PERSON INFLATABLE LIFERAFT.
Construction/Loadline
Issued 10 April 1997
Resolved
MAKE PROPER REPAIRS TO SPOOL PIECE IN WAY OF PORTSIDE GENERATOR OVERBOARD DISCHARGE VALVE. TO BE COMPLETED PRIOR TO PLACING THE VESSEL BACK IN THE WATER.
Unknown
Issued 30 July 1996
Resolved
CONDUCT UNDERWAY DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Engineering
Issued 18 April 1995
Resolved
Demonstrate remote engine start and stop.
Engineering
Issued 7 April 1995
Resolved
Port and starboard engine exhaust had rubber baffles installed to quit engine sounds. Baffles had worn and were hanging down into the exhaust piping. 835 issued to remove port and starboard baffles prior to carring passengers for hire.
Engineering
Issued 7 April 1995
Resolved
Vessels port main engine removed for rebuild. 835 issued to prove proper operation of both main engines prior to carring passengers for hire.
Construction/Loadline
Issued 2 June 1994
Resolved
REMOVE GARDEN STYLE INTAKE HOSE FROM SALT WATER WASHDOWN PUMP AND REPLACE WITH PROPER HOSE AND DOUBLE CLAMP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Navigation
Issued 2 June 1994
Resolved
PROVIDE A CURRENT LIGHT LIST.
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
PROVIDE A NO DISCHARGE PLACARD AT THE 'Y' VALVE FOR THE MARINE SANITATION DEVICE.
Navigation
Issued 15 June 1993
Resolved
MOVE MASTHEAD LIGHT TO 2.5 METERS(8.2 FEET) ABOVE THE GUNWALE.
Documentation
Issued 10 July 1992
Resolved
PROVIDE ON BOARD A VALID FCC RADIOTELEPHONY SAFETY CERTIFICATE IAW 47 CFR.
Navigation
Issued 18 June 1991
Resolved
SHOW OPERATION OF RADAR UNIT.
Construction/Loadline
Issued 18 June 1991
Resolved
SHOW OPERATION OF ENGINE DRIVEN BILGE PUMP.
Engineering
Issued 18 June 1991
Resolved
SHOW OPERATION OF PROPULSION MACHINERY.
Lifesaving
Issued 18 June 1991
Resolved
PROVIDE 6 DAY AND 6 NIGHT FLARES.
Electrical
Issued 18 June 1991
Resolved
SHOW OPERATION OF DIESEL GENERATOR.
Electrical
Issued 18 June 1991
Resolved
PROVIDE A SEPARATE DISCHARGE LINE FOR GENERATOR OVERBOARD RAW WATER_x001C_ DISCHARGE.
Electrical
Issued 18 June 1991
Resolved
MAKE PROPER ELECTRICAL CONNECTIONS TO LIGHT FIXTURE IN HEAD.
Electrical
Issued 18 June 1991
Resolved
REMOVE WIRING FROM OIL STOVE REMOVAL.
Navigation
Issued 18 June 1991
Resolved
PROVIDE FCC OPERATOR PERMIT.
Electrical
Issued 18 June 1991
Resolved
INSTALL 2 BLANKS FOR SWITCHBOARD LOCATED IN GENERATOR SPACE.
Electrical
Issued 18 June 1991
Resolved
PROVIDE GROUND STRAP FOR AFT FUEL TANK.
Deck/Cargo
Issued 24 August 1989
Resolved
VESSEL RESTRICTED TO RIVERS ROUTE UNTIL CRAB LIGHTS AND SUPPORT FRAME ARE REMOVED (AS PER RESULTS OF SIMPLIFIED STABILITY TEST CONDUCTED 24 AUGUST 1989).
Unknown
Issued 14 July 1989
Resolved
APPLY FOR A STABILITY TEST.
Electrical
Issued 14 July 1989
Resolved
SUBMIT PLANS FOR THE INSTALLED ISUZU GENERATOR AND ASSOCIATED ELECTRICAL INSTALLATION.
Electrical
Issued 14 July 1989
Resolved
SUBMIT PLANS FOR THE INSTALLED HIGH PRESSURE SODIUM LIGHTS.
Deck/Cargo
Issued 14 July 1989
Resolved
SUBMIT PLANS FOR THE INSTALLED CRAB BLOCK.
Construction/Loadline
Issued 14 July 1989
Resolved
PROVIDE RETAINING DEVICE FOR WATERTIGHT HATCH FOR THE AFTER LAZARETTE.
Electrical
Issued 14 July 1989
Resolved
PROVIDE FLAME IMPINGMENT BOWL FOR GENERATOR FUEL FILTER.
Electrical
Issued 14 July 1989
Resolved
PROVIDE A LEAD TRAY, OR OTHER MATERIAL RESISTANT TO DETERIORATING ACTION BY THE ELECTROLYTE, FOR THE GENERATOR'S STARTING BATTERY.
Lifesaving
Issued 14 July 1989
Resolved
REPAIR CRACKS AND HOLES IN LIFEFLOAT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Lifesaving
Issued 14 July 1989
Resolved
PLACE LIFEFLOAT SO THAT IT WILL FLOAT FREE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Navigation
Issued 14 July 1989
Resolved
REPAIR ANCHOR LIGHT.
Unknown
Issued 14 July 1989
Resolved
REPLACE FADED POLLUTION PLACARD.
Construction/Loadline
Issued 14 July 1989
Resolved
REPAIR CRACKS IN GEL COAT ON BOW ABOVE WATERLINE.
Documentation
Issued 14 July 1989
Resolved
OBTAIN AND POST A VALID FCC MARINE RADIO OPERATOR PERMIT.
Navigation
Issued 7 July 1988
Resolved
PROVIDE A STERN LIGHT WITH 135 DEGREE ARC TO COMPLY WITH RULES 21 AND 23 OFNAVIGATION RULES.
Electrical
Issued 7 July 1988
Resolved
REPLACE WIRE NUT CONNECTIONS ON FRESHWATER PUMP AND WASHDOWN PUMP WITH SOLDERED AND TAPED OR APPROVED CRIMP CONNECTIONS.
Engineering
Issued 7 July 1988
Resolved
REPLACE RACOR FUEL FITLERS WITH APPROVED MARINE FILTER OR INSTALL APPROVED MARINE FLAME IMPINGEMENT BOWLS AND BOTTOM PLUGS.
Casualty record · 1
5 January 2004Routine · role: Involved in a Marine Casualty · activity 1975109
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
ZOEA (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.