SILVER DOLPHIN

SILVER DOLPHIN is a 1980 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1989, most recently in April 2026, along with 137 deficiencies, 1 operational control and 1 casualty investigation in 2026.

Records from 1989 to 2026. Most recent: casualty investigation, 11 July 2026.

Built
1980
Last inspected
13 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8370
183766
Flag
UNITED STATES
366957520
Maury page id
psix-183766

Inspections, by type

…with no type recorded4
Years with a record 32 calendar years (1989–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.7 ft × 13.2 ft × 5.7 ft
Registered tonnagegross 15 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHOMPSON TRAWLERS INC · TITUSVILLE · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORWALK, CT
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 31 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB8370MMSI 366957520 · active · compulsorily equipped · granted 26 March 2024, expires 17 June 2034
WAASMMSI 366809050 · expired · compulsorily equipped · granted 23 April 2001, cancelled 25 June 2011
WQZ9649MMSI not assigned · cancelled · voluntarily equipped · granted 10 May 1995, cancelled 1 December 2000
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

13 April 2026 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8357990
25 October 2024 Administrative Inspection · Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8024684
24 January 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7844865
7 November 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7813656
18 October 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7581058
19 January 2022 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7378688
19 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7318628
5 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7062332
30 December 2019 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6876743
29 October 2019 Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6840988
7 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6577537
31 January 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6347237
9 November 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6304232
8 November 2016 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6037640
18 March 2016 Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5836119
19 October 2015 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5746653
27 December 2010 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3914173
25 October 2010 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3877420
6 October 2010 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3864993
1 July 2009 Type not recorded
No type recorded · Station Eatons Neck · USCG Northeast District (CGD-NE) · Activity 3521761
13 April 2009 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3451867
19 February 2009 Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3420345
15 December 2008 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3380064
24 November 2008 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3368277
11 December 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3113634
1 November 2007 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3091728
21 May 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2940041
4 May 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2922145
3 May 2007 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2921597
17 July 2006 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2715623
8 May 2006 Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2643428
12 December 2005 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2550045
20 September 2005 Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2497129
6 May 2005 Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2350613
17 March 2004 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2070688
13 August 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1660878
27 April 2001 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1471428
8 January 2001 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 825308
15 March 2000 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1397402
18 March 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1463445
7 December 1998 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1472737
10 March 1998 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1372153
3 April 1997 Deficiency Check · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1094006
4 December 1996 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 876989
27 March 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1078703
13 March 1996 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 885834
14 September 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1394369
2 September 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 3052
5 August 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 74641
15 March 1995 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1174906
2 December 1994 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1180800
17 March 1994 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1165309
8 April 1993 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 839559
24 February 1993 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1145343
4 August 1992 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 944969
17 March 1992 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 956278
18 April 1991 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 927693
12 April 1991 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 911884
9 April 1991 Deficiency Check · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 928459
15 February 1991 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1234646
24 September 1990 Drydock Extension
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1213799
4 April 1990 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 901283
3 April 1989 Initial Certification · Plan Review "T" Boat
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1224617
27 March 1989 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 911896

Deficiency record · 137

10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 May 2025 Resolved
Outdated light light, coast pilot, and no Coast Guard Navigation Rules onboard. Provide evidence of replacements.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2025
Resolution: Vessel has updated nav publications onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2025 Resolved
Found leaking raw water hose from strainer to the engine. Replace with new hose.
Action required: 10 - Deficiency Rectified
Resolved 5 May 2025
Resolution: Replaced hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2025 Resolved
Engine room ventilation not able to be secured during fire. Provide evidence that the ventilation can be secured closed.
Action required: 10 - Deficiency Rectified
Resolved 5 May 2025
Resolution: Vent can be closed during fire.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 November 2024 Resolved
Roof of vessel is leaking outside water. Remove rotted portions of the roof and replace with new material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: Rotted wood removed and replaced with new plywood and sealed. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2024 Resolved
Remove damaged fire retarded insulation in engine compartment. Replaced with approved material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: Replaced damaged insulation and secured hanging insulation. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2024 Resolved
Underwater light has a splice int he electrical line. Remove the light or replace with a solid piece of cable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: New cable and lights installed where existing splice located. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2024 Resolved
Low pressure steering system has a temporary fix installed. Provide repair proposal and repair prior to operating in the spring.
Action required: 705 - Other - as specified
Resolved 8 April 2025
Resolution: Removed old leaking piping and replaced with J-1942 factory fittings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2023 Resolved
Exhaust leaking in the engine room. Find the cause and remedy the leak.
Action required: 705 - Other - as specified
Due 21 November 2023
Resolved 22 November 2024
Resolution: No exhaust leak found after removed lagging. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2023 Resolved
Port fuel shutoffs doesn't remain closed when pulled. The valve need to stay in the closed position when pulled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2023 Resolved
Battery cable exposed on the helm stations. Each conductor must be in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2023
Resolved 17 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 November 2023 Resolved
Life float line has erroded away. Replace line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023 Resolved
First aid doesn't have all required items. Get the required items from 46 CFR 160.041-4(b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
Resolution: Replaced expired first aid supplies.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2023 Resolved
Battery box is filled with water. Box needs to clean and dry.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2023 Resolved
Engine room supply and exhaust cant be closed. Has to be able to be closed in the event of engine room fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2023 Resolved
Electrical connections on mast exposed. Wires need to be in an enclosure.
Action required: 705 - Other - as specified
Resolved 17 May 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 18 October 2022 Resolved
Aft main deck has a crack exposed on the weather deck. Leaking water into the engine room. Provide repair proposal and remove cracked deck for further inspection.
Action required: 705 - Other - as specified
Resolved 23 April 2023
Resolution: Deck has been repaired to our satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2022 Resolved
Adult life jacket storage not legible. Adult life jackets storage needs to be labeled properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 29 October 2022
Resolution: Sent pitcure of correct labelling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
Vent shutdowns to engine room space don't fully close. Vents need to be able to close all the way and stay secured when closed.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2021
Resolved 19 April 2022
Resolution: Engine room shutdown is operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
Exhaust pipe section missing wrapped lagging. All exhaust piping need to be wrapped properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2021
Resolved 19 April 2022
Resolution: Exhaust pipe wrapped with proper lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 October 2020 Resolved
Life Float painter line is required to be in good working order. Current painter line is frayed and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O installed new painter line to replace existing.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 October 2020 Resolved
Life Float required to have working lifelines in good working order. Current lifelines are frayed and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O replace and installed new life lines on Life Float.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 October 2020 Resolved
Life Float weak link needs to be permanently affixed to the vessel. Upon inspection the weak link can detached from its fixed location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O made weak link permanently fixed to vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2020 Resolved
Vessel is required 3 fire buckets onboard. Currently vessel had 5 gallon fire buckets not labelled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 18 November 2020
Resolution: O/O has the required fire buckets onboard vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of valid FCC Safety Radiotelephony Certificate. Current certificate expires 11/4/2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 29 June 2020
Resolution: O/O provided current FCC safety certificate.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 October 2019 Resolved
Provide copy of annual fire fighting servicing. Current tag expires 11/30/2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has had all fire extinguishers and pre-engineered system maintenance by certified servicing agency.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 October 2019 Resolved
Repair/replace fwd bilge auto switch. This was not working upon inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has working fwd bilge auto switch.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 October 2019 Resolved
Provide proper "not under command" lights. (red-white-red). Currently all white lights. NAVRULES #27 (e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has installed new nav lights that meet the NAVRULE#27 red-white-red.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 October 2019 Resolved
Provide new line on waterlight attached to lifefloat. Line needs to be no less than 18ft. Line was detached and ruined. Vessel restricted to w/in 1 mile from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2019
Resolved 2 November 2019
Resolution: provided
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019 Resolved
Clean up dead end wiring in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has removed dead end wire and organized existing cables.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019 Resolved
Clean rear terminals/connections in engine room and provide drip shield.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has cleaned up battery terminals and installed drip shield.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 October 2019 Resolved
Provide eye wash for 1st Aid Kit. Current eye wash is expired (2018).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: O/O has provided eye wash for first aid kit.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019 Resolved
Clean up mast wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 29 June 2020
Resolution: Mast wiring has been cleaned and organized.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of valid proof of enrollment in a Drug and Alcohol Consortium. Current proof expired 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: provided. Expires 6/30/2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide a list of covered employees under your drug and alcohol consortium.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide proof of submission from the consortium for your 2018 MIS Submission.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: Provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of the last random drug test completed by covered employee.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 6 November 2019
Resolution: provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 October 2019 Resolved
Provide copy of last pre-employment test for a covered employee.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 November 2019
Resolution: provided
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 November 2018 Resolved
Inspect fire suppression system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2018
Resolved 9 November 2018
Resolution: Fire system inspected.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 November 2018 Resolved
Provide COD
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2018
Resolved 23 January 2019
Resolution: COD provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2018 Resolved
Repair/secure AFT bilge float switch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2018
Resolved 9 November 2018
Resolution: float switch secured.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 November 2018 Resolved
Remove water from battery compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2018
Resolved 23 January 2019
Resolution: water removed
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 31 January 2018 Resolved
Properly install cable and cable housing.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 18 April 2018
Resolution: Cable pin attached.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 November 2017 Resolved
Label child lift jacket locker with number of life jackets.
Due 9 December 2017
Resolved 18 April 2018
Resolution: Life jacket locker labeled.
Lifesaving › Hand Flares › Expired
Issued 9 November 2017 Resolved
Replace 03 night flres.
Due 9 December 2017
Resolved 18 April 2018
Resolution: Flares installed.
Engineering › Bilge Water Management System › Pump
Issued 9 November 2017 Resolved
Repair/replace FWD Bilge pump and high water alarm
Due 9 December 2017
Resolved 18 April 2018
Resolution: Pump installed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 9 November 2017 Resolved
De-cludder vessel.
Due 9 December 2017
Resolved 18 April 2018
Resolution: Vessel cleaned up.
Construction/Loadline › Structures › Deck Plating
Issued 18 March 2016 Resolved
Replace rotted wood located Port side aft of hatch in transom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 25 April 2016
Resolution: Rotted wood located Port side aft of hatch in transom has been replaced.
Engineering › Bilge Water Management System › Not Installed
Issued 18 March 2016 Resolved
Secure high water alarm and bilge pump float switch in engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 25 April 2016
Resolution: High water alarm and bilge pump float switch in engine room has been secured.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 19 October 2015 Resolved
Replace velcro closure on fire dampers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2016
Resolution: Velcro has been replaced.
Engineering › Steering Gear System › Piping
Issued 19 October 2015 Resolved
Seal leaks in hydraulic steering tubing behind helm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 November 2016
Resolution: System no longer leaking.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 October 2015 Resolved
Remove excess items from (de-junk) boat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2016
Resolution: Boat de-junkified.
Lifesaving › Lifefloat › Painter
Issued 19 October 2015 Resolved
Replace lifefloat painter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 18 March 2016
Resolution: Sea painter has been replaced.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 October 2010 Resolved
Provide updated Coast Pilot, CG Light List, Tide Tables and Currents.
Due 20 October 2010
Resolved 22 October 2010
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 October 2010 Resolved
Replace batteries in strobes unless within expiration limits as marked by manufacturer. (noted 2008 on inspected battery)
Due 20 October 2010
Resolved 22 October 2010
Engineering › Steering Gear System › Yoke
Issued 7 October 2010 Resolved
Service steering gear to ensure operability of emergency tiller.
Due 20 October 2010
Resolved 22 October 2010
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 7 October 2010 Resolved
Lubricate/service emergency fuel cut-off valve on starboard side.
Due 20 October 2010
Resolved 22 October 2010
Lifesaving › Lifejacket/PFD (Type IV) › Lights
Issued 1 November 2007 Resolved
Renew water light on ring bouy.
Condition: Improper/Lack of Maintenance
Due 2 November 2007
Resolved 2 November 2007
Resolution: Water light replaced.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 1 November 2007 Resolved
Re-thimble anchor line.
Condition: Damaged By Earlier Event
Due 14 November 2007
Resolved 11 December 2007
Resolution: Anchor line re-thimbled.
Engineering › Lubricating Oil Service System › Hose
Issued 1 November 2007 Resolved
Provide additional hose clamp for seawater hose at L/O cooler.
Condition: Improper/Lack of Maintenance
Due 14 November 2007
Resolved 11 December 2007
Resolution: Additional hose clamps provided.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 November 2007 Resolved
Remove excessive flammable equipment/liquids from vessel.
Due 14 November 2007
Resolved 11 December 2007
Resolution: Excess flammable equipment removed.
Electrical › Electrical Distribution System (service) › Fuse
Issued 1 November 2007 Resolved
Remove build up of dust on main fuses and wiring in engine room.
Condition: Improper/Lack of Maintenance
Due 14 November 2007
Resolved 11 December 2007
Resolution: Dust buildup removed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 May 2007 Resolved
Provide proof of enrollment in an approved drug testing consortium.
Condition: Improper/Lack of Maintenance
Due 8 May 2007
Resolved 4 May 2007
Resolution: Proof of enrollment in a drug testing consortium provided.
Engineering › Fuel Oil Service System › Valve
Issued 3 May 2007 Resolved
Prove proper operation of port emergency fuel shut off.
Due 8 May 2007
Resolved 4 May 2007
Resolution: Handle repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2007 Resolved
Provide eyewash and asprin for first aid kit.
Due 8 May 2007
Resolved 4 May 2007
Resolution: Eyewash and asprin provided.
Engineering › Bilge Water Management System › Pump
Issued 17 July 2006 Resolved
Clear debris from all bilge suctions and repair pump strainer in mid compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2006
Resolved 26 July 2006
Resolution: Debris cleared.
Engineering › Steering Gear System › Rudder Bearing
Issued 17 July 2006 Resolved
Repack rudder post.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2006
Resolution: Rudder stuffing box tightened and tested satisfactory.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 17 July 2006 Resolved
Renew shaft cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2006
Resolved 26 July 2006
Resolution: Shaft cutlass bearing renewed.
Engineering › Bilge Water Management System › Pump
Issued 17 July 2006 Resolved
Provide sufficient hand bilge pump with hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2006
Resolved 26 July 2006
Resolution: Proper hand pump provided.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 July 2006 Resolved
Secure all hand rails forward.
Condition: Improper/Lack of Maintenance
Due 31 July 2006
Resolved 26 July 2006
Resolution: Handrails secured.
Construction/Loadline › Hull › Stringer
Issued 17 July 2006 Resolved
Find source of water leak in engine room and replace wasted deck stringer.
Condition: Improper/Lack of Maintenance
Due 30 September 2006
Resolved 4 April 2007
Resolution: Deck stringer has been replaced.
Construction/Loadline › Structures › Deck Plating
Issued 17 July 2006 Resolved
Find source of leak and renew rotted deck and deck supports above port side lazzerrette.
Condition: Improper/Lack of Maintenance
Due 30 September 2006
Resolved 4 April 2007
Resolution: Deck and supports have been repaired.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 8 May 2006 Resolved
USCG marine inspector must conduct plan verification for approved washbasin.
Condition: Placed in Improper Service
Due 8 June 2006
Resolved 3 May 2007
Resolution: Plan verification conducted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 December 2005 Resolved
Prove proper operation and adjustment of stbd running light and masthead light.
Condition: Improper Installation
Due 12 January 2006
Resolved 16 December 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 December 2005 Resolved
Replace all expired meds in first aid kit.
Due 5 January 2006
Resolved 16 December 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 December 2005 Resolved
Provide capture device for lazzarette deck hatch.
Condition: Unknown
Due 12 January 2006
Resolved 16 December 2005
Construction/Loadline › Hull › Side Shell
Issued 12 December 2005 Resolved
Properly cap overboard in E/R portside.
Condition: Improper/Lack of Maintenance
Due 12 January 2006
Resolved 30 December 2005
Resolution: Completed.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 12 December 2005 Resolved
Clean MDE Raycor fuel filter.
Due 12 January 2006
Resolved 16 December 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2005 Resolved
USCG marine inspector to complete as-built verification of new anchor windlass motor circuit.
Condition: Unknown
Due 6 June 2005
Resolved 26 September 2005
Resolution: Installation as per approved plans.
Documentation › Certificates/Documents › Stability Letter
Issued 17 March 2004 Resolved
Provide USCG copy of original stability letter and post same on vessel prior to issuance of COI.
Condition: Unknown
Due 24 December 2004
Resolved 3 December 2004
Resolution: Completed.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 March 2004 Resolved
Provide copy of DAPI program for USCG review.
Condition: Unknown
Due 24 December 2004
Resolved 3 December 2004
Resolution: Completed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 March 2004 Resolved
Renew expired meds in first aid kit.
Condition: Improper/Lack of Maintenance
Due 24 December 2004
Resolved 3 December 2004
Resolution: Completed.
Engineering › Bilge Water Management System › Not Operational
Issued 17 March 2004 Resolved
Prove proper operaton of bilge alarm system.
Condition: Improper/Lack of Maintenance
Due 24 December 2004
Resolved 3 December 2004
Resolution: Test sat.
Construction/Loadline › Structures › Superstructure
Issued 17 March 2004 Resolved
Tighten/secure all deck railings as needed.
Condition: Improper/Lack of Maintenance
Due 24 December 2004
Resolved 3 December 2004
Resolution: Completed.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 17 March 2004 Resolved
Provide current deviation table for magnetic compass.
Condition: Unknown
Due 24 December 2004
Resolved 3 December 2004
Resolution: Completed.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 March 2004 Resolved
Provide up-to-date US Coast Pilot and tides/current tables.
Condition: Unknown
Due 24 December 2004
Resolved 3 December 2004
Resolution: Completed.
Lifesaving › Buoyant Apparatus
Issued 13 August 2002 Resolved
Renew broken Lifering. LEGACY COMPONENT DESC: Life ring
Condition: Unknown
Due 18 August 2002
Resolved 26 August 2002
Resolution: New Ring on board
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 August 2002 Resolved
Provide metal wire mounts as per regulations
Due 18 August 2002
Resolved 24 November 2004
Resolution: Complete.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 August 2002 Resolved
Provide cover for antenna grounding plate by cabin main entrance
Condition: Unknown
Due 18 August 2002
Resolved 24 November 2004
Resolution: Plate removed as well as SSB radio.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 August 2002 Resolved
properly secure all dead end wires in way of engineroom
Due 18 August 2002
Resolved 24 November 2004
Resolution: Complete.
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 August 2002 Resolved
Provide pipe cap for sea suction through hull valve where the firepump/bilge pump was removed fwd stbd side of the engineroom.
Condition: Improper Installation
Due 18 August 2002
Resolved 13 August 2002
Resolution: Through hull valve properly capped.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 August 2002 Resolved
Hydrostatic release expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2002
Resolution: new release on board
Engineering › Fuel Oil Service System › Filter
Issued 13 August 2002 Resolved
Properly install fuel filter flame bowl
Condition: Improper Installation
Due 18 August 2002
Resolved 13 August 2002
Resolution: Corrected.
Engineering › Fuel Oil Service System › Hose
Issued 13 August 2002 Resolved
Install proper fuel line in way of supply to secondary filter on Main Engine port side aft.
Condition: Improper Installation
Due 18 August 2002
Resolved 1 December 2004
Resolution: Complete.
Engineering › Fuel Oil Service System › Valve
Issued 13 August 2002 Resolved
Prove proper operation of Emergency Fuel shutoff valves.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2002
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 August 2002 Resolved
Prove existence of proper Certificate of Documentation for the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2002
Resolution: Owner had removed document for bank purposes. Provided to the attending marine inspector.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 13 August 2002 Resolved
Provide 5 smoke or red flares to replace outdated items.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2002
Resolution: Vessel had 5 out dated smoke flares on board. Owner replaced.
Lifesaving › Lifejacket/PFD (General)
Issued 13 August 2002 Resolved
Provide life jacket donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2002
Resolution: Owner obtained and posted.
Engineering › Bilge Water Management System › Piping
Issued 13 August 2002 Resolved
Properly cap/plug off old bilge eductor system running fwd and aft of engineroom. Two through bulkhead penetrations in the aft engineroom and one forward bulkhead of the engineroom. Total of 3.
Condition: Improper Installation
Due 18 August 2002
Resolved 24 November 2004
Resolution: Complete.
Engineering › Bilge Water Management System › Pump
Issued 13 August 2002 Resolved
Provide proper rated bilge pump,piping and associated high level alarm for the fwd cabin compartment under the stairway in way of entrance to the cabin. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 18 August 2002
Resolved 24 November 2004
Resolution: Complete.
Construction/Loadline › Penetrations › Valve Flange
Issued 13 August 2002 Resolved
Provide proper hose and clamps for raw water supply to the bathroom from engineroom port side through hull valve.
Condition: Improper Installation
Due 18 August 2002
Resolved 24 November 2004
Resolution: Complete.
Construction/Loadline
Issued 27 April 2001 Resolved
PROVE PROPER OPERATION OF VISUAL SIGNAL ON HIGH LEVEL BILGE ALARM SYSTEM INACCORDANCE WITH 46CFR 182.530.
Condition: Unknown
Due 16 May 2001
Resolved 17 May 2001
Lifesaving
Issued 27 April 2001 Resolved
SECURE 60' LIFELINE TO RING BUOY IN ACCORDANCE WITH 46CFR 180.70 (C)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 May 2001
Resolved 17 May 2001
Lifesaving
Issued 15 March 2000 Resolved
RESPOOL MAIN LINE FOR LIFE FLOAT INSTALLING LINE CORRECTLY THROUGH CENTER RING. TO BE COMPLETED BEFORE CARRYING PASSENGERS.
Condition: Unknown
Due 16 March 2000
Resolved 13 April 2000
Lifesaving
Issued 15 March 2000 Resolved
PATCH ALL CRACKS IN LIFE FLOAT.
Condition: Unknown
Due 1 April 2000
Resolved 13 April 2000
Lifesaving
Issued 15 March 2000 Resolved
REPLACE 60 FT OF LINE ON RING BUOY.
Condition: Unknown
Due 16 March 2000
Resolved 13 April 2000
Fire Fighting
Issued 15 March 2000 Resolved
REPAIR HOLDING BRACKET FOR FIRE EXTINGUISHER AT ENTRANCE TO WHEEL HOUSE.
Condition: Unknown
Due 1 April 2000
Resolved 13 April 2000
Fire Fighting
Issued 15 March 2000 Resolved
LUBRICATE EMERGENCY SHUT OFF VENTS TO ENG ROOM AND REPLACE SEALING ELEMENT (GASKET).
Condition: Unknown
Due 16 March 2000
Resolved 13 April 2000
Fire Fighting
Issued 15 March 2000 Resolved
REPLACE EXISTING BOLTS ON EMERGENCY SHUT OFF VENTS WITH STAINLESS STEEL BOLTS.
Condition: Unknown
Due 1 April 2000
Resolved 13 April 2000
Lifesaving
Issued 15 March 2000 Resolved
MAINTAIN LOG FOR EPIRB TESTS.
Condition: Unknown
Due 1 April 2000
Resolved 13 April 2000
Construction/Loadline
Issued 15 March 2000 Resolved
INSTALL HIGH LEVEL BILGE ALARM WARNING LIGHT AT OPERATING STATION.
Condition: Unknown
Due 16 March 2000
Resolved 13 April 2000
Documentation
Issued 18 March 1999 Resolved
Obtain and maintain a current training log book for drills and training.
Condition: Unknown
Due 24 March 1999
Resolved 26 March 1999
Fire Fighting
Issued 18 March 1999 Resolved
Install smoke detection system as per 46 CFR 181.450.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Fire Fighting
Issued 18 March 1999 Resolved
Provide servicing report for fire extinguishers showing that_x001C_ they were all serviced.
Condition: Unknown
Due 24 May 1999
Resolved 26 March 1999
Unknown
Issued 18 March 1999 Resolved
Provide an approved first aid kit O/B.
Condition: Unknown
Due 24 May 1999
Resolved 26 March 1999
Electrical
Issued 10 March 1998 Resolved
REPLACE OR REMOVE AFT LIGHT FIXTURE.
Condition: Unknown
Due 10 April 1998
Resolved 20 March 1998
Fire Fighting
Issued 10 March 1998 Resolved
REPLACE SEAL IN ENGINE DRIVEN FIRE PUMP AND PROVE PROPER OPERATION TO MARINE INSPECTOR.
Condition: Unknown
Due 10 April 1998
Resolved 20 March 1998
Navigation
Issued 10 March 1998 Resolved
PROVIDE LOCKING FASTENER ON STEERING SYSTEM CONNECTION.
Condition: Unknown
Due 10 April 1998
Resolved 20 March 1998
Lifesaving
Issued 3 April 1997 Resolved
PROVIDE LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Construction/Loadline
Issued 3 April 1997 Resolved
PROVIDE BILGE SUCTION SCREEN IN AFT STEERING.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 3 April 1997 Resolved
PROVIDE ONE ADULT LIFE PRESERVER. VSL RESTRICTED TO 33 ADULTS UNTIL CORRECTED.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 3 April 1997 Resolved
PROVIDE PROPER REFLECTIVE TAPE FOR LIFE JACKETS AS NEEDED.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Navigation
Issued 3 April 1997 Resolved
PROVIDE ALL DOCUMENTS AS REQUIRED BY 46 CFR 184.420.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Documentation
Issued 13 March 1996 Resolved
PROVIDE AN UPDATED FCC STATION LICENSE.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Engineering
Issued 13 March 1996 Resolved
REPLACE VALVE HANDLE AND FREE VALVE FOR RAW WATER LINE (NOT THE SEA VALVE).
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Engineering
Issued 13 March 1996 Resolved
REPLACE CRACKED FLEXIBLE FUEL HOSE WITH USCG APPROVED FUEL HOSE.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Electrical
Issued 13 March 1996 Resolved
REPLACE TWO BROKEN LIGHT FIXTURE GLOBES IN THE ENGINE ROOM.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Documentation
Issued 13 March 1996 Resolved
PROVIDE A WRITTEN DRUG TEST POLICY.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Lifesaving
Issued 13 March 1996 Resolved
REPAIR/REPLACE ONE CHILD LIFE PRESERVER LIGHT. DO NOT CARRY MORE THAN THREECHILDREN UNTIL CORREDTED.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Engineering
Issued 14 September 1995 Resolved
REPAIR AND PROVE PROPER OPERATION OF MAIN DIESEL ENGINE. VESSEL RESTRICTEDFROM OPERATION UNTIL EXAMINED TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 October 1995
Resolved 14 September 1995
Lifesaving
Issued 9 April 1991 Resolved
SHOW PROPER OPERATION OF LIFE FLOAT WATERLIGHT PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Engineering
Issued 9 April 1991 Resolved
PROVIDE FLAME SCREENS ON PORT AND STARBOARD FUEL VENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Documentation
Issued 9 April 1991 Resolved
PROVIDE CURRENT FCC RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Engineering
Issued 9 April 1991 Resolved
RENEW WASTED LAGGING ON ENGINE EXHAUST._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Lifesaving
Issued 9 April 1991 Resolved
VESSEL IS RESTRICTED TO 33 TOTAL PERSONS UNTIL REFLECTIVE TAPE IS REPAIRED ON 1 ADULT PFD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Fire Fighting
Issued 4 April 1990 Resolved
PROVIDE AUTOMATIC ENGINE SHUTDOWN FOR THE ENGINE WHEN HALON IS DISCHARGED
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Navigation
Issued 4 April 1990 Resolved
PROVE THAT NAVIGATIONAL LIGHTS MEET 1972 COLREGS REQUIREMENTS
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Construction/Loadline
Issued 4 April 1990 Resolved
PROVIDE CABLE TO CLOSE OFF GAP IN RAILING AT BOW.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990

Casualty record · 1

11 July 2026Routine · role: Involved in a Marine Casualty · 1 injured · activity 8448536
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.