SILVER DOLPHIN

Built
1980
Last inspected
13 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 April 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB8370
183766
Flag
UNITED STATES
Maury page id
psix-183766

Documentation record

Registered dimensions (L × B × D)31.7 ft × 13.2 ft × 5.7 ft
Registered tonnagegross 15 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHOMPSON TRAWLERS INC · TITUSVILLE · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORWALK, CT
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 31 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 15 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

13 April 2026 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8357990
25 October 2024 Administrative Inspection · Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8024684
24 January 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7844865
7 November 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7813656
18 October 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7581058
19 January 2022 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7378688
19 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7318628
5 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7062332
30 December 2019 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6876743
29 October 2019 Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6840988
7 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6577537
31 January 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6347237
9 November 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6304232
8 November 2016 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6037640
18 March 2016 Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5836119

Deficiency record · 48

10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 May 2025 Resolved
Outdated light light, coast pilot, and no Coast Guard Navigation Rules onboard. Provide evidence of replacements.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2025
Resolution: Vessel has updated nav publications onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2025 Resolved
Found leaking raw water hose from strainer to the engine. Replace with new hose.
Action required: 10 - Deficiency Rectified
Resolved 5 May 2025
Resolution: Replaced hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2025 Resolved
Engine room ventilation not able to be secured during fire. Provide evidence that the ventilation can be secured closed.
Action required: 10 - Deficiency Rectified
Resolved 5 May 2025
Resolution: Vent can be closed during fire.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 November 2024 Resolved
Roof of vessel is leaking outside water. Remove rotted portions of the roof and replace with new material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: Rotted wood removed and replaced with new plywood and sealed. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2024 Resolved
Remove damaged fire retarded insulation in engine compartment. Replaced with approved material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: Replaced damaged insulation and secured hanging insulation. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2024 Resolved
Underwater light has a splice int he electrical line. Remove the light or replace with a solid piece of cable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: New cable and lights installed where existing splice located. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2024 Resolved
Low pressure steering system has a temporary fix installed. Provide repair proposal and repair prior to operating in the spring.
Action required: 705 - Other - as specified
Resolved 8 April 2025
Resolution: Removed old leaking piping and replaced with J-1942 factory fittings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2023 Resolved
Exhaust leaking in the engine room. Find the cause and remedy the leak.
Action required: 705 - Other - as specified
Due 21 November 2023
Resolved 22 November 2024
Resolution: No exhaust leak found after removed lagging. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2023 Resolved
Port fuel shutoffs doesn't remain closed when pulled. The valve need to stay in the closed position when pulled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2023 Resolved
Battery cable exposed on the helm stations. Each conductor must be in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2023
Resolved 17 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 November 2023 Resolved
Life float line has erroded away. Replace line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023 Resolved
First aid doesn't have all required items. Get the required items from 46 CFR 160.041-4(b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
Resolution: Replaced expired first aid supplies.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2023 Resolved
Battery box is filled with water. Box needs to clean and dry.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2023 Resolved
Engine room supply and exhaust cant be closed. Has to be able to be closed in the event of engine room fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2023 Resolved
Electrical connections on mast exposed. Wires need to be in an enclosure.
Action required: 705 - Other - as specified
Resolved 17 May 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 18 October 2022 Resolved
Aft main deck has a crack exposed on the weather deck. Leaking water into the engine room. Provide repair proposal and remove cracked deck for further inspection.
Action required: 705 - Other - as specified
Resolved 23 April 2023
Resolution: Deck has been repaired to our satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2022 Resolved
Adult life jacket storage not legible. Adult life jackets storage needs to be labeled properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 29 October 2022
Resolution: Sent pitcure of correct labelling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
Vent shutdowns to engine room space don't fully close. Vents need to be able to close all the way and stay secured when closed.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2021
Resolved 19 April 2022
Resolution: Engine room shutdown is operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
Exhaust pipe section missing wrapped lagging. All exhaust piping need to be wrapped properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2021
Resolved 19 April 2022
Resolution: Exhaust pipe wrapped with proper lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 October 2020 Resolved
Life Float painter line is required to be in good working order. Current painter line is frayed and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O installed new painter line to replace existing.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 October 2020 Resolved
Life Float required to have working lifelines in good working order. Current lifelines are frayed and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O replace and installed new life lines on Life Float.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 October 2020 Resolved
Life Float weak link needs to be permanently affixed to the vessel. Upon inspection the weak link can detached from its fixed location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O made weak link permanently fixed to vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2020 Resolved
Vessel is required 3 fire buckets onboard. Currently vessel had 5 gallon fire buckets not labelled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O has the required fire buckets onboard vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of valid FCC Safety Radiotelephony Certificate. Current certificate expires 11/4/2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 29 June 2020
Resolution: O/O provided current FCC safety certificate.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 October 2019 Resolved
Provide copy of annual fire fighting servicing. Current tag expires 11/30/2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has had all fire extinguishers and pre-engineered system maintenance by certified servicing agency.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 October 2019 Resolved
Repair/replace fwd bilge auto switch. This was not working upon inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has working fwd bilge auto switch.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 October 2019 Resolved
Provide proper "not under command" lights. (red-white-red). Currently all white lights. NAVRULES #27 (e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has installed new nav lights that meet the NAVRULE#27 red-white-red.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 October 2019 Resolved
Provide new line on waterlight attached to lifefloat. Line needs to be no less than 18ft. Line was detached and ruined. Vessel restricted to w/in 1 mile from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2019
Resolved 2 November 2019
Resolution: provided
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019 Resolved
Clean up dead end wiring in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has removed dead end wire and organized existing cables.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019 Resolved
Clean rear terminals/connections in engine room and provide drip shield.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has cleaned up battery terminals and installed drip shield.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 October 2019 Resolved
Provide eye wash for 1st Aid Kit. Current eye wash is expired (2018).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has provided eye wash for first aid kit.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019 Resolved
Clean up mast wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: Mast wiring has been cleaned and organized.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of valid proof of enrollment in a Drug and Alcohol Consortium. Current proof expired 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: provided. Expires 6/30/2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide a list of covered employees under your drug and alcohol consortium.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide proof of submission from the consortium for your 2018 MIS Submission.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: Provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of the last random drug test completed by covered employee.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 6 November 2019
Resolution: provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of last pre-employment test for a covered employee.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: provided
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 November 2018 Resolved
Inspect fire suppression system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2018
Resolved 9 November 2018
Resolution: Fire system inspected.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 November 2018 Resolved
Provide COD
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2018
Resolved 23 January 2019
Resolution: COD provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2018 Resolved
Repair/secure AFT bilge float switch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2018
Resolved 9 November 2018
Resolution: float switch secured.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 November 2018 Resolved
Remove water from battery compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2018
Resolved 23 January 2019
Resolution: water removed
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 31 January 2018 Resolved
Properly install cable and cable housing.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 18 April 2018
Resolution: Cable pin attached.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 November 2017 Resolved
Label child lift jacket locker with number of life jackets.
Due 9 December 2017
Resolved 18 April 2018
Resolution: Life jacket locker labeled.
Lifesaving › Hand Flares › Expired
Issued 9 November 2017 Resolved
Replace 03 night flres.
Due 9 December 2017
Resolved 18 April 2018
Resolution: Flares installed.
Engineering › Bilge Water Management System › Pump
Issued 9 November 2017 Resolved
Repair/replace FWD Bilge pump and high water alarm
Due 9 December 2017
Resolved 18 April 2018
Resolution: Pump installed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 9 November 2017 Resolved
De-cludder vessel.
Due 9 December 2017
Resolved 18 April 2018
Resolution: Vessel cleaned up.
Construction/Loadline › Structures › Deck Plating
Issued 18 March 2016 Resolved
Replace rotted wood located Port side aft of hatch in transom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 25 April 2016
Resolution: Rotted wood located Port side aft of hatch in transom has been replaced.
Engineering › Bilge Water Management System › Not Installed
Issued 18 March 2016 Resolved
Secure high water alarm and bilge pump float switch in engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 25 April 2016
Resolution: High water alarm and bilge pump float switch in engine room has been secured.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.