MAURY USCG vessel records Sign in
← All vessels

MAERSK IDAHO

MAERSK IDAHO is a 1999 freight ship. The Coast Guard has recorded 93 inspections since 2002, most recently in June 2026, along with 48 deficiencies, 9 operational controls and 12 casualty investigations between 2010 and 2021.

Records from 2002 to 2026. Most recent: inspection, 24 June 2026.

Built
1999
Last inspected
24 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9193264 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V7730
Flag
SINGAPORE
368660000
Maury page id
psix-1837

Inspections, by type

…with no type recorded33
Years with a record 20 calendar years (2002–2026)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it50698 - Convention (Subpart B), Gross Ton
29707 - Convention (Subpart B), Net Ton
61986 - Dead Weight, Ton
82327 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WKPMMMSI 368660000 · active · compulsorily equipped · granted 29 November 2018, expires 20 February 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 93

24 June 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8412464
14 January 2026 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8297532
11 November 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8266879
31 March 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8102401
17 February 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8080431
5 November 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029636
5 November 2024 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029670
17 September 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8003786
18 August 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7983830
12 August 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7976106
21 June 2024 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7939717
28 February 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7871390
27 October 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7821308
8 September 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7782429
13 February 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7633863
18 August 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7537484
8 August 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528303
6 August 2022 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7525857
16 November 2021 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7352252
15 November 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7352229
17 September 2021 Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 7314248
11 September 2021 Type not recorded
No type recorded · Activities Europe · Activity 7314241
9 April 2021 Administrative Inspection · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7171959
3 April 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7169000
8 March 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7153376
22 October 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7084149
30 August 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7046476
6 July 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7013817
4 June 2020 Administrative Inspection
Administrative · Activities Europe · Activity 6968620
4 February 2020 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6902314
8 January 2020 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6885044
6 January 2020 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6883249
6 December 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6868792
17 August 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6788486
9 May 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6683155
5 April 2019 Annual Inspection · MSP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6655621
13 January 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6609627
24 July 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6488923
6 July 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6495795
26 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6456402
28 March 2018 MTSA/ISPS Verification · Deficiency Check · MSP Annual Oversight · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6374237
11 February 2018 Deficiency Check · MSP Periodic Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6352221
2 February 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6348571
9 September 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6264947
5 April 2017 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6118042
9 January 2017 Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 6067889
9 December 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6055063
16 November 2016 In-Service Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 6042864
2 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6033997
24 October 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6028506
24 September 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6008092
31 May 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5892857
20 April 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5858349
6 April 2016 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847956
27 January 2016 Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 5804141
24 January 2016 Type not recorded
No type recorded · Activities Europe · Activity 5807031
11 December 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5830200
30 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5233702
24 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5233700
24 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5807911
23 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5726410
31 July 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5201709
6 May 2014 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4851463
21 September 2011 Type not recorded
No type recorded · Activities Europe · Activity 4162056
26 August 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4127718
8 July 2011 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4074004
3 July 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4066234
15 February 2011 Type not recorded
No type recorded · Activities Europe · Activity 3946221
6 February 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3941312
30 January 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3936192
29 January 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3936710
1 November 2010 Type not recorded
No type recorded · Activities Europe · Activity 3882215
22 March 2010 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3700105
20 February 2010 ACP COI Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3680955
9 July 2009 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3528237
1 May 2009 Ballast Water Examination · ACP COI Oversight · MARPOL Annex I Examination · DAPI Audit · MARPOL Annex V Examination · MTSA/ISPS Verification · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3463655
21 February 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3421413
7 January 2009 Loadline Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3389944
21 July 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2434844
18 April 2005 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2337065
8 February 2005 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2288764
30 November 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2251015
28 November 2004 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2249010
16 July 2004 ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2135711
16 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2156220
14 March 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2024157
11 July 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1843171
7 July 2003 MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1838032
21 March 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1760632
20 March 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1776933
20 March 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1776938
14 June 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1630921
20 February 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1487316

Deficiency record · 48

14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 12 August 2024 Resolved
The attained annual operational CII Shall be documented and verifed against the required annual operational CII to determine operational carbon intensity. Ships crew was unable to produce the vessel's 2023 CII. MARPOL VI Reg 28.6 (Def Code 40AC)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 August 2024
Resolution: Vessel produced current CII post inspection. Vessel has a rating of "A". All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 21 June 2024 Resolved
In all ships, where the distance from sea level to the point of access to, or egress from, the ship exceeds 9 M, and when it is intended to embark and disembark pilots by means of the accommodation ladder in conjunction with a pilot ladder, the ship shall carry such equipment on each side, unless the equipment is capable of being transferred for use on either side. PSCO received a report stating that the starboard side accommodation ladder is inoperable due to a defective manual crank handle pinion shaft. 74SOLAS(20)V/23.3.2 40ac
Action required: 705 - Other - as specified
Due 15 September 2024
Resolved 15 September 2024
Resolution: STBD pilot slant ladder winch assembly reapirs and tested successfully
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 August 2022 Resolved
In a ship which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with the following provisions. PSCO identified oil soaked lagging on main engine and fuel oil heater. Additionally both main engine and fuel oil heater had active leaking and pooling oil.74SOLAS(01)II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2022
Resolution: Class report recieved and found satisfactory. No further action is required.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 April 2021 Resolved
A minimum of two two two-way portable radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried. Ships two-way portable radios were incompatible with ships normal radios so the crew chose not to use the designated fire-fighter's radios.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 11 April 2021 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Forward emergency embarkation station emergency light switch was broken rendering it inoperable and secondary plug was not tied into the emergency source of electrical power.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 April 2021 Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Multiple exterior accommodation doors had broken hinges and unsecured fire hose pass pass through ports.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Lock-out Tag-out procedures were not followed throughout the ship. Multiple tags were found incompletely filled out and motor controls were incorrectly locked-out.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 9 April 2021 Resolved
The Company should periodically evaluate the effectiveness of the safety management system in accordance with procedures established by the company and the audits and possible corrective actions should be carried out in accordance with documented procedures. Maersk Fleet Safety Superintendent was present on board during this inspection and will conduct a planned SMS Audit while ship is en-route to Norfolk. Due to observed conditions on board the ship the superintendent is to provide findings of the audit to this office once complete.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2021
Resolution: Maersk Fleet Safety Superintendent provided internal audit report. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 August 2020 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel is not outfitted with the required number of liferafts.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2020
Resolution: Lloyds accepted as condition of class
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2020 Resolved
The steam regulating valve in the forward engine room bilge has a leak. 74(Solas)14 I/II
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2020 Resolved
A hydraulically actuated fuel valve in the lower forward engine room bilge has a hydraulic oil leak.74(Solas)14 II-2/16.4
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 January 2020 Resolved
The door on the weatherdeck to the steering compartment is not watertight.74(Solas)14 I/II
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 January 2020 Resolved
Found wifi cabling installed with unapproved methods throughout the cable trunk penetrations. Cable penetration in the Cable Duct located on the Upper Deck installed with unapproved methods.74(Solas)14 I/II
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 April 2019 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The #4 engineroom supply damper does not operate. 74 SOLAS (01) II-2/16.9
Action required: 10 - Deficiency Rectified
Resolved 5 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 April 2019 Resolved
Where, in the opinion of the Administration, a fire hazard exists in any machinery space for which no specific provisions for fire-extinguishing appliances are prescribed, there shall be provided in, or adjacent to that space, a means of fire extinction as the Administration shall deem sufficient. There are two 5-gallon AFFF containers with broken seals. The remaining three AFFF containers do not have proper documentation to prove they are not expired. 74 SOLAS (01) II-2/7.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2019
Resolved 9 May 2019
Resolution: Vessels purchsed five new 5-gallon AFFF containers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 5 April 2019 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration and shall ensure thightness can be maintained in any sea condition. Fire damper vent cover in way of starboard lifeboat is missing a dog. Port provision hatch has a seized dog. ICLL 66 I/19(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: New dog installed on fire damper.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 April 2019 Resolved
The means for securing the weathertighness of cargo and other hatchways shall be at least equivalent to requirements of Regs 15 and 16. The forecastle rope scuttle and stern rope scuttle have inoperative dogs. The steering gear compartment hatch cover has a bent dog. ICLL 66 14(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: MI witnessed the proper operation of all dogs on the forward and aft line scuttles.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform to regulations to ensure ship will remain fit to proceed to sea without danger to the ship or persons onboard. The upper navigation light panel is inoperative. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: Vessel installed new navigation light panel on the bridge and the MI witnessed its proper operation and alarms.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 11 February 2018 Resolved
Five (05) flexible hoses in the starboard cargo CO2 space are bent to a degree that the hose diameter is partially restricted. Adjust and inspect hoses and replace if needed to the satisfaction of Class Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that hoses were replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 February 2018 Resolved
Vessel unable to demonstrate operation of OWS due to an excessive ratio of oil to water in tank. Demonstrate proper operation to the satisfaction of Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 11 February 2018
Resolution: Water added to tank allowing for proper demonstration of the OWS to the satisfaction of Class Surveyor. Demonstration occured prior to USCG inspection team departure from the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 11 February 2018 Resolved
#3 Scavenge air impeller and housing is damaged. Repair impeller and housing to the satisfaction of Class Surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that scavenge air impeller and housing were replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 11 February 2018 Resolved
Main engine fuel oil is leaking through the top covers on #1, #6, and #7 cylinders. Repair to the satisfaction of Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 28 March 2018
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 February 2018 Resolved
#1 SW cooling pump variable frequency drive for MDE unwired. Repair to the satisfaction of Class Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 28 March 2018
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 February 2018 Resolved
Cargo hatch #11 stbd side aft corner to 20 feet inboard is missing gasket. Install gasket to the satisfaction of Class Surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that gasket was installed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 11 February 2018 Resolved
Bridge wing fire locker's class A-60 bulkhead is missing insulation in the fwd and aft bulkheads. Insulation shall be carried past the bulkhead 450mm to the satisfaction of Class Surveyor.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds register provided documentation that SFP insulation was installed.
Deck/Cargo › Ballast › Pumps
Issued 11 February 2018 Resolved
Port tunnel ballast controller locked in place using a wood clamp. Repair controller IAW manufacturer's recommendations to the satisfaction of Class Surveyor.
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that vessel installed a new fuse handle.
Electrical › Electric Generation Source (service) › Generator
Issued 5 April 2017 Resolved
Make repairs to the #1 SSDG and prove proper operation.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel chief engineer attested to the repair.
Stability › Watertight Integrity › General
Issued 5 April 2017 Resolved
Make proper adjustments to all quick acting watertight doors through out the ship.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel chief engineer attested to the repair.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 5 April 2017 Resolved
Make all alarm lights operable in the steering room.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel chief engineer attested to the repair.
Electrical › Lighting (service) › Switch
Issued 5 April 2017 Resolved
Provide and install light switches for both walk in reefers.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel Master provided pictures of the new light switches.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 February 2017 Resolved
Clean engine room of oily residues and complete general housekeeping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Rcvd email from master.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 9 January 2017 Resolved
Repair all electrical grounds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Rcvd email from master.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 January 2017 Resolved
Make permanent repairs to fractured handrails in the engine room.
Action required: 705 - Other - as specified
Due 19 March 2017
Resolved 20 April 2017
Resolution: Rcvd email from master.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 January 2017 Resolved
Replace lagging in the engine room that is broken down and/or oil soaked.
Action required: 705 - Other - as specified
Due 19 March 2017
Resolved 20 April 2017
Resolution: Rcvd email from master.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 November 2016 Resolved
Repair the three leaking bunker fuel actuators in the bottom level of the Engine Room, forward, port side, and replace fuel soaked lagging.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 November 2016 Resolved
Remove the lock from the forward storage of the emergency life preservers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 18 November 2016 Resolved
Isolate the 440v ground on the main switchboard and repair or tag out in accordance with ship's procedures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The ground was isolated to refer containers on deck. The refers were de-energized on tagged out in accordance with established procedures.
Construction/Loadline › Hull › Hull Plating
Issued 31 May 2016 Resolved
Prior to departure vessel is to submit a repair proposal for crack in way of the Port #4 HFO tank. Make repairs to the satisfaction of the attending Marine Inspector and Certificate issuing authority.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 8 June 2016
Resolution: Received classification report attesting to the satisfactory permanent repair of the crack in the port side shell plating. The report has been attached to activity #5892857.
Construction/Loadline › Structures › Machinery Space Opening
Issued 6 April 2016 Resolved
Cracking as described in activity narrative.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to ACS (noted as a condition of class)
Construction/Loadline › Structures › Trunk
Issued 6 April 2016 Resolved
Fracture as noted in the activity narrative.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: referred to ACS.
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 6 April 2016 Resolved
Rudder found inoperable on port lifeboat/rescue boat as stated in activity narrative.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to ACS. ACS issued 5 day short term safety equipment certificate.
Fire Fighting › Fire Main › Condition
Issued 6 April 2016 Resolved
Fire main found leaking in port tunnel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to the ACS.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 6 April 2016 Resolved
Aux boiler can only be operated in manual mode. Automation is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to the ACS.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 April 2016 Resolved
Three fire doors found inoperable as noted in the activity narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to the ACS
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 27 January 2016 Resolved
Vessel lost propulison control from the bridge.
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 29 January 2016
Resolution: Repairs carried out. Class attended the vessel and issued Interim certificate.
Navigation › Collision/Grounding Avoidance › Radar
Issued 30 January 2011 Resolved
Vessel requested I/B Dev for faulty primary radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2011
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 November 2004 Resolved
Oil Water Separator (OWS) was found with a bypass leading from the overboard discharge to the bilge holding tank pipe. Bypass was removed and contained a significant amount of oil. USCG Marine Inspectors accompanied by The Administration will conduct an expanded MARPOL examination prior to vessel departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2004
Resolved 29 November 2004
Resolution: USCG Inspectors accompanied by The Administration conducted an extended MARPOL exam. See naritive for details
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 November 2004 Resolved
Vessel is to provide a technicians report attesting to the cleaning, testing, and proper operation of OWS.
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 1 December 2004
Resolution: Vessel appointed technicians to test OWS in Los Angeles on 01 December 2004. A representative of Lloyd''''''''''''''''s Register (class) witness the test and found the OWS satisfactory. The Master of the vessel submitted the a copy of the test report to

Casualty record · 12

1 November 2010Routine · role: Involved in a Marine Casualty · activity 3882215
29 January 2011Routine · role: Involved in a Marine Casualty · activity 3936710
15 February 2011Routine · role: Involved in a Marine Casualty · activity 3946221
21 September 2011Routine · role: Involved in a Marine Casualty · activity 4162056
4 August 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4406729
23 August 2015Routine · role: Involved in a Marine Casualty · activity 5726410
24 August 2015Routine · role: Involved in a Marine Casualty · activity 5807911
2 November 2016Routine · role: Involved in a Marine Casualty · activity 6033997
17 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6788486
3 April 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7169000
11 September 2021Routine · role: Involved in a Marine Casualty · activity 7314241
15 November 2021Routine · role: Involved in a Marine Casualty · activity 7352229
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record