MAURY USCG vessel records
← All vessels

MAERSK IDAHO

Built
1999
Last inspected
24 June 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2026
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9193264
9V7730
Flag
SINGAPORE
Maury page id
psix-1837

Documentation record

Tonnage as PSIX records it50698 - Convention (Subpart B), Gross Ton
29707 - Convention (Subpart B), Net Ton
61986 - Dead Weight, Ton
82327 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 56 inspections, each with its date, unit and type; 45 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 56

24 June 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8412464
14 January 2026 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8297532
11 November 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8266879
31 March 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8102401
17 February 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8080431
5 November 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029636
5 November 2024 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029670
17 September 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8003786
18 August 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7983830
12 August 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7976106
21 June 2024 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7939717
28 February 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7871390
27 October 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7821308
8 September 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7782429
13 February 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7633863
18 August 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7537484
8 August 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528303
6 August 2022 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7525857
16 November 2021 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7352252
15 November 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7352229
17 September 2021 Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 7314248
11 September 2021 Type not recorded
No type recorded · Activities Europe · Activity 7314241
9 April 2021 Administrative Inspection · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7171959
3 April 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7169000
8 March 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7153376
22 October 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7084149
30 August 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7046476
6 July 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7013817
4 June 2020 Administrative Inspection
Administrative · Activities Europe · Activity 6968620
4 February 2020 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6902314
8 January 2020 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6885044
6 January 2020 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6883249
6 December 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6868792
17 August 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6788486
9 May 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6683155
5 April 2019 Annual Inspection · MSP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6655621
13 January 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6609627
24 July 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6488923
6 July 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6495795
26 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6456402
28 March 2018 MTSA/ISPS Verification · Deficiency Check · MSP Annual Oversight · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6374237
11 February 2018 Deficiency Check · MSP Periodic Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6352221
2 February 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6348571
9 September 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6264947
5 April 2017 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6118042
9 January 2017 Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 6067889
9 December 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6055063
16 November 2016 In-Service Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 6042864
2 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6033997
24 October 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6028506
24 September 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6008092
31 May 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5892857
20 April 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5858349
6 April 2016 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847956
27 January 2016 Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 5804141
24 January 2016 Type not recorded
No type recorded · Activities Europe · Activity 5807031

Deficiency record · 45

14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 12 August 2024 Resolved
The attained annual operational CII Shall be documented and verifed against the required annual operational CII to determine operational carbon intensity. Ships crew was unable to produce the vessel's 2023 CII. MARPOL VI Reg 28.6 (Def Code 40AC)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 August 2024
Resolution: Vessel produced current CII post inspection. Vessel has a rating of "A". All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 21 June 2024 Resolved
In all ships, where the distance from sea level to the point of access to, or egress from, the ship exceeds 9 M, and when it is intended to embark and disembark pilots by means of the accommodation ladder in conjunction with a pilot ladder, the ship shall carry such equipment on each side, unless the equipment is capable of being transferred for use on either side. PSCO received a report stating that the starboard side accommodation ladder is inoperable due to a defective manual crank handle pinion shaft. 74SOLAS(20)V/23.3.2 40ac
Action required: 705 - Other - as specified
Due 15 September 2024
Resolved 15 September 2024
Resolution: STBD pilot slant ladder winch assembly reapirs and tested successfully
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 August 2022 Resolved
In a ship which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with the following provisions. PSCO identified oil soaked lagging on main engine and fuel oil heater. Additionally both main engine and fuel oil heater had active leaking and pooling oil.74SOLAS(01)II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2022
Resolution: Class report recieved and found satisfactory. No further action is required.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 April 2021 Resolved
A minimum of two two two-way portable radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried. Ships two-way portable radios were incompatible with ships normal radios so the crew chose not to use the designated fire-fighter's radios.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 11 April 2021 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Forward emergency embarkation station emergency light switch was broken rendering it inoperable and secondary plug was not tied into the emergency source of electrical power.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 April 2021 Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Multiple exterior accommodation doors had broken hinges and unsecured fire hose pass pass through ports.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Lock-out Tag-out procedures were not followed throughout the ship. Multiple tags were found incompletely filled out and motor controls were incorrectly locked-out.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 25 April 2021
Resolution: Received satisfactory Lloyd's report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 9 April 2021 Resolved
The Company should periodically evaluate the effectiveness of the safety management system in accordance with procedures established by the company and the audits and possible corrective actions should be carried out in accordance with documented procedures. Maersk Fleet Safety Superintendent was present on board during this inspection and will conduct a planned SMS Audit while ship is en-route to Norfolk. Due to observed conditions on board the ship the superintendent is to provide findings of the audit to this office once complete.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2021
Resolution: Maersk Fleet Safety Superintendent provided internal audit report. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 August 2020 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel is not outfitted with the required number of liferafts.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2020
Resolution: Lloyds accepted as condition of class
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2020 Resolved
The steam regulating valve in the forward engine room bilge has a leak. 74(Solas)14 I/II
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2020 Resolved
A hydraulically actuated fuel valve in the lower forward engine room bilge has a hydraulic oil leak.74(Solas)14 II-2/16.4
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 January 2020 Resolved
The door on the weatherdeck to the steering compartment is not watertight.74(Solas)14 I/II
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 January 2020 Resolved
Found wifi cabling installed with unapproved methods throughout the cable trunk penetrations. Cable penetration in the Cable Duct located on the Upper Deck installed with unapproved methods.74(Solas)14 I/II
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2020
Resolved 4 February 2020
Resolution: Cleared via Lloyds Class report #2061350
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 April 2019 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The #4 engineroom supply damper does not operate. 74 SOLAS (01) II-2/16.9
Action required: 10 - Deficiency Rectified
Resolved 5 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 April 2019 Resolved
Where, in the opinion of the Administration, a fire hazard exists in any machinery space for which no specific provisions for fire-extinguishing appliances are prescribed, there shall be provided in, or adjacent to that space, a means of fire extinction as the Administration shall deem sufficient. There are two 5-gallon AFFF containers with broken seals. The remaining three AFFF containers do not have proper documentation to prove they are not expired. 74 SOLAS (01) II-2/7.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2019
Resolved 9 May 2019
Resolution: Vessels purchsed five new 5-gallon AFFF containers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 5 April 2019 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration and shall ensure thightness can be maintained in any sea condition. Fire damper vent cover in way of starboard lifeboat is missing a dog. Port provision hatch has a seized dog. ICLL 66 I/19(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: New dog installed on fire damper.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 April 2019 Resolved
The means for securing the weathertighness of cargo and other hatchways shall be at least equivalent to requirements of Regs 15 and 16. The forecastle rope scuttle and stern rope scuttle have inoperative dogs. The steering gear compartment hatch cover has a bent dog. ICLL 66 14(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: MI witnessed the proper operation of all dogs on the forward and aft line scuttles.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform to regulations to ensure ship will remain fit to proceed to sea without danger to the ship or persons onboard. The upper navigation light panel is inoperative. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: Vessel installed new navigation light panel on the bridge and the MI witnessed its proper operation and alarms.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 11 February 2018 Resolved
Five (05) flexible hoses in the starboard cargo CO2 space are bent to a degree that the hose diameter is partially restricted. Adjust and inspect hoses and replace if needed to the satisfaction of Class Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that hoses were replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 February 2018 Resolved
Vessel unable to demonstrate operation of OWS due to an excessive ratio of oil to water in tank. Demonstrate proper operation to the satisfaction of Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 11 February 2018
Resolution: Water added to tank allowing for proper demonstration of the OWS to the satisfaction of Class Surveyor. Demonstration occured prior to USCG inspection team departure from the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 11 February 2018 Resolved
#3 Scavenge air impeller and housing is damaged. Repair impeller and housing to the satisfaction of Class Surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that scavenge air impeller and housing were replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 11 February 2018 Resolved
Main engine fuel oil is leaking through the top covers on #1, #6, and #7 cylinders. Repair to the satisfaction of Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 28 March 2018
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 February 2018 Resolved
#1 SW cooling pump variable frequency drive for MDE unwired. Repair to the satisfaction of Class Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 28 March 2018
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 February 2018 Resolved
Cargo hatch #11 stbd side aft corner to 20 feet inboard is missing gasket. Install gasket to the satisfaction of Class Surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that gasket was installed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 11 February 2018 Resolved
Bridge wing fire locker's class A-60 bulkhead is missing insulation in the fwd and aft bulkheads. Insulation shall be carried past the bulkhead 450mm to the satisfaction of Class Surveyor.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds register provided documentation that SFP insulation was installed.
Deck/Cargo › Ballast › Pumps
Issued 11 February 2018 Resolved
Port tunnel ballast controller locked in place using a wood clamp. Repair controller IAW manufacturer's recommendations to the satisfaction of Class Surveyor.
Action required: 705 - Other - as specified
Due 11 March 2018
Resolved 23 February 2018
Resolution: Lloyds Register provided documentation that vessel installed a new fuse handle.
Electrical › Electric Generation Source (service) › Generator
Issued 5 April 2017 Resolved
Make repairs to the #1 SSDG and prove proper operation.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel chief engineer attested to the repair.
Stability › Watertight Integrity › General
Issued 5 April 2017 Resolved
Make proper adjustments to all quick acting watertight doors through out the ship.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel chief engineer attested to the repair.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 5 April 2017 Resolved
Make all alarm lights operable in the steering room.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel chief engineer attested to the repair.
Electrical › Lighting (service) › Switch
Issued 5 April 2017 Resolved
Provide and install light switches for both walk in reefers.
Action required: 705 - Other - as specified
Due 22 April 2017
Resolved 21 April 2017
Resolution: Vessel Master provided pictures of the new light switches.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 February 2017 Resolved
Clean engine room of oily residues and complete general housekeeping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Rcvd email from master.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 9 January 2017 Resolved
Repair all electrical grounds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Rcvd email from master.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 January 2017 Resolved
Make permanent repairs to fractured handrails in the engine room.
Action required: 705 - Other - as specified
Due 19 March 2017
Resolved 20 April 2017
Resolution: Rcvd email from master.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 January 2017 Resolved
Replace lagging in the engine room that is broken down and/or oil soaked.
Action required: 705 - Other - as specified
Due 19 March 2017
Resolved 20 April 2017
Resolution: Rcvd email from master.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 November 2016 Resolved
Repair the three leaking bunker fuel actuators in the bottom level of the Engine Room, forward, port side, and replace fuel soaked lagging.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 November 2016 Resolved
Remove the lock from the forward storage of the emergency life preservers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 18 November 2016 Resolved
Isolate the 440v ground on the main switchboard and repair or tag out in accordance with ship's procedures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The ground was isolated to refer containers on deck. The refers were de-energized on tagged out in accordance with established procedures.
Construction/Loadline › Hull › Hull Plating
Issued 31 May 2016 Resolved
Prior to departure vessel is to submit a repair proposal for crack in way of the Port #4 HFO tank. Make repairs to the satisfaction of the attending Marine Inspector and Certificate issuing authority.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 8 June 2016
Resolution: Received classification report attesting to the satisfactory permanent repair of the crack in the port side shell plating. The report has been attached to activity #5892857.
Construction/Loadline › Structures › Machinery Space Opening
Issued 6 April 2016 Resolved
Cracking as described in activity narrative.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to ACS (noted as a condition of class)
Construction/Loadline › Structures › Trunk
Issued 6 April 2016 Resolved
Fracture as noted in the activity narrative.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: referred to ACS.
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 6 April 2016 Resolved
Rudder found inoperable on port lifeboat/rescue boat as stated in activity narrative.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to ACS. ACS issued 5 day short term safety equipment certificate.
Fire Fighting › Fire Main › Condition
Issued 6 April 2016 Resolved
Fire main found leaking in port tunnel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to the ACS.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 6 April 2016 Resolved
Aux boiler can only be operated in manual mode. Automation is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to the ACS.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 April 2016 Resolved
Three fire doors found inoperable as noted in the activity narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Referred to the ACS
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 27 January 2016 Resolved
Vessel lost propulison control from the bridge.
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 29 January 2016
Resolution: Repairs carried out. Class attended the vessel and issued Interim certificate.

Ownership record