Records from 2005 to 2012. Most recent: inspection, 31 January 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 March 2009
Resolved
Fixed FE-241 system servicing is out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 13 March 2009
Resolved
Replace missing bolts and tighten loose bolts on engine mounts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 March 2009
Resolved
Properly seal outlet box FWD of stbd MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Engineering › Sea-water System (primary cooling) › Valve
Issued 13 March 2009
Resolved
Replace valve handle on STBD side engine valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 March 2009
Resolved
Provide blanks for empty fuse panel slots.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 March 2009
Resolved
Provide machinery guards for both engines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Construction/Loadline › Penetrations › Weld
Issued 13 March 2009
Resolved
Make 04 repairs to port side railings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Construction/Loadline › Hull › Transverse Frame
Issued 13 March 2009
Resolved
Repair cracked weld in FWD compartment portside 1st transverse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 13 March 2009
Resolved
Replace both strut cutlass bearings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 March 2009
Resolved
Repair 05 cracks in topside railing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 8 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2009
Resolved
Remove wiring penetrating collision bulkhead and permanently seal thru bulkhead hole.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 September 2008
Resolved
Update or Replace first aid kit.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 September 2008
Resolved
Provide tide and current publications
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 September 2008
Resolved
Provide valid registration for EPIRB
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 September 2008
Resolved
Provide new hydrostatic release for epirb
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 September 2008
Resolved
Provide new labeling for PFD storage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 September 2008
Resolved
Provide stenciling for topside lifejackets and QTY.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 10 September 2008
Resolved
Properly connect engine crankcase hoses.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 September 2008
Resolved
Provide metal clamps for machinery space wiring every 24 inches.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 September 2008
Resolved
Replace/repair stbd side fuel shutoff handle.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 September 2008
Resolved
Seperate stowage areas for childs/adult PFD's.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Stability › Watertight Integrity › General
Issued 10 September 2008
Resolved
Seal overhead thru hole on port side engine room.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 10 September 2008
Resolved
Remove flex hose and replace with hard pipe for fuel return line.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 10 September 2008
Resolved
Properly install wiring for aft lighting.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 10 September 2008
Resolved
Provide spacers for buoyant apparatus.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 April 2007
Resolved
provide service report for fixed fire fighting system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Provided report.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 April 2007
Resolved
remove excess fuel from bilges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Cleaned all machinery spaces while vsl was in drydock.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 3 April 2007
Resolved
prove proper operation of buoyant strobes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Buoyant strobes sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2007
Resolved
provide full encapsulating connectors for all wiring and no wirenuts
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Installed wire nuts.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 April 2007
Resolved
prove proper operation of engine room high water alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: alarm test sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 April 2007
Resolved
Perform satisfactory MOB drill.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2007
Resolution: MOB drill performed satisfactorily w/ permanent crew.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 April 2007
Resolved
Permanently secure bilge pumps.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2007
Resolution: Bilge pumps permanently secured.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 3 April 2007
Resolved
Vessel is required to install an emergency escape hatch in passenger salon/accommodation space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 July 2007
Resolution: Emergency escape hatch has been installed satisfactory.
Lifesaving › Buoyant Apparatus › Marking
Issued 1 August 2006
Resolved
Paint all buoyant apparatus paddles int'l orange
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: Paddles painted.
Communications › Alarms/Indicators › Speed/Distance Indicator
Issued 1 August 2006
Resolved
Provide proper operation of all machinery gauges
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: Gauges working properly.
Communications › Visual Communication › Signalling Lamp
Issued 1 August 2006
Resolved
Provide two functional portable lanterns
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: Purchased 2 flashlights.
Documentation › Logs/Records › Drug Test Records
Issued 1 August 2006
Resolved
Provide proof of enrollment in drug consortium for all crew
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: All crew enrolled, cards shown.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 1 August 2006
Resolved
Provide metal support brackets every 24" for all machinery space wiring
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2007
Resolution: Installed brackets.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 1 August 2006
Resolved
Ensure Propulsion machinery is operating safely and at normal performance level
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2007
Resolution: Performed satisfactory sea trial.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 August 2006
Resolved
Prove Proper operation of ssb radio
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: SSB operational.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 1 August 2006
Resolved
Prove proper operation of flying bridge throttles
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2007
Resolution: Completed satisfactory sea trial.
Construction/Loadline › Hull › Bottom Plating
Issued 24 February 2006
Resolved
Shell plate is cracked aft of port strut (stress crack)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 February 2006
Resolution: Crack was properly prepped and repaired.
Engineering › Fuel Oil Service System › Tank
Issued 31 October 2005
Resolved
Multiple cracked welds on internal stiffeners and small seam crack on exterior.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Welds were properly prepped and repaired. Fuel tank was leak-down tested at 5 psi for 30 min with no loss of pressure.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 26 April 2005
Resolved
One engine mount on each engine was cracked
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 2 April 2007
Resolution: Repaired crack
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 April 2005
Resolved
Repair all holes/penetrations in watertight bulkheads
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 2 April 2007
Resolution: Sealed all thru holes.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2005
Resolved
Electric automatic bilge pumps must be of an approved type (UL)
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 5 June 2007
Resolution: Installed sat bilge pumps.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 26 April 2005
Resolved
Provide data sheet for FRP-type material that is to be used as interior panelling.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: O/O provided manufactures data sheet showing the paneling met the requirements for flame spread and smoke production.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 26 April 2005
Resolved
O/O to provide the following arrangement plans: inboard profile, electrical diagram, through-hull arrangement and machinery arrangement
Condition: Unknown
Due 1 June 2006
Resolved 24 February 2006
Resolution: O/O provided all required plans
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2005
Resolved
Remove all through hull valves and make ready for inspection
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: All valves were inspected and found sat.
Construction/Loadline › Hull › Bottom Plating
Issued 26 April 2005
Resolved
Repair 04 pitted areas on bottom plating (marked for identificaiton)
Condition: Improper Installation
Due 1 June 2006
Resolved 24 February 2006
Resolution: Pitting was prepped and clad welded to repair.
Construction/Loadline › Hull › Bottom Plating
Issued 26 April 2005
Resolved
Repair crack IVO stbd rudder post pocket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Crack was prepped and properly repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 26 April 2005
Resolved
Repair crack IVO port aft shaft strut
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Crack was prepped and properly repaired.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 26 April 2005
Resolved
Replace all stern tube bearings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: All bearings were replaced.
Engineering › Steering Gear System › Rudder Bearing
Issued 26 April 2005
Resolved
Replace both rudder bearings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Both bearings were replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 April 2005
Resolved
Install and label emergency fuel shut off valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2005
Resolved
Install metal supports on electrical wiring every 24"
Condition: Placed in Improper Service
Due 1 June 2006
Resolved 2 April 2007
Resolution: Def removed due to being on another activity.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 26 April 2005
Resolved
Repair both propellers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Both props were repaired and refinished.
Engineering › Fuel Oil Service System › Tank
Issued 26 April 2005
Resolved
Repair fuel oil leak in forward fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Crack was prepped and properly welded.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 April 2005
Resolved
Provide report for shaft alignment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: O/O provided shaft runout report from shop.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 26 April 2005
Resolved
Provide documentation of certification of fuel tanks.
Condition: Unknown
Due 1 June 2006
Resolved 24 February 2006
Resolution: MSC approved plans of exsisting fuel tanks.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2005
Resolved
Prove proper operation of engine-driven bilge pump/manifold system.
Condition: Improper Installation
Due 1 June 2006
Resolved 5 June 2007
Resolution: Performed sat test.
Engineering › Steering Gear System › Fastener
Issued 26 April 2005
Resolved
Provide jam-nuts for bolts on steering gear tie-rod.
Condition: Improper Installation
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed jam nuts.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 April 2005
Resolved
Replace raw water intake hose on generator.
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed new hose.
Engineering › Steering Gear System › Hydraulic Hose
Issued 26 April 2005
Resolved
Properly support hydraulic lines for steering gear in aft compartment.
Condition: Improper Installation
Due 1 June 2006
Resolved 2 April 2007
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 April 2005
Resolved
Weld cracks in con. tower railing (both corners of nav. station)
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 2 April 2007
Resolution: Repaired cracks.
Engineering › Fuel Oil Service System › Filter
Issued 26 April 2005
Resolved
Provide flame cup on fuel strainer on starboard MDE>
Condition: Improper Installation
Due 1 June 2006
Resolved 5 June 2007
Resolution: Installed flame cup
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 April 2005
Resolved
Provide battery covers for all batteries.
Condition: Unknown
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed battery covers.