MAURY USCG vessel records Sign in
← All vessels

LADY REMINGTON I

LADY REMINGTON I is a 1973 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2005, most recently in January 2012, along with 67 deficiencies.

Records from 2005 to 2012. Most recent: inspection, 31 January 2012.

Built
1973
Last inspected
31 January 2012
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF4988
183704
Flag
UNITED STATES
367123530, 367458070 (licence lapsed)
Maury page id
psix-183704

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2005–2012)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.5 ft × 15.0 ft × 7.2 ft
Registered tonnagegross 33 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT, INC. · LOREAUVILLE, LA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGULF SHORES, AL
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF4988MMSI 367458070 · expired · compulsorily equipped · granted 19 June 2010, cancelled 22 August 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDD3075MMSI 367123530 · expired · compulsorily equipped · granted 23 June 2006, cancelled 27 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

31 January 2012 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 4235273
13 March 2009 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3434028
10 September 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3321992
3 April 2007 Initial Certification
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2900587
1 August 2006 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2732394
19 April 2006 Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2628471
26 April 2005 Initial Certification · Construction Oversight
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2628183
23 January 2005 Type not recorded
No type recorded · Station Brunswick · USCG Southeast District (CGD-SE) · Activity 2279555

Deficiency record · 67

Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 March 2009 Resolved
Fixed FE-241 system servicing is out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 13 March 2009 Resolved
Replace missing bolts and tighten loose bolts on engine mounts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 March 2009 Resolved
Properly seal outlet box FWD of stbd MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Engineering › Sea-water System (primary cooling) › Valve
Issued 13 March 2009 Resolved
Replace valve handle on STBD side engine valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 March 2009 Resolved
Provide blanks for empty fuse panel slots.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 March 2009 Resolved
Provide machinery guards for both engines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Construction/Loadline › Penetrations › Weld
Issued 13 March 2009 Resolved
Make 04 repairs to port side railings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Construction/Loadline › Hull › Transverse Frame
Issued 13 March 2009 Resolved
Repair cracked weld in FWD compartment portside 1st transverse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 13 March 2009 Resolved
Replace both strut cutlass bearings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 March 2009 Resolved
Repair 05 cracks in topside railing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 8 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2009 Resolved
Remove wiring penetrating collision bulkhead and permanently seal thru bulkhead hole.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 September 2008 Resolved
Update or Replace first aid kit.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 September 2008 Resolved
Provide tide and current publications
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 September 2008 Resolved
Provide valid registration for EPIRB
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 September 2008 Resolved
Provide new hydrostatic release for epirb
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 September 2008 Resolved
Provide new labeling for PFD storage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 September 2008 Resolved
Provide stenciling for topside lifejackets and QTY.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 10 September 2008 Resolved
Properly connect engine crankcase hoses.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 September 2008 Resolved
Provide metal clamps for machinery space wiring every 24 inches.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 September 2008 Resolved
Replace/repair stbd side fuel shutoff handle.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 September 2008 Resolved
Seperate stowage areas for childs/adult PFD's.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Stability › Watertight Integrity › General
Issued 10 September 2008 Resolved
Seal overhead thru hole on port side engine room.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 10 September 2008 Resolved
Remove flex hose and replace with hard pipe for fuel return line.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 10 September 2008 Resolved
Properly install wiring for aft lighting.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 10 September 2008 Resolved
Provide spacers for buoyant apparatus.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 April 2007 Resolved
provide service report for fixed fire fighting system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Provided report.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 April 2007 Resolved
remove excess fuel from bilges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Cleaned all machinery spaces while vsl was in drydock.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 3 April 2007 Resolved
prove proper operation of buoyant strobes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Buoyant strobes sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2007 Resolved
provide full encapsulating connectors for all wiring and no wirenuts
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Installed wire nuts.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 April 2007 Resolved
prove proper operation of engine room high water alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: alarm test sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 April 2007 Resolved
Perform satisfactory MOB drill.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2007
Resolution: MOB drill performed satisfactorily w/ permanent crew.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 April 2007 Resolved
Permanently secure bilge pumps.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2007
Resolution: Bilge pumps permanently secured.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 3 April 2007 Resolved
Vessel is required to install an emergency escape hatch in passenger salon/accommodation space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 July 2007
Resolution: Emergency escape hatch has been installed satisfactory.
Lifesaving › Buoyant Apparatus › Marking
Issued 1 August 2006 Resolved
Paint all buoyant apparatus paddles int'l orange
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: Paddles painted.
Communications › Alarms/Indicators › Speed/Distance Indicator
Issued 1 August 2006 Resolved
Provide proper operation of all machinery gauges
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: Gauges working properly.
Communications › Visual Communication › Signalling Lamp
Issued 1 August 2006 Resolved
Provide two functional portable lanterns
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: Purchased 2 flashlights.
Documentation › Logs/Records › Drug Test Records
Issued 1 August 2006 Resolved
Provide proof of enrollment in drug consortium for all crew
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: All crew enrolled, cards shown.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 1 August 2006 Resolved
Provide metal support brackets every 24" for all machinery space wiring
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2007
Resolution: Installed brackets.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 1 August 2006 Resolved
Ensure Propulsion machinery is operating safely and at normal performance level
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2007
Resolution: Performed satisfactory sea trial.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 August 2006 Resolved
Prove Proper operation of ssb radio
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Resolution: SSB operational.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 1 August 2006 Resolved
Prove proper operation of flying bridge throttles
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2007
Resolution: Completed satisfactory sea trial.
Construction/Loadline › Hull › Bottom Plating
Issued 24 February 2006 Resolved
Shell plate is cracked aft of port strut (stress crack)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 February 2006
Resolution: Crack was properly prepped and repaired.
Engineering › Fuel Oil Service System › Tank
Issued 31 October 2005 Resolved
Multiple cracked welds on internal stiffeners and small seam crack on exterior.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Welds were properly prepped and repaired. Fuel tank was leak-down tested at 5 psi for 30 min with no loss of pressure.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 26 April 2005 Resolved
One engine mount on each engine was cracked
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 2 April 2007
Resolution: Repaired crack
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 April 2005 Resolved
Repair all holes/penetrations in watertight bulkheads
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 2 April 2007
Resolution: Sealed all thru holes.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2005 Resolved
Electric automatic bilge pumps must be of an approved type (UL)
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 5 June 2007
Resolution: Installed sat bilge pumps.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 26 April 2005 Resolved
Provide data sheet for FRP-type material that is to be used as interior panelling.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: O/O provided manufactures data sheet showing the paneling met the requirements for flame spread and smoke production.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 26 April 2005 Resolved
O/O to provide the following arrangement plans: inboard profile, electrical diagram, through-hull arrangement and machinery arrangement
Condition: Unknown
Due 1 June 2006
Resolved 24 February 2006
Resolution: O/O provided all required plans
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2005 Resolved
Remove all through hull valves and make ready for inspection
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: All valves were inspected and found sat.
Construction/Loadline › Hull › Bottom Plating
Issued 26 April 2005 Resolved
Repair 04 pitted areas on bottom plating (marked for identificaiton)
Condition: Improper Installation
Due 1 June 2006
Resolved 24 February 2006
Resolution: Pitting was prepped and clad welded to repair.
Construction/Loadline › Hull › Bottom Plating
Issued 26 April 2005 Resolved
Repair crack IVO stbd rudder post pocket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Crack was prepped and properly repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 26 April 2005 Resolved
Repair crack IVO port aft shaft strut
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Crack was prepped and properly repaired.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 26 April 2005 Resolved
Replace all stern tube bearings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: All bearings were replaced.
Engineering › Steering Gear System › Rudder Bearing
Issued 26 April 2005 Resolved
Replace both rudder bearings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Both bearings were replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 April 2005 Resolved
Install and label emergency fuel shut off valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2005 Resolved
Install metal supports on electrical wiring every 24"
Condition: Placed in Improper Service
Due 1 June 2006
Resolved 2 April 2007
Resolution: Def removed due to being on another activity.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 26 April 2005 Resolved
Repair both propellers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Both props were repaired and refinished.
Engineering › Fuel Oil Service System › Tank
Issued 26 April 2005 Resolved
Repair fuel oil leak in forward fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: Crack was prepped and properly welded.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 April 2005 Resolved
Provide report for shaft alignment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 24 February 2006
Resolution: O/O provided shaft runout report from shop.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 26 April 2005 Resolved
Provide documentation of certification of fuel tanks.
Condition: Unknown
Due 1 June 2006
Resolved 24 February 2006
Resolution: MSC approved plans of exsisting fuel tanks.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2005 Resolved
Prove proper operation of engine-driven bilge pump/manifold system.
Condition: Improper Installation
Due 1 June 2006
Resolved 5 June 2007
Resolution: Performed sat test.
Engineering › Steering Gear System › Fastener
Issued 26 April 2005 Resolved
Provide jam-nuts for bolts on steering gear tie-rod.
Condition: Improper Installation
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed jam nuts.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 April 2005 Resolved
Replace raw water intake hose on generator.
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed new hose.
Engineering › Steering Gear System › Hydraulic Hose
Issued 26 April 2005 Resolved
Properly support hydraulic lines for steering gear in aft compartment.
Condition: Improper Installation
Due 1 June 2006
Resolved 2 April 2007
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 April 2005 Resolved
Weld cracks in con. tower railing (both corners of nav. station)
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 2 April 2007
Resolution: Repaired cracks.
Engineering › Fuel Oil Service System › Filter
Issued 26 April 2005 Resolved
Provide flame cup on fuel strainer on starboard MDE>
Condition: Improper Installation
Due 1 June 2006
Resolved 5 June 2007
Resolution: Installed flame cup
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 April 2005 Resolved
Provide battery covers for all batteries.
Condition: Unknown
Due 1 June 2006
Resolved 2 April 2007
Resolution: Installed battery covers.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.