A. C. BROWN ELEVATOR

A. C. BROWN ELEVATOR is a 1980 offshore supply vessel. The Coast Guard has recorded 27 inspections since 1995, most recently in May 2019, along with 51 deficiencies and 1 operational control.

Records from 1995 to 2019. Most recent: inspection, 23 May 2019.

Built
1980
Last inspected
23 May 2019
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

----------
183720
Flag
UNITED STATES
—
Maury page id
psix-183720

Inspections, by type

…with no type recorded2
Years with a record 20 calendar years (1995–2019)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 4.4 ft
Registered tonnagegross 90 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS, INC · CAERNARVON, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

23 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6691330
6 May 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6677726
13 June 2018 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6442943
29 March 2017 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6113717
21 March 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6108597
1 April 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5844994
28 March 2014 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4824236
24 May 2012 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4319602
11 March 2009 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3431433
31 March 2008 Internal Structural Exam · Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3201656
10 May 2007 Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2927250
1 March 2006 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2593841
12 January 2005 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2272653
23 March 2004 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2029473
14 January 2003 Annual Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1727174
10 May 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462224
23 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771710
18 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 196932
10 January 2000 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424852
15 April 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395165
10 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465364
10 April 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424372
17 June 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439753
7 April 1995 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425566
30 March 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 836763
31 January 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 831124
27 January 1995 Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363178

Deficiency record · 51

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 May 2019 Resolved
EPIRB not stowed in a float free location. Current location had 2 ft overhand that could impede float free. Stow in float free location. 46 CFR 160.64
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 24 May 2019
Resolution: EPIRB permanently stowed on wheel house. Nothing will impede it from being float free.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 23 May 2019 Resolved
Knotted manrope not stowed in a manner for immediate use. Stow manrope for immediate use in the event of an emergency. 46 CFR 133.110
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 May 2019
Resolution: Manrope stowed on bow for immediate use.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019 Resolved
Port side crane has broken boom angle indicator. Fix or repair boom angle indicator. 46 CFR 109.525
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 May 2019
Resolution: New boom angle indicator installed on crane.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2019 Resolved
The wire connections to the bilge alarm was exposed. Secure wire connection with a permanent type connection with no exposed wires. 46 CFR 183.01-15
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 May 2019
Resolution: Permanent type connection used for wire connection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2019 Resolved
Starboard side navigation light wiring had an exposed junction box on the weather deck. Make junction box with wire connections weather-tight. 46 CFR 183.05-35
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 May 2019
Resolution: Junction box replaced with weathertight junction box.
Construction/Loadline › Hull › Hull Plating
Issued 13 June 2018 Resolved
Deck plate around hatch needs to be cropped and renewed
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2018
Resolution: Deck plate cropped to good metal. Insert completed. Dye pen test showed two leaks. Welds were gouged and rewelded and tested satisfactory.
Lifesaving › Lifefloat › Retroreflective Material
Issued 21 March 2017 Resolved
Provide retro reflective tape for life float in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2017
Resolved 29 March 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 March 2017 Resolved
Renew wasted frames located on port rudder post, bottom longitudinal, and frame located STBD side main propulsion, bottom longitudinal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2017
Resolved 29 March 2017
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 March 2017 Resolved
Provide legible emergency exit labels on escape exits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 29 March 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 March 2017 Resolved
Provide labeling for junction box located on stbd side fwd engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 29 March 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2017 Resolved
Provide personnel protection from rotating machinery fwd of main engine on PTO
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 29 March 2017
Engineering › Steering Gear System › Linkage
Issued 21 March 2017 Resolved
Provide serviceable steering linkage and provide satisfactory operational test in presence of marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2017
Resolved 29 March 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 March 2017 Resolved
Provide service to port main propulsion oil leak near exhaust to eliminate fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2017
Resolved 29 March 2017
Fire Fighting › Means of Escape › Blocked
Issued 21 March 2017 Resolved
Make engine room escape hatches operable from inside space in accordance with vessel operational manual.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2017
Resolved 29 March 2017
Construction/Loadline › Hull › Side Shell
Issued 1 April 2016 Resolved
Found a hole in the side shell aft of the forward port escape hatch. C/R to good metal and perform NDT to the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2016
Resolved 24 May 2016
Resolution: Side shell insert completed and NDT witnessed by a USCG Marine Inspector.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 1 April 2016 Resolved
Tilt alarms not operational. Identify/Correct issue and prove proper operation to the satisfaction of the attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2016
Resolved 24 May 2016
Resolution: Witnessed tilt alarms.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 1 April 2016 Resolved
Ventilation cover AFT house does not close of air to machinery space. Correct issue to satisfaction of attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2016
Resolved 16 June 2016
Resolution: Cover repaired and closes.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 April 2016 Resolved
Vessel only had 1 VHF radio. Vessel restricted to within 20NM unil addtional radio provided and confirmed by attending USCG MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 16 June 2016
Resolution: Attempted to call FCC to verify requirement with negative results. The applicability of the regulations is a passenger vessel carrying more than 6 passengers for hire and greater than 65 ft. Vessel is less than 65 ft
Lifesaving › Hand Flares › Quantity
Issued 28 March 2014 Resolved
Vessel required 6 Red and 6 orange smoke. Vessel only had 6 Red and 3 Orange flares onboard.
Action required: 705 - Other - as specified
Resolved 28 March 2014
Resolution: The proper number Distress signals place onboard.
Electrical › Electric Supply System (service) › Cable
Issued 28 March 2014 Resolved
Numerous dead ended and unsupported wires.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2014
Engineering › Bilge Water Management System › Piping
Issued 28 March 2014 Resolved
Bilge system not operable cracked flexible piping installed in the bilge system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2014
Resolution: New bilge pump & manifold installed; tested sat.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 28 March 2014 Resolved
Vessel operations manual not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2014
Resolution: Operations manual placed onboard.
Construction/Loadline › Structures › Deck Plating
Issued 28 March 2014 Resolved
A large section of deck was cut out and replaced above the Port engine due to water entering the engine room, without any notification to the Coast Guard as required by 46 CFR 176.700. NDT required for the repaired area in the presence of a USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2014
Resolution: Witnessed sat dye pen test on all inserts.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2014 Resolved
Navigation Lights not all operational and light stand on the port side was hit by the crane and bent.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2014
Resolution: Port side nav light was repaired and working.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 28 March 2014 Resolved
STBD crane would not hold a load for load test at maximum boom angle. Provide original crane structural and engineering drawings including a professional assessment for safe working loads for boom angles.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2014
Resolution: Witnessed sat 60 month crane test on STBD crane. See narrative for details
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 March 2014 Resolved
Attended vessel for an annual inspection, vessel was not ready for inspection. Noted failed inspection. An Annual inspection needs to be conducted prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2014
Resolution: Inspection complete.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 May 2012 Resolved
110 volt electrical outlet box next to the dryer was missing wx covers. Install wx covers or remove box.
Condition: Improper/Lack of Maintenance
Due 31 May 2012
Resolved 1 June 2012
Resolution: Vsl moved 110 volt electrical outlet box away from wx and installed wx cover.
Electrical › Electric Generation Source (service) › Generator
Issued 24 May 2012 Resolved
Generator windings were very dirty/oily. Clean generator windings and vents.
Condition: Improper/Lack of Maintenance
Due 31 May 2012
Resolved 1 June 2012
Resolution: Vessel installed newly serviced genset which had clean generator windings.
Engineering › Fuel Oil Service System › Valve
Issued 24 May 2012 Resolved
F/o valve handle missing. Install handle.
Condition: Improper/Lack of Maintenance
Due 31 May 2012
Resolved 1 June 2012
Resolution: Vsl installed new valve handle.
Engineering › Fuel Oil Service System › Piping
Issued 24 May 2012 Resolved
Port and stbd f/o return piping was severely chaffed in numerous areas. Install new piping with proper supports.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2012
Resolution: Vessel crew separated f/o lines which were chaffing. Upon further inspection, found f/o piping to be satisfactory. Vessel installed more f/o piping supports and separated piping so no areas were chaffing.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 May 2012 Resolved
Vsl had hoses on the f/o fill pipe for the storage tanks. There was no electrical bonding between the hoses on the fill pipe. Install grounding wire between each section of hose on the f/o fill pipe.
Condition: Improper/Lack of Maintenance
Due 31 May 2012
Resolved 1 June 2012
Resolution: Pipe thought was the f/o fill pipe as per the deckhand, turned out to be the vent pipe.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 May 2012 Resolved
Dryer junction box was not mounted and not labeled. Mount junction box and label.
Condition: Improper/Lack of Maintenance
Due 31 May 2012
Resolved 1 June 2012
Resolution: Junction box that was not labeled was found to be the breaker for the fire pump. Box was mounted and labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2012 Resolved
Port and stbd main engines had various exposed wires throughout both main engines.
Condition: Improper/Lack of Maintenance
Due 31 May 2012
Resolved 1 June 2012
Resolution: Vsl corrected all wiring for the engines.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 24 May 2012 Resolved
Stbd main engine had large amounts of oil leaking down the engine dripping onto the starter. Repair oil leaks.
Condition: Improper/Lack of Maintenance
Due 31 May 2012
Resolved 1 June 2012
Resolution: Oil was coming from the crankcase breather on top of the valve cover. Vsl installed hose to divert the oily/air away from the starter.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 24 May 2012 Resolved
Rescue boat engine would not stay running during the man ovbd drill. Repair engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2012
Resolution: Vsl had rescue boat engine tuned up. Ran rescue boat, sat.
Operations/Management › Drills/Instruction › Fire
Issued 24 May 2012 Resolved
Drills were not routinely logged.
Condition: Improper/Lack of Maintenance
Due 24 June 2012
Resolved 28 June 2012
Resolution: Vessel sent email with a copy of their newly developed drill log.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 May 2012 Resolved
Drills were not routinely logged.
Condition: Improper/Lack of Maintenance
Due 24 June 2012
Resolved 28 June 2012
Resolution: Vessel sent email with a copy of their newly developed drill log.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 May 2012 Resolved
Drills were not routinely logged.
Condition: Improper/Lack of Maintenance
Due 24 June 2012
Resolved 28 June 2012
Resolution: Vessel sent email with a copy of their newly developed drill log.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 March 2009 Resolved
Secure/mount e-light in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Lifesaving › Lifefloat › Float-free Link
Issued 11 March 2009 Resolved
Install a proper weak link on vsl's life float.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 11 March 2009 Resolved
Provide an emergency broadcast placard at the operating station near the VHF radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Fire Fighting › Nozzles › Condition
Issued 11 March 2009 Resolved
Replace one firefighting nozzel on stbd fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 March 2009 Resolved
Provide cross members for stove sea rails.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 11 March 2009 Resolved
Repair/renew oil leaks on vsl's generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 May 2007 Resolved
Provide
Due 11 June 2007
Resolved 16 May 2007
Navigation › Piloting/Steering › Marine Charts
Issued 10 May 2007 Resolved
Provide updated charts.
Due 11 June 2007
Resolved 16 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2007 Resolved
Paint screens matte black.
Due 11 June 2007
Resolved 16 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 May 2007 Resolved
Visual and Audible Alarm required at operating station.
Due 11 June 2007
Resolved 16 May 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 May 2007 Resolved
Vsl did not have crew onboard for inspection. Logs did not indicate any drills completed. Vsl must run all drills, MOB, abandon ship and fire drill prior to sail.
Action required: 705 - Other - as specified
Resolved 16 May 2007
Lifesaving
Issued 17 June 1996 Resolved
Prove proper operation of Dead Man Jacking system.
Condition: Unknown
Due 17 July 1996
Resolved 19 June 1996
Engineering
Issued 17 June 1996 Resolved
PROVE PROPER OPERATION OF REMOTE FUEL OIL SHUT DOWNS.
Condition: Unknown
Due 17 July 1996
Resolved 24 June 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.